Full gigabit 6-port managed bt industrial PoE switch

Model
Nature of the Manufacturer
Manufacturer
Product Category
Industrial PoE Switch
Place of Origin
City, Province
Overview
L2+ managed bt industrial PoE switch with 4*10/100/1000M bt PoE ports and 2*100/1000M uplink SFP ports. Port 1- 4 can support IEEE802.3af/at/bt PoE standard. It can support dual DC power input and DIN rail mounting.
Product Details


OVERVIEW


ONV-IPS33064PFM-bt is a full Gigabit managed bt industrial PoE switch independently developed by ONV. It has 4*10/100/1000M bt PoE ports and 2*100/1000M SFP fiber slot ports. Port 1-4 can support IEEE802.3af/at/bt PoE standard. Single-port PoE power output is 90W. As a PoE power supply device, it can automatically detect and recognize the power-receiving equipment that meets the standard and supply power through the network cable. It provides stable and safe terminals for PTZ network domes, high-power wireless AP, high-power network multimedia speakers, and high-power POE lighting, etc. through a network cable to meet the network environment that needs high-density PoE power supply. It is suitable for intelligent transportation, rail transit, electric power, mining, metallurgy and green energy. Industrial scenes such as construction set up a cost-effective and stable communication network.

The ONV-IPS33064PFM-bt has L2+ full network management function, support IPV4/ IPV6 management, static route full line rate forwarding, security protection mechanism, ACL/QoS policy and VLAN, and is easy to manage and maintain. Support multiple network redundancy protocols STP/RSTP/MSTP (<50ms) and (ITU-T G.8032) ERPS (<20ms) to improve link backup and network reliability. When one-way network fails, communication can be quickly restored to ensure important Uninterrupted communication for applications. According to the actual application requirements, you can configure multiple application services such as PoE power management, port traffic control, VLAN division, and SNMP through the Web network management mode.

 

FEATURE


Gigabit access, SFP fiber port uplink

◇ Support Gigabit Ethernet port and Gigabit SFP port combination, which enables users to flexibly build networking to meet the needs of various scenarios.

◇ Support non-blocking wire-speed forwarding.

◇ Support full-duplex based on IEEE802.3x and half-duplex based on Backpressure.

 

Intelligent PoE power supply

◇ 4*10/100/1000Base-T RJ45 ports can support bt PoE power supply, meeting the demand for super high power PoE power supply in various scenarios.

◇ IEEE802.3af/at PoE standard, without damaging non-PoE devices.

◇ Priority system for PoE port, it will supply power to the high priority level port first when the power budget is insufficient and avoid overwork of the device.

◇ Set on the Web network management interface to control the PoE port power supply based on the user-defined time period.

◇ Customize the output power of the PoE port, the output power range covers the 5-90W PoE terminal load, providing a more practical configuration for the flexible use and control of PoE.

 

PoE network management and fast Ring function

◇ IEEE802.1Q VLAN, flexible VLAN division,Voice VLAN and QinQ configuration.

◇ QoS, Priority mode based on 802.1P, Port & DSCP, queue scheduling algorithm including EQU, SP, WRR & SP+WRR.

◇ ALC, filter data packet through configuring matching rules, processing operation & time permission, and provide flexible and safe access control.

◇ IGMP V1/V2 and IGMP Snooping.

◇ ERPS/STP/RSTP/MSTP.

◇ Static and dynamic aggregation.

 

Security

◇ 802.1X authentication.

◇ Port isolation,Storm control.

◇ IP-MAC-VLAN-Port binding.

 

Stable and reliable

◇ Low power consumption, fan-less design, aluminum shell.

◇ CCC, CE, FCC, RoHS.

◇ The user-friendly panel can show the device status through the LED indicator of PWR, SYS, Link, L/A, PoE.

 

One-stop remote control and management

◇ Web management, CLI command line (Console, Telnet), SNMP (V1/V2/V3).

◇ HTTPS, SSLV3, and SSHV1/V2.

◇ RMON, system log, LLDP, and port traffic statistics.

◇ CPU monitoring, memory monitoring, Ping test, and cable diagnose.

