Welcome Customer !

Membership

iangsu Zhongwei Measurement and Control Co., Ltd.
Free Member ·1YRS
Other

Main Products: 流量计

Xwboo>Products
Product Categories

iangsu Zhongwei Measurement and Control Co., Ltd.Free·1YRS

  • E-mail

    zhongweick@163.com

  • Phone

    0517-86918678

  • Address

    No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province

Contact Now

One-piece ultrasonic flowmeter

Model
Nature of the Manufacturer
Other
Product Category
ultrasonic flowmeter
Place of Origin
City, Province
Overview
One-piece ultrasonic flowmeter
Product Details
Description:

Products overview:
ZWS - 100 y seriesOne-piece ultrasonic flowmeterIs the introduction of advanced flow measurement technology and low cost of then send encapsulated into an organic whole, can be directly installed on the measuring point.This product has solved the connection type and insertion type sensor measured pipe during installation due to human or parameter error caused by inaccurate and cause of the decline of the accuracy of measurement.Flow with no moving parts, without daily maintenance, instrument on the microprocessor provides * digital signal encoding and cross-correlation detection procedures, can provide long-term drift measurement.But for almost all clean uniform liquid flow body.
Second, the working principle:
ZWS - 100 y series one-piece type of basic principle of ultrasonic flowmeter and ultrasonic wave travels in the flow of fluid in fluid velocity on load information.So by the received ultrasound can detect the fluid velocity, thus converted to flow.According to the test, can be divided into velocity difference method, doppler method, beam deflection method, noise and the relevant laws such as different types of ultrasonic flowmeter.Sound waves flowmeter is more than ten years along with the rapid development of integrated circuit technology began to be used one.
Applications:
ZWS - 100 y series one-piece ultrasonic flowmeter can measure the fluid is water, sea water, or oil, uniform liquid slurry, conduct electricity or not, corrosive or no corrosive liquid can be measured.
Four, the main features:
1, a variety of power supply mode: single section 3.6 V lithium battery can work for 6 years, the two wire system 4-20 ma, RS232 and RS485 output type, without the battery also can work normally;
2, measuring rich content: circulating cumulative flow, heat accumulation, instantaneous flow, transient heat, for the return water temperature, current, temperature difference, fault running time, work status, date, time, etc.;
3, high protection grade: can achieve IP68 protection grade, can be immersed to 2 meters work;
4, firm structure, measuring section with precision casting process, no leakage, no pressure loss and the moving parts, ten years of free maintenance design;
5, humanized design: magnetic bar operation, internal double button, easy to operate;Fault diagnosis;
6 and ordinary metal pipes such as: carbon steel, stainless steel, cast iron, copper, aluminum, etc.;
7, other nonmetallic pipes, such as: PVC, PR, FRP, such as cement pipe.
Five, the technical parameters:
1, the measurement precision, better than 1%;
2, after sex: better than 0.2%;
3, measurement cycle: 500 ms (2 times per second);
4, work power: 24 VDC or 220 vac (optional);
5, power consumption: 50 ma work power;
6, velocity range: 0 to 32 m/s (velocity resolution of 0.001 m/s);
7, show: local 2 x 10 type backlit display can display Chinese characters: positive and negative cumulant, the instantaneous flow rate, flow velocity, the total work, date, between real work state error code, ultrasonic signal strength and quality, etc.;
8, operations: 16 key touch keyboard;
9, signal input: 3 road 4-20 ma analog input optional precision (0.1%)
2 way three-wire system PT100 resistance signal input is optional;
10, signal output: isolated RS485 output optional (expanding MODBUS protocol, FUJI agreement and compatible with the domestic similar products of other manufacturers communication protocol), 2 road isolation editable OCT output optional (one pulse width between 6 ms - 1 seconds can be set to factory default 200 milliseconds), the extensible 1 ~ 3 road 4-20 ma output optional (passive);
11, connection mode: flange/articulated type (health) optional;
12, other features: can be transmitted to the code file to realize software upgrade;
Records to the first 64 days, 32 months before, the first two years accumulative flow rate and working state, can record 16 times more than before, electricity and traffic, and can automatically or manually flow adding.Programmable controller built-in quantitative, can use the external input signal or start NODBUS instructions;
13, power-off protection: power data is not lost 100000 hours;
14, medium temperature: - 40 ℃ ~ 160 ℃;
15, protection level: IP65;
16, electrical interface: M20 x 1.5.
Six, signal intensity:
Refers to the received signal strength after amplification of ultrasonic signal amplitude, with 3 digits said: [000] is not detected any signal;[999] zui refers to the received signal.
Although the signal between 500-999 meter can work, but the stronger signal strength can get good results, so users should adjust the signal of the sensor to receive to z.
Suggestions according to the following methods of operation to get larger signal strength:
1, if measured flow numerical instability, when signal strength is below 700, to choose a better location measurement.
2, the outer surface of the polishing pipe carefully, some slightly more coupling agent.
3, slightly adjust the relative position of the sensor at the same time observe the flow meter of received signal strength, parked in the signal zui big place, at the same time also want to check if the distance between the sensor can satisfy the demands of M25 window display.
Signal quality (signal good degrees) :
Flowmeter signal quality is to use Q value.Q value means the higher signal-to-noise ratio (SNR) of an acronym, of course, is more accurate, the measured data of the Q values should be between 600-900 range, the higher the better.
Seven, directions for use:
1, zero flow rate checks
Around when the pipeline fluid static, without strong magnetic field interference, strong vibration, header shows zero, automatically set zero point at this time, eliminate the zero drift, the runtime must to remove small signal, usually 5% flow is less than the full process flow, automatic removal.Zero at the same time also can adjust menu.
2, instrument panel keyboard operation
Before start the meter running, the first to set parameters effectively, for example, using the system, installation, pipe diameter, pipe wall thickness, pipe material, pipe roughness, fluid type and the distance between two probes, velocity of flow unit, small speed, speed, etc.All parameters input correctly, instrument can display correctly the actual flow value
3, flowmeter calibration
Guarantee the accuracy of flowmeter, we conduct regular check, usually we use higher precision direct comparison, portable flowmeter: using the test data to compute error = - standard/standard measurements, using relative error calculation, correction factor, satisfy error of measurement error of plus or minus 2%, can meet the measurement requirements.This simple and convenient operation, can effectively improve the accuracy of measuring.

