Battery power metal pipe flow meter

Model
Nature of the Manufacturer
Other
Product Category
Metal tube float flowmeter
Place of Origin
City, Province
Overview
Battery power metal pipe flow meter
Product Details
Description:

ZW - LZ seriesBattery power metal pipe flow meterCan realize liquid crystal indicator, cumulative, upper and lower alarm output function, such as the type intelligent signal transmitter with and high precision and reliability, can replace imported the same type instrument, and has high cost performance, parameter calibration, power-fail protection, etc.Complex is widely used in various industries, under the bad environment, for small flow and low flow velocity, all kinds of harsh conditions of medium flow measurement and process control.

Second, the structure and working principle:

1, the structure:
Is mainly composed of three parts:
A, indicator (intelligent indicator, on-site indicator);
B, float;
C, tapered measuring room.
2, how it works:
ZW - LZ seriesBattery power tube flow meter bottom-up measured medium by the conical float to the top and bottom side of the differential pressure measurement of a tube formed upward force, when the float upward force is greater than the baptism by float weight in the fluid, float up, clearance area increase, immediately drop the gaps in the fluid flow, float up and down the differential pressure is reduced, acting on the float upward force as well as to reduce, until the upward force equal to the float weight immersed in the fluid, the float is stable at a certain level.The discretion of the float position that corresponds to the size of the measured medium flow.Move up and down in float float the built-in magnet steel, medium, magnetic field changes with the movement of the float.
Type a, for in situ by in situ indicator of the rotating magnet steel and the float inside the magnetic coupling, and turning, drives the pointer at the same time, through the dial indicates the size of the flow at this time.
B, for intelligence, an intelligent indicator in the solid state magnetic sensor to the change of the magnetic field into electrical signals, after A/D conversion, microprocessor, D/A output, LCD liquid crystal display (LCD), to show the size of the flow rate and cumulative flow.
Applications:
ZW - LZ seriesBattery power tube flow meter work reliable, small amount of maintenance and long service life;Widely used in: chemical industry, power generation, food, water treatment, etc.Complex, poor environmental conditions, and conditions in the process of the flow measurement of various media.
Four, the main features:
1, all metal structure design, strong, compact, high pressure, high temperature resistant, corrosion resistant, long service life;
2, short stroke, total 250 mm high, convenient installation;
3, mechanical pointer field indicates the instantaneous flow, LCD liquid crystal display instantaneous flow and cumulative flow;
4, intelligent indicator, adopts the new foreign zui signal collection and processing chip, modular design, without magnetic hysteresis;
5, data recovery, data backup, power-fail protection and fault self-diagnosis function;
6, HART type indicator, two wire 24 VDC power supply, the standard 4-20 ma current signal output stack HART protocol;
7, through the HART communication operator can adjust parameter configuration and on-site;
8, connected to the PC serial port, through the Windows program, the field of instrument calibration;
9, can be used in inflammable and explosive dangerous places;
10, vertical, horizontal, top bottom out, bottom in side out, side in side out, such as a variety of installations, flanged or threaded connections.
Five, the technical parameters:
1, the measuring range: water 2.5 ~ 100000 l/h (20 ℃)
2, range than: 10:1
3, precision grade: 1.0, 1.5, 2.5
4, work stress: DN15, DN25, (for PN4.0 MPazui 10.0 MPa, DN80, greatly DN100 for PN1.6 MPazui was 6.4 MPa
5, medium temperature: - 40 ℃ ~ 300 ℃
6, medium viscosity: DN15: eta < 5 mpa s. (F15.1 ~ F15.3)
Eta < 30 mpa s. (F15.4 ~ F15.8)
DN25: eta < 250 mpa, s
(~ 6: eta < 300 mpa, s
7, environment temperature, liquid crystal type: - 40 ℃ ~ 85 ℃
A pointer type: - 40 ℃ ~ 120 ℃
8, connection: flange (executive standard DIN2501 or made according to standard users with flange)
9, meter height: 250 mm
10, cable interface: M20 * 1.5
11, power supply: 24 VDC two wire 4 ~ 20 ma, or 85 ~ 265 vac 50/60 hz (far eastone type)
12, alarm output: the upper or lower limit instantaneous flow alarm relay output (contact capacity zui big 5 a - 250 vac) or open collector output (100 ma zui large internal impedance Ω 100-30 VDC).
13, pulse output: cumulative pulse output, zui small interval of every 10 seconds a pulse (ac type) or a pulse every 50 milliseconds.
14, liquid crystal display: double row liquid crystal display, display instantaneous flow and cumulative flow.
15, safety explosion-proof: Exia CT4 II.
16, measuring pipe material: stainless steel 316 (ordinary) or lined with ptfe (anti-corrosion type).
Six, the classification of the structure details:
1, high temperature structure type (G)
High temperature structural type (G) is used for medium temperature is too high or too low and need to measure the rate of flow of pipe heat preservation and heat insulation measures of medium measure.High temperature structure is increased the measuring tube and the distance between the indicator to increase heat dissipation, increasing the thickness of insulation material, ensure the indicator work in allow ambient temperature range.Type selection for the "G".Can measure the temperature of 80 ℃ to + 300 ℃ medium flow.
2, the structure of the device with damper (Z)
Damper is structured for flow meter inlet flow (pressure) unstable when the medium flow measurement, especially for the measurement of the gas.
3, the structure of the clamp cover model (T)
Clip model structure used for heating or cooling, such as the high viscosity and crystallization medium flow measurement.In the jacketed by heating or cooling medium, make the low boiling point, fluid evaporation and crystallization.
Import and export of heating medium connection, the standard to use HG20594-97 DN15 PN1.6 flange, other connection flange specification can be indicated with factories, jacketed level of pressure is 1.6 MPa.
4, high pressure type structure (Y)
High pressure type structure used for pressure is greater than the standard level of measured medium flow measurement.High pressure type structure as shown in the figure below.The recent series of FFM64 zui high pressure can reach 32 mpa.Additional high pressure type flowmeter can provide built-in magnetic filter, the installation height is 350 mm.FA, FB and FC zui pressure to 10 mpa.