 

DIMENSION


6-port gigabit managed bt industrial PoE switch,bt industrial PoE switch


ORDERING INFORMATION


Model

Description

Recommended Power Supply

ONV-IPS33064PFM-bt

L2+ managed bt industrial PoE switch with 4*10/100/1000M bt PoE ports and 2*100/1000M uplink SFP ports. Port 1- 4 can support IEEE802.3af/at/bt PoE standard. It can support dual DC power input and DIN rail mounting.

240W

Note: Industrial PoE switch does no include the SFP optical module and power supply.


PACKING LIST


PACKING LIST

CONTENT

QTY

UNIT

6-port full gigabit managed bt industrial PoE switch

1

SET

RJ45-DB9 Line

1

PC

User Guide

1

PC

Warranty Card

1

PC

 

OPTICAL MODULE INFORMATION


Product

Model

Description

Unit

1.25G

Optical

Module

 

ONV-2630

SFP optical module, 1.25G, multi mode dual fiber 850nm, transmission distance: 550m, LC interface, support DDM function, support hot plug and pull.

PC

ONV-2632

SFP optical module, 1.25G, single-mode dual fiber 1310nm, transmission distance: 20km, LC interface, support DDM function, support hot plug and pull.

PC

ONV-2612-T

SFP optical module, 1.25G, single-mode single fiber TX1310nm/RX1550nm, transmission distance: 20km, LC interface, support DDM function, support hot plug and pull.

PC

ONV-2613-R

SFP optical module, 1.25G, single-mode single fiber TX1550nm/RX1310nm, transmission distance: 20km, LC interface, support DDM function, support hot plug and pull.

PC

2612-T-G

Industrial SFP optical module, 1.25G, single-mode single fiber TX1310nm/RX1550nm, transmission distance: 20km, LC interface, support DDM function, support hot plug and pull.

PC

2613-R-G

Industrial SFP optical module, 1.25G, single-mode single fiber TX1550nm/RX1310nm, transmission distance: 20km, LC interface, support DDM function, support hot plug and pull.

PC

ONV-2612-T-SC

SFP optical module, 1.25G, single-mode single fiber TX1310nm/RX1550nm, transmission distance: 20km, SC interface, support DDM function, support hot plug and pull.

PC

ONV-2613-R-SC

SFP optical module, 1.25G, single-mode single fiber TX1550nm/RX1310nm, transmission distance: 20km, SC interface, support DDM function, support hot plug and pull.

PC

Power Module

ONV-2633

1.25G SFP optical module transfers to 10/100/1000M RJ45 port.

PC

 

 

POWER SUPPLY


Product

Model

Description

Unit

240W DIN Rail Industrial Power Supply

GWS-DP240-48

Din Rail type 240W single set of output power supply;

Input Voltage:AC 100V~240V 50-60Hz,3A

Output Voltage:DC 48V 5A

Operation Temperature:-40℃—+70℃

PC

480W DIN Rail Industrial Power Supply

GWS-DP480-48

Din Rail type 480W single set of output power supply;

Input Voltage:AC 100V~240V 50-60Hz,5A

Output Voltage:DC 48V 10A

Operation Temperature:-40℃—+70℃

PC

 

RELATED PRODUCT


Model

Description

ONV-IPS33064P-bt

Unmanaged bt industrial PoE fiber switch with 6*10/100/1000M RJ45 ports. Port 1-4 can support IEEE802.3af/at/bt PoE standard. It can support dual DC power input and DIN rail mounting.

ONV-IPS33064PFG-bt

Unmanaged bt industrial PoE fiber switch with 5*10/100/1000M RJ45 ports and 1*1000M SFP port. Port 1-4 can support IEEE802.3af/at/bt PoE standard. It can support dual DC power input and DIN rail mounting.

ONV-IPS33064PF-bt

Unmanaged bt industrial PoE fiber switch with 2*10/100/1000M RJ45 ports and 2*1000M SFP ports. Port 1-4 can support IEEE802.3af/at/bt PoE standard. It can support dual DC power input and DIN rail mounting.

