Welcome Customer !

Membership

iangsu Zhongwei Measurement and Control Co., Ltd.
Free Member ·1YRS
Other

Main Products: 流量计

Xwboo>Products
Product Categories

iangsu Zhongwei Measurement and Control Co., Ltd.Free·1YRS

  • E-mail

    zhongweick@163.com

  • Phone

    0517-86918678

  • Address

    No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province

Contact Now

Cable type liquid level transmitter

Model
Nature of the Manufacturer
Other
Product Category
Liquid level transmitter
Place of Origin
City, Province
Overview
Cable type liquid level transmitter
Product Details
Description:

Products overview:

ZW - DB501 seriesPart of sensor can be directly into the liquid, transmitter part available flange or bracket, convenient in installation.Used in high temperature and high pressure, strong corrosion, easy to crystallization, under bad conditions, such as easy jam for the detection of various liquids.Suitable for measuring water, acid and alkali solution, and the boiler water level, the whole machine there or elastic parts, impact resistance, easy installation, high reliability, high precision and good cost performance.

Second, the working principle:

ZW - DB501 series cable measured with static pressure type fluid shift delivering principle;When the liquid level transmitter into the liquid to be tested in a certain depth, the sensor to meet the pressure on liquid surface formula is: Ρ = rho. We + Po type:

P: the pressure on the transmitter into liquid level

Rho: the measured liquid density

G: the local acceleration of gravity

Po: atmospheric pressure on the surface of liquid

H: transmitter into the depth of the liquid

At the same time, through the gas leading stainless steel will be introduced to the liquid pressure sensor of positive pressure cavity, and atmospheric pressure on the surface of the liquid Po and sensors connected to the negative pressure cavity, to offset the Po on the reverse of the sensor, the sensor measured pressure is: rho. We, obviously, through the acquisition of pressure P, can get the depth of the liquid level.

Applications:

ZW - DB501 series cable type liquid level transmitter is the extension and development of technology of pressure transmitter.According to the different proportion of liquid in a linear relationship with different produced by high pressure principle, the implementation of the volume of water, oil and paste zhuang, accurate measurement and transmission of liquid height, weight.Widely used in electric power, petroleum, chemical industry, metallurgy, water conservancy, water, food and other industries

Four, the main features:

1, solid structure, no moving parts, high reliability, long service life.

2, from the water to the sewage from oil to viscosity larger liquid can be high precision measurement, not affected by blister, deposition of medium;

3, with multi-purpose mounting bracket, installation is convenient to use;

4, good anti-jamming, lightning-proof ability;

5, has the power supply reverse polarity protection and overload current limiting protection;

6, the new material is not easy to fatigue wear, vibration and impact resistance, strong overload capacity.

7, simple structure, easy to maintenance.

Five, the technical parameters:

1, the measuring range: stainless steel extension rod type 0 ~ 5 m;Guide gas cable type 0 ~ 100 m;

2, the system precision level: 0.2 magnitude 0.5 on the Richter scale;

3, using the environment humidity: - 20 ℃ ~ + 70 ℃;

4, relative humidity: 10% ~ 90%;

5, medium temperature: - 20 ℃ ~ + 80 ℃;

6, long term stability: better than 0.1% FS/year;

7, temperature stability: + 0.2% / 10 ℃;

8, power supply: : 24 VDC;

9, the signal output: two line 4 ~ 20 ma output.

Sixth, other parameters:

1, medium density range: 0.5 g/cm3 ~ 2.0 g/cm3.

2, overload ability: as 5 times as the standard range.

3, transmitter protection grade: IP65.

4, sensors, protection grade: IP68.

5, explosion-proof marks: iaIICT4 intrinsically safe;

6, transmitter shell material: membrane die-casting aluminum;

7, sensor material: type: stainless steel;Anti-corrosion type: ptfe;

8, fitting size: flange (PN2.5 (JB81-59);Thread M56 x 2.

Seven, installation and debugging methods:

1, cable type and lever type liquid level transmitter has many installation fixed way, so as to adapt to different site conditions.When the site will not be able to provide M20 x 1.5 in the process facilities such as thread or the flange, can choose wall installation type, horizontal pipe frame and vertical posture, such as three optional installation way, make you comfortable when installation.

2, when measuring liquidity larger medium, to prevent violent oscillation sensor, the user can choose counterweight attachment, to have the effect of stable sensors, add weight must to put weight objects in the bottom of the container, in order to avoid pull bad sensing wires.

In the field environment is bad, the user should choose sensor shield to protect sensor, to avoid the foreign body damage or affect the accuracy of measurement.

3, when using the lever type liquid level transmitter, if not metal containers, you need to put the transmitter of the shell with a wire access the bottom of the container, otherwise not accurate measurement.

This product in the factory has a calibration, if need on-site adjustment can adopt the following methods:

1, using intelligent circuit debugging methods:

The zero -- -- -- -- -- - when the liquid level position is low, at the same time hold down the "Z" key and "S" key 8 seconds after release at the same time, then "Z" key press, the output current automatically adjusts to 4 ma.