Seven, product maintenance:
1, in the long-term use process, the pipe will inevitably have a ferromagnetic impurity adsorption on the float, it would float jammed or affect measurement accuracy, need to clean them often float inside the sensor;If the installation of magnetic filter, also want to make regular cleaning.
2, instrument indicator is equipped with electronic components, instrumentation connection or remove the shell and the screw to tighten, must ensure that shell sealing, to prevent impurities, or other material into the water, but also ensure the reliable earthing of the instrument housing.
3, meters installed, in * times when using, should pay attention to:
Open valve to avoid pressure impact spacing device to float against, causes the damage of instrument, must open the valve slowly!
Measuring gas meter is equipped air damper, zui to large extent reduce the oscillation of the float;In order to ensure the stability of float, and can be installed in the export of instrument a throttle valve.
4, for remote transmission type instrument, first of all to ensure the instrument connection right after, can live;For the dangerous situation, must choose explosion-proof type, use and install according to the requirements of explosion-proof.
Eight, troubleshooting methods:
1, check alarm value set size in the SU.
2 d values cannot too big, check the deviation.
The logical function, FUN, whether it is right.HA - A said cap is logical.LA -a said the lower limit is logic
4, circuit board fault, replace the circuit board.
5, if the LCD bar code instructions correct output without action, can check whether the external power supply and external power of the cathode is connected to the instrument power supply of the cathode.
If in use dithering, could be determined according to the extent of jitter is what range of jitter.Jitter is divided into slightly shaking, moderate jitter and violent shaking.
1, the slight shaking: generally caused by fluctuations in medium.Can be used to increase the damping ways to overcome.
2, moderate jitter: generally caused by medium flow state.Is often caused by unstable operating pressure of medium for gas.Can use voltage or current regulator devices to overcome or increase the instrument air damping.
3, intense shaking, mainly due to the medium pulse, pressure instability or users are given gas pressure, temperature and flow of the operating state of inconsistent with the actual state of instrument, have bigger difference meter range.
Nine, installation requirements.
1, checked out after remove the filler of the flow meter, flow meter should be installed vertically on the no vibration of the pipeline, such as horizontal installation, should additional specifications when ordering.The center line of the flowmeter and the vertical Angle should not exceed 5 °.
2, new pipelines in tube flow meter before installing a new pipeline should be rinsed clean, if the medium to be measured particle impurities or bubbles, filters should be installed in the upstream flow meters or set the outlet, fluid when installation must flow from the bottom up, if the fluid flow from the top down, the meter doesn't work.If measured medium is pulsating flow, should be in the downstream set appropriate size buffer device, such as buffer tank to eliminate pulsation.
3, to facilitate the check meter zero and disassembling maintenance and debugging, the cut-off valve should be installed at upstream or downstream flow meter and the by-pass valve.
4, a meter installed by the regulation, should be closed either upstream or downstream flow meter cut-off valve, check instrument and secondary instrument connection again, and, after open secondary instrument power the instantaneous flow shall display to zero.To normal use, should be open upstream first after the valve is fully open, with metal tube flowmeter downstream regulator from small to large, slow flow rate adjustment, the instantaneous flow rate should be changed.Stop working, the upstream downstream of the valve, then close the regulator should be shut down.