ONV-IPS31064P-bt

Unmanaged bt industrial PoE switch with 6*10/100M RJ45 ports. Port 1-4 can support IEEE802.3af/at/bt PoE standard. It can support dual DC power input and DIN rail mounting.

ONV-IPS31064PFG-bt

Unmanaged bt industrial PoE fiber switch with 4*10/100M RJ45 ports and 1*10/100/1000M uplink RJ45 port and 1*1000M uplink SFP port. Port 1-4 can support IEEE802.3af/at/bt PoE standard. It can support dual DC power input and DIN rail mounting.

ONV-IPS31064PF-bt

Unmanaged bt industrial PoE fiber switch with 4*10/100M RJ45 ports and 2*155M uplink SFP ports. Port 1-4 can support IEEE802.3af/at/bt PoE standard. It can support dual DC  power input and DIN rail mounting.



TECHNICAL SPECIFICATION

 

Model

ONV-IPS33064PFM-bt

Interface Characteristics

Fixed Port

4*10/100/1000M bt PoE ports (Data/Power)

2*100/1000M uplink SFP slot ports (Data)

1 * RS232 console port(115200,N,8,1)

2 group of V+, V- redundant DC power interface (5 Pin Phoenix terminal)

Ethernet Port

Port 1-4 support 10/100/1000Base-T auto-sensing, full/half duplex MDI/MDI-X self-adaption

Twisted Pair Transmission

10BASE-T: Cat3,4,5 UTP(≤100 meter)

100BASE-TX: Cat5 or later UTP(≤100 meter)

1000BASE-T: Cat5e or later UTP(≤100 meter)

SFP Slot Port

Gigabit SFP optical fiber interface, default no include optical modules (optional single-mode / multi-mode, single fiber / dual fiber optical module. LC)

Optical Cable/ Distance

Multi-mode: 850nm /0 ~ 500M

Single-mode: 1310nm /0 ~ 40KM, 1550nm /0 ~ 120KM.

Chip Parameter

Network Management Type

L2+

Network Protocol

IEEE802.3 10BASE-T, IEEE802.3i 10Base-T, IEEE802.3u 100Base-TX

IEEE802.3ab 1000Base-T, IEEE802.3z 1000Base-X, IEEE802.3x

Forwarding Mode

Store and Forward(Full Wire Speed)

Switching Capacity

128Gbps

Forwarding

Rate@64byte

8.93Mpps

CPU

416MHz

DRAM

1G

FLASH

128M

MAC

8K

Buffer Memory

4M

Jumbo Frame

9.6K

LED Indicator

Power/ System: SYS (Green) , Network: Link (Yellow), fiber port: L/A (Green), PoE: PoE (Green)

Reset Switch

Yes, (Press and hold for 10 seconds and release, the switch will restore the factory settings)

PoE & Power Supply

PoE Port

Port 1- 4 @bt POE and backward compatible with IEEE802.3af/at

PoE Management

PoE working status

Delay start of power supply

PoE output priority configuration

Scheduling of PoE operation and time

Total power limit of PoE power supply

PoE output power allocation, on/off& af /at/bt

Power Supply Pin

Default 1/2 (+), 3/6 (-), 4/5 (+), 7/8 (-)

Max Power Per Port

90W, IEEE802.3af/at/bt

Power Consumption

Standby<8W, Full load<240W

Working Voltage

48-57VDC, 5 Pin industrial Phoenix terminal, support anti-reverse protection.

Power Supply

No, optional 48V/240W or 48V/480W industrial power supply

Physical Parameter

Operation TEMP / Humidity

-40~+80°C, 5%~90% RH Non condensing

Storage TEMP / Humidity

-40~+85°C, 5%~95% RH Non condensing

Dimension (L*W*H)

145*134.5*47.5mm

Net /Gross Weight

<0.6kg / <0.8kg

Installation

Desktop, 35mm DIN rail

Certification & Warranty

Lightning Protection

Lightning protection: 6KV 8/20us; Protection level: IP40

IEC61000-4-2(ESD):±8kV contact discharge,±15kV air discharge

IEC61000-4-3(RS):10V/m(80~1000MHz)