Eight, how to correctly install:
Pipe sections of ultrasonic flowmeter installation distance zui what is appropriate, and how to determine the ultrasonic flowmeter probe position and will affect their use in the future, detailed as follows:
1, the pipeline parameter input instrument, choose pipe installation, installation distance are obtained.
2, V installation: make sure of a point, according to the installation distance in a horizontal position measure another point.
3, ultrasonic flowmeter in horizontal pipe runs, generally should choose the central pipe, avoid the top and bottom.

Nine, fixed tube sections of sensor technology parameters:

Technical parameters

Health type pipe sections

PI.Type of pipe sections of

Standard pipe sections of

Apply to the host

One-piece, split type, economical, flow module

One-piece, fission, economical, flow module, water meter

Suitable diameter

DN25-DN80

DN15-DN40

DN50-DN1000

The material

Stainless steel

Carbon steel (stainless steel) of choose and buy

Working frequency

1MHz

The connection method

Articulated connection

Flange connection

Suitable temperature

-40℃ ~160℃

calibration

The machine online calibration

Protection grade

IP68(diving, water depth3 or lessM.)

Overall dimensions

See the table below

Nominal pressure

See the table below

Medium variety

Water, sea water, sewage, alcohol, such as various oil can conduction ultrasonic single, uniform and stable liquid.