Ten, notable matters of installation:
1 meter installation must be before the welding slag, clean up debris within the pipeline.
2 the upright part must be installed perpendicular to the ground slope of the flowmeter shall not exceed 5 °. Otherwise it will affect measurement accuracy.
3 in order to ensure the measuring accuracy of flowmeter, should increase in the inlet side flowmeter in not less than 10 XDN straight pipe, outlet not less than 5 x DN straight pipe, when measuring the regulating valve must be installed on the downstream side of the meter.
If measured medium for big pulsating flow or two phase flow, should be installed upstream of the flow meter buffer to eliminate or weaken the pulsation, ensure the flow of the medium is single-phase stable, at the same time, the Suggestions of the flowmeter using damping type.
5 medium is dirty or containing magnetic particles, advice in magnetic flow meter installed upstream of the filter or filter.
6 meter installation should be able to properly support the pipeline vibration or reduce the axial load meter, it should increase the fixed flow meter.
7 in order to facilitate the maintenance of flowmeter, magnetic filter cleaning and user line of regular maintenance, it is recommended to use as shown follows the bypass pipe.
8 when the flow meter is used for gas, shall ensure that the pipe work pressure not less than five times the flow pressure loss, the flowmeter can stable normal action.
9 for electric remote transmission and take alarm limit switch meter before use, open the cover, according to the wiring diagram wiring correctly.
10 according to the instrument indicator of warning signs, prevent float vibration resistance movement in transport, before using the instrument.

Eleven, flow parameter list:

Menstruation (mm)

