[Coil Installation]]
1. Rectangular installation
usually the detection coil should be rectangular. The two long sides are perpendicular to the direction of movement of the metal object, and the distance between each other is recommended to be 1 meter. The length of the long side depends on the width of the road, and usually the two ends are 0.3 meters to 1 meter narrower than the distance between the roads.
2. Inclined at 45 ° to install
In some cases, when it is necessary to detect a bicycle or motorcycle, the coil can be installed with an inclination of 45 degrees from the driving direction.
3.8-glyph installation
in some cases, when the road surface is wide (more than six meters) and the chassis of the vehicle is too high, this installation form can be used to disperse the detection points and improve the sensitivity.
This installation form can also be used for sliding door detection, but the coil must be close to the sliding door.

[number of turns of coil]]
In order to make the detector work in an optimal state, the inductance of the coil should be kept between 100uH-300uH. Under the condition that the inductance of the coil is unchanged, the number of turns of the coil has an important relationship with the circumference. The smaller the week length, the more turns. Generally, please refer to the following table:
| coil circumference | coil |
| below 3 meters | According to the actual situation, ensure that the inductance value is100 uH-200uH |
| 3-6 m | 5-6 turns |
| 6-10 m | 4-5 turns |
| 10 -- 25 m | 3 turns |
| over 25 meters | 2 turns |
Because various metal substances such as cable pipelines, steel bars, sewer covers and the like may be buried under the road, these will have a great impact on the actual inductance value of the coil, so the above data is for user reference only. During the actual construction, the user should use the inductance tester to actually test the inductance value of the ground induction coil to determine the actual number of turns of the construction, as long as the final inductance value of the coil is within a reasonable working range (e. g. between 100uH-300uH).
[Embedding method]]
(1) The coil is buried. First, a road cutter is used to cut out grooves on the road surface. Do a 45-degree chamfer on the four corners to prevent the sharp corners from damaging the coil cable. The width of the groove is generally 4 to 8mm and the depth is 30 to 50mm. At the same time, cut a slot for the coil lead to the roadside. However, it should be noted that the groove must be clean and free of water or other liquids. When winding the coil, the coil must be straightened, but not too tight and close to the bottom of the slot. After winding the coil, the twisted output lead is led out through the lead slot.
(2) During the winding process of the coil, an inductance tester shall be used to actually test the inductance value of the ground sensing coil and ensure that the inductance value of the coil is between 100uH-300uH. Otherwise, the number of turns of the coil should be adjusted.
(3) After the coil is buried, in order to strengthen the protection, a circle of nylon rope can be wound on the coil. Finally, seal the groove with asphalt or soft resin.