Field adjustable full -- -- -- -- -- - when the liquid level high, at the same time hold down the "Z" key and "S" key 8 seconds after release at the same time, then the "S" key press, automatic adjustment to 20 ma output current.

2, USES the method of analog circuit debugging:

When the liquid level in the next period, use the screwdriver slowly rotating "Z" potentiometer, observe the ammeter reading close to 4 ma.

When the liquid level in the limited time, use a screwdriver slow rotation "S" potentiometer, observe 20 ma current meter reading is close.

So above 2 to 3 times repeatedly, until zero and range are accurate 20 ma ma and 4, respectively.

After adjust, should tighten the lid of the transmitter.

Eight, appearance and installation method:

Appearance:

Cable type liquid level transmitter consists of shell, amplifier, terminal blocks, helmets, hollow wire, etc, according to the needs of the user can choose a pointer table, LCD display meter.

Installation method:

1, choose easy to place for installation operation and maintenance;

2, shall be installed as far as possible away from the vibration source;

3, should be far away from heat source as far as possible;

4 when inputting type liquid level transmitter installation, cable, metal probe to sink to the bottom of the container.

Nine, note:

1, the supply of products with product certificate and instruction manual with the product serial number, technical parameters, wiring diagram, production date, etc. Please check carefully to avoid using wrong.

2, when installation should be according to the product connection and screw type, check the site interface is consistent with the product interface.For screw thread interface, should slow tightened, pay attention to the sealing, can't add the torque directly to the transmitter shell, can only add on the six-party transducer interface.

3, connection should be in strict accordance with the company I use for connection.

4, this product is a precision in instrument, banned free disassembly, collision, drop, play hard.

5, the transmitter power can work, but warm up 30 minutes output stability.

6, if discovery is unusual, in use should turn off the power and stop using, check, or directly to our technical department.

7 should be restored the original packaging, transportation, storage, stored in a cool, dry and ventilated warehouse.

8, installation and use process should pay attention to not put the induction of the skin of the wire broken.

9, when installation induction leads to at least more than 10 cm away from the pool wall, otherwise not accurate measurement.

10, all four fluorine structure and lever type level ground wire must be measured medium conduction, and measurements are not accurate.

11, installation site should take effective lightning protection measures.

12, the series of any liquid level transmitter enclosure must be reliable grounding, grounding resistance should be less than 4 Ω.

13, according to the security gate flame-proof certification, its installation should be according to the requirements of the specification.

14, when the transmitter is used to "0" zone, grid power supply to the safety of the power transformer shall meet the requirements of article 8.1 GB3836.4-2000.

Ten, selection of details:

1, indicate the measuring range (level of), for some special medium, indicate the density of the medium.

2, type selection, attention should be paid to contact with the product of the measured medium material compatibility, for special medium, can be customized.

More than 3, the product installation in the thunderstorm area, the order should be marked "lightning", recommend that users install against lightning protection device at the scene, and make sure products and power grounding.

4, about the selection of gas leading cable length: general than the actual level of 1 ~ 2 meters long.

Eleven, selection of coding:

spectrum

instructions

ZW-DB50

In the liquid level transmitter (wei measurement and control)

category

1

The cabling

2

Lever (sensor installed at the bottom, direct contact with the liquid medium)

3

The anti-corrosion type

4

Guide pressure lever (sensors mounted on the upper, not direct contact with the medium)

Process connection form

T

Bracket installation

N

Flange installationDN40 PN1.0

Y

Specifically agreed

Sensor connection material

1

304

lever

2

316

3

316L

4

Nitrile butadiene rubber and PVC compounds

The cabling

5

Ptfe, flange (pp)

Explosion-proof way

O

Don't riot

E

Safety explosion-proofExia ⅡCT6

Display mode

O

Without the instructions

Z

With current meter instructions (0-99%Scale)

X

A live show

A counterweight

O

Without the weight

W

Need to weight

-□

The installation height (mm)

-□

Measure the height (mm)

-□

Density (measured mediumg/cm3)

Twelve, design selection and ordering information:

1, model specifications: ZW - DB500 series;

2, the name of the measured medium, medium density;

3, instrument measuring range: can also be referred to as the nominal length;

4, work pressure, work under pressure;

5, working temperature: measuring the temperature of the liquid;

6, material requirements: liquid material;

7, whether matching supply flange, bolts, nuts, valves, fittings, such as sealing washer;

8, flange standard: nominal size of the flange, 3/4 ", DN25, (, DN80, DN100, etc;

9, special requirements: before ordering, please indicate in detail.

After-sales service commitment:

1, our company sold by liquid level transmitter series products within twelve months appear quality problem, is responsible for free maintenance.

2, the warranty period, any quality problems such as the products of our company, my company is responsible for free repair or replacement.

3, the warranty period, such as user improper use, damaged products, my company is responsible for the maintenance, charge damage parts cost.

4, after the warranty period appear quality problem, my company is responsible for the maintenance, charge damage parts cost.

5, such as user need to my company site services, to users in the province I company service personnel to reach the site within 12 hours, fujian association of foreign languages and user reach the site within 48 hours.

Similar Product Recommend