Flow range

KPa pressure loss

Water L/h *

Air M3 / h *

water

air

The conventional type

Anti-corrosion type

The conventional type, anti-corrosion type

15

2.5 ~ 25

---

0.07 ~ 0.7

6.5

7.1

4.0 ~ 40

2.5 ~ 25

0.11 ~ 1.1

6.5

7.2

6.3 ~ 63

4.0 ~ 40

0.18 ~ 1.8

6.6

7.3

10 to 100

6.3 ~ 63

0.28 ~ 2.8

6.6

7.5

16 ~ 160

10 to 100

0.40 ~ 4.0

6.8

8.0

25 ~ 250

16 ~ 160

0.7 ~ 7.0

7.2

10.8

40 ~ 400

25 ~ 250

1.0 ~ 10

8.6

10.0

63 ~ 630

40 ~ 400

1.6 ~ 16.0

11.1

14.0

25

100 ~ 1000

63 ~ 630

3 ~ 30

7.0

7.7

160 ~ 1600

100 ~ 1000

4.5 ~ 45

8.0

8.8

250 ~ 2500

160 ~ 1600

7 ~ 70

10.8

12.0

400 ~ 4000

250 ~ 2500

11 ~ 110

15.8

19.0

40

500 ~ 5000

---

12-120

10.8

9.8

600 ~ 6000

----

16 ~ 160

12.6

16.5

50

630 ~ 6300

400 ~ 4000

18 ~ 180

8.1

8.6

1000 ~ 10000

630 ~ 6300

25 ~ 250

11.0

10.4

1600 ~ 16000

1000 ~ 10000

40 ~ 400

17.0

15.5

80

2500 ~ 25000

1600 ~ 16000

60 ~ 600

8.1

12.9

4000 ~ 40000

2500 ~ 25000

80 ~ 800

9.5

18.5

100

6300 ~ 63000

4000 ~ 40000

100 ~ 1000

15.0

19.2

150

20000 ~ 100000

---

600 ~ 3000

19.2

20.3

Twelve, selection of coding:

Code name

Measuring tube structure

ZW-LZ50

In the out

ZW-LZ51

Under the cross out into

ZW-LZ52

The horizontal cross out into

ZW-LZ53R

Right into the left out

ZW-LZ53L

Left to right

ZW-LZ50S

Threaded connections

ZW-LZ50M

Quick connector to connect


Code name

Answer the liquid material

R0

0Cr18Ni2Mo2Ti

R1

1Cr18Ni9Ti

R2

316L

RP

PTFE

T1

titanium alloy


Code name

Pipe size

DN15

15

DN25

25

DN50

50

DN80

80

DN100

100

DN150

150

DN200

200


Code name

Additional structure

There is no


T

Clip model

Z

Damping type

G

High temperature type

Y

High pressure type


Code name

Indicator combination form code

M1

In situ indicator, instantaneous flow machine instructions

M2

Type power supply, mechanical indicates the instantaneous flow rate, liquid crystal display instantaneous/The cumulative flow

M3

Type power supply, no mechanical indicator, liquid crystal display instantaneous/The cumulative flow


code

The power supply mode

There is no

onlyM1indicator

A

220VAC420mAThe output

B

Battery power, no output

C

24VDC, two wire of power supply,420mAThe output

D

24VDC, three, four wire power supply,420mAThe output


Code name

Explosion-proof marks

l

The AnniaCT5Square shell

d

flame-proofDiibt4Garden shell


Code name

Alarm or pulse output

There is no

No alarm or pulse to lose Out of the

K1

Upper limit alarm or pulse output

K2

The lower limit alarm or pulse output

K3

And the lower limit alarm or pulse output

13, design selection and order items:

1, according to the measurement of fluid is a gas or liquid, correct choose ZW - LZ series metal tube flowmeter.

2, be no corrosive choose normal flow corrosive choose corrosion type.

3, when placing order, please indicate the name of the measured medium, flow rate, pipe size and working pressure, temperature, density, viscosity, and so on and so forth.According to density of scale revised by the user, making special flow scale.

4, according to the measuring range of the measurement of body, applications, and choose the right type of specification varieties.If you have any special requirement of the flowmeter, company or calls, please contact the sales department.

After-sales service commitment:

1, from the date of signing of the contract, I in the way provided for products of the company offers free maintenance and maintenance service, commitment to lifelong maintenance service;

2, jiangsu wei measurement and control instrument co., LTD. Sales manager will be in regular contact with customers, understand the usage of products, and solve the problems of the customers to use in the process of produce, free of charge to provide technical support;

3 the man-made damage is found, the warranty period, our company is responsible for the maintenance, and the resulting maintenance fee;

4, product quality problems or are not satisfied with product, the user can choose unconditional return, wei tt&c don't charge any fees, appear quality problem, bear the freight back and forth.