This kind of protective cover can be customized according to different application environments, and provide detailed drawings of the parts that need protection (local three-dimensional drawings are best)
Schematic diagram of technical parameters of organ shield
Lmax = Maximum stretch of protective cover
Lmin = minimum compression of the protective cover
S = stroke length
W = outer width of protective cover
Wi = inner width of protective cover
h = outer height of protective cover
hi = Inner height of protective cover
H = folding height of protective cover
n = fold of protective cover
D = cloth of protective cover
A = Protective cover skeleton
B = Flange at both ends of protective cover
H≤h-hi or H≤ (W-Wi) / 2 (symmetrical on both sides); if no special instructions, the flanges at both ends of the protective cover are made of Q235
Flexible organ shield order parameter table and receipt form
Parameter code Code
Parameter name Des
Parameter Value Figure
Test result (filled by our company) Test result by Kirus
Remark Remark
Description Remark
Lmax
Stretched out length of protective cover
Machine travel range ( required) Machine travel range (Not null)
Whether there is a lot of debris (optional) Scrap or not (Optional)
Order unit Company name
Shipping Address Company address
Contact Contact way
Shipping Method Shipping way
AirGround Freight Urgent Urgent Other____
The above data, CAD drawings or three-dimensional drawings of machine tools (.stp / .xt / .igs and other formats) must be provided when ordering, and our company can carry out evaluation design. Pls offer above demensions, CAD drawings or Machine 3D drawings (.stp or .xt or .igs), then our engineer can design
Such as ordering shield have special requirements, please fill in the remarks column contact or communicate directly with our company; if no requirement, in accordance with our standard production Pls remark if you have speical demand, or we will follow Krius regulation
Guide portions protection design must provide detailed drawings described Krius need detailed drawings for the protected pars of machine
If the orderer provides complete drawings of the protective cover, please indicate whether there is a margin between the guide rail and Pls mark are there some tolerance for guide rail and bellow cover if customer offer complete drawings
We will send the order issued together with the product at the time of delivery We will take the order details with goods shippment together
Basic shape
Shaped protective cover
Protective cover parameters
Lmax / Lmin / H
10
15
20
25
30
35
40
45
50
55
100
37
twenty two
19
16
13
13
13
13
13
10
150
53
31
twenty two
19
16
16
16
13
13
13
200
68
37
28
twenty two
19
19
16
16
16
13
250
83
46
34
28
twenty two
twenty two
19
19
16
16
300
99
53
37
31
25
twenty two
twenty two
19
19
16
350
114
62
43
34
28
25
twenty two
twenty two
19
19
400
130
68
50
37
31
28
25
twenty two
twenty two
19
450
145
77
53
43
34
31
28
25
twenty two
twenty two
500
160
83
59
46
37
34
31
28
25
twenty two
550
176
92
65
50
40
37
31
28
28
25
600
191
99
68
53
43
37
34
31
28
25
650
207
108
74
59
46
40
37
34
31
28
700
222
114
80
62
50
43
37
34
31
28
750
238
123
83
65
53
46
40
37
34
31
800
253
130
89
68
56
50
43
37
34
31
850
268
139
96
74
59
50
46
40
37
34
900
284
145
99
77
62
53
46
43
37
34
950
300
154
105
80
65
56
50
43
40
37
1000
315
160
111
83
68
59
53
46
43
37
1500
462
238
150
123
99
83
74
65
59
53
2000
622
315
213
160
130
111
96
83
77
68
2500
776
391
265
201
160
136
117
105
92
83
3000
930
462
315
238
191
160
139
123
111
99
3500
1084
545
367
277
222
188
160
142
127
114
4000
1238
622
419
315
253
213
185
160
145
130
4500
1392
699
462
355
284
238
207
182
160
145
5000
1546
776
521
391
315
265
228
201
179
160
The above data are all based on the parameters in Figure 2 and are the most value size
Lmax / Lmin / H
10
15
20
25
30
35
40
45
50
55
100
47
27
twenty three
18
15
15
15
15
15
11
150
67
39
27
twenty three
18
18
18
15
15
15
200
87
47
35
27
twenty three
twenty three
18
18
18
15
250
107
59
43
35
27
27
twenty three
twenty three
18
18
300
127
67
47
39
31
27
27
twenty three
twenty three
18
350
147
79
55
43
35
31
27
27
twenty three
twenty three
400
167
87
63
47
39
35
31
27
27
twenty three
450
187
99
67
55
43
39
35
31
27
27
500
208
107
75
59
47
43
39
35
31
27
550
228
119
83
63
51
47
39
35
35
31
600
248
127
87
67
55
47
43
39
35
31
650
268
139
95
75
59
51
47
43
39
35
700
289
147
103
79
63
55
47
43
39
35
750
309
159
107
83
67
59
51
47
43
39
800
329
167
115
87
71
63
55
47
43
39
850
349
179
123
95
75
63
59
51
47
43
900
369
187
127
99
79
67
59
55
47
43
950
389
199
135
103
83
71
63
55
51
47
1000
410
207
143
107
87
75
67
59
55
47
1500
612
309
208
159
127
107
95
83
75
67
2000
814
410
277
208
167
143
123
107
95
87
2500
1016
511
346
261
208
176
152
135
119
107
3000
1218
612
410
309
248
208
180
159
143
127
3500
1420
713
479
362
289
245
208
184
164
147
4000
1622
814
548
410
329
277
241
208
187
167
4500
1824
915
612
463
369
309
268
237
208
187
5000
2026
1016
681
511
410
346
297
260
233
208
The above data are based on the parameters in Figure 3, and are the most value size
This calculation parameter table is obtained when the protective cover does not have any accessories. If you have special requirements, please consult our staff in time