Medium turbidity

≤20000ppmAnd the bubble content is small

Pipe lining material

There is no

Signal cable

SEYV75-2Special type of shielded cable, single can be extended to300Meters, wiring cable should be with metal casing to increase anti-jamming, and pay attention to the cable don't parallel with high voltage cable, as far as possible to avoid the frequency converter and other interference sources.

Ten, selection of code:

model

function

options

ZWS-

100

Instructions (in the wei and control)

A

The host type

Y Pipeline one-piece (local operational set refs)

F1 Fission hanging type F2 Fission hanging explosion-proof typeF3Fission type in tray F4 Fission type local display

M1 Module type (local operational parameter) M2 No operation module type (local,09At the end of production)

S Economy (local operational set refs)

W Water meter (batteries,Magnetic buttons browser window)

B1.

Working power supply

A Communication (85-264VAC)B Cell (3.6VLithium battery) D Dc (24V/8-36VDC)

C

The heat function

N There is no Y There are

D2.

The sensor type

B1 standardS1type B2 standardM1type B3 standardL1type B4 The high temperatureS1Htype B5 The high temperatureM1Htype

C1 Standard plug-in C2 Cement plug in C3 Water meter plug-in

G1 Standard pipe sections (flange) G2 Health pipe sections (articulated connection)

E

Measure the diameter

DN(mm)

F3.

Piping material

0 Carbon steel 1 Stainless steel 2 Cast iron 3 Glass fiber reinforced plastic 4 PVC 5 cement

G

Nominal pressure

MPa

Selection of interpretation:
(1) : ac power is suitable for ZWS - 100 - f type, ZWS - 100 y type, other host models applicable to battery power supply or dc power supply.
Dc power supply is suitable for all types products, in addition to ZWS - 100 f1, F2, F3, ZWS - 100 - s power supply is 24 VDC, the rest 8-36 VDC.
ZWS - 100 - w battery power meter can also be 8 to 36 v power supply, if necessary please specify when ordering.
(2) : the battery power ultrasonic industrial water meter/heat meter, if choose plug-in or external clip-on sensors, measurable pipe diameter for DN800 zui.
(3) : cast iron, glass fiber reinforced plastic, PVC, such as cement welding pipe if choose insert type sensor, need to match special pipe hoop before installation, please specify when ordering.
(4) : z is only applicable to small readings ZWS - 100 - w type battery power ultrasonic water meter selection.
(5) : 4-20 ma output, if choose active work ac or dc 24 v power supply requirements.
OCT 200 ms, pulse width of the factory default Settings programmable between 6 ~ 1000 ms.
Battery power ultrasonic water meter or heat meter RS485 output has two kinds of optional, is a kind of internal lithium battery power supply, the working voltage of 3.3 V, another is to provide dc power to the external, please specify when you place an order, otherwise May 485 output interface is invalid.

Eleven, design selection and ordering information:

1, products: specify model standard, if any, please live in wei sales hotline advisory prices, details!

2, technical support, if not specified product specifications, please put the working condition of requirements, design drawings, technical specifications, to us.

3, product orders for parameters: size (DN), nominal pressure (Mpa), temperature (℃), the connection way (flange, etc.) to the clamp.

4, offer confirmation: the company provide price list and technical standard specifications to customers to confirm, in the technical aspects to confirm before you draw up a contract.

5, quality requirements, quality standards, the supplier is responsible for the quality conditions: according to the relevant state quality standards.

After-sales service commitment:

1, from the date of signing of the contract, I in the way provided for products of the company offers free maintenance and maintenance service, commitment to lifelong maintenance service;

2, jiangsu wei measurement and control instrument co., LTD. Sales manager will be in regular contact with customers, understand the usage of products, and solve the problems of the customers to use in the process of produce, free of charge to provide technical support;

3 the man-made damage is found, the warranty period, our company is responsible for the maintenance, and the resulting maintenance fee;

4, product quality problems or are not satisfied with product, the user can choose unconditional return, wei tt&c don't charge any fees, appear quality problem, bear the freight back and forth.



Similar Product Recommend