IEC61000-4-4(EFT): power cable:±4kV; data cable:±2kV

IEC61000-4-5(Surge):power cable:CM±4kV/DM±2kV; data cable:±4kV

IEC61000-4-6(radio frequency transmission):10V(150kHz~80MHz)

IEC61000-4-8(power frequency magnetic field):100A/m;1000A/m ,1s to 3s

IEC61000-4-9(pulsed magnet field):1000A/m

IEC61000-4-10(damped oscillation):30A/m  1MHz

IEC61000-4-12/18(Shock-wave):CM 2.5kV,DM 1kV

IEC61000-4-16(common-mode transmission):30V; 300V,1s

FCC Part 15/CISPR22(EN55022):Class B

IEC61000-6-2(Common Industrial Standard)

Mechanical Properties

IEC60068-2-6 (anti vibration), IEC60068-2-27 (anti shock)

IEC60068-2-32 (free fall)

Certification

CCC, CE mark, commercial, CE/LVD EN60950, FCC Part 15 Class B, RoHS

Warranty

5 years, lifelong maintenance.

Network Management Features

Interface

IEEE802.3X (Full-duplex)

Port temperature protection setting

Port green Ethernet Energy-saving setting

Broadcast storm control based on port speed

The speed limit of the message flow in the access port.

The minimum particle size is 64Kbps.

Layer 3 Features

L2+ network management ,IPV4/IPV6 management

L3 soft routing forwarding, Static route, Default route @ 128 pcs, APR @ 1024 pcs

VLAN

Voice VLAN, QinQ configuration

4K VLAN based on port, IEEE802.1q

Port configuration of Access, Trunk, Hybrid

VLAN based on MAC, VLAN based on the protocol

Port Aggregation

LACP, Static aggregation

Max 3 aggregation groups and 8 ports per group.

Spanning Tree

STP (IEEE802.1d), RSTP (IEEE802.1w), MSTP (IEEE802.1s)

Industrial Ring Network Protocol

G.8032 (ERPS), Recovery time less than 20ms

250 Ring at most, Max 250 devices per ring.

Multicast

MLD Snooping v1/v2,Multicast VLAN

IGMP Snooping v1/v2, Max 1024 multicast groups, Fast log out

Port Mirroring

Bidirectional data mirroring based on port

QoS

Flow-based Rate Limiting

Flow-based Packet Filtering

8*Output queues of each port

802.1p/DSCP priority mapping

Diff-Serv QoS,Priority Mark/Remark

Queue Scheduling Algorithm (SP, WRR, SP+WRR)

ACL

Port-based Issuing ACL,ACL based on port and VLAN

L2 to L4 packet filtering, matching first 80 bytes message. Provide ACL based on MAC, Destination MAC address, IP Source, Destination IP, IP Protocol Type, TCP/UDP Port, TCP/UDP Port Range, and VLAN, etc.

Security

IP-MAC-VLAN-Port binding

ARP inspection,Anti-DoS attack

AAA & RADIUS,MAC learning limit

Mac black holes,IP source protection

IEEE802.1X & MAC address authentication

Broadcast storm control,Backup for host datum

SSH 2.0,SSL,Port isolation,ARP message speed limit

User hierarchical management and password protection

DHCP

DHCP Client,DHCP Snooping,DHCP Server,DHCP Relay

Management

One-key recovery

Cable Diagnose,LLDP

Web Management (HTTPS)

NTP,System work log,Ping Test

CPU instant utilization status view

Console/AUX Modem/Telnet/SSH2.0 CLI

Download & Management on FTP, TFTP, Xmodem, SFTP,SNMP V1/V2C/V3

ONV NMS - smart network management system platform(LLDP+SNMP)

System

Category 5 Ethernet network cable

Web browser: Mozilla Firefox 2.5 or higher, Google browser chrome V42 or higher, Microsoft Internet Explorer10 or later;

TCP/IP, network adapter, and network operating system (such as Microsoft Windows, Linux, or Mac OS X) installed on each computer in a network

 

 



6-port gigabit managed bt industrial PoE switch,bt industrial PoE switch,industrial PoE switch