Welcome Customer !

Membership

iangsu Zhongwei Measurement and Control Co., Ltd.
Free Member ·1YRS
Other

Main Products: 流量计

Xwboo>Products
Product Categories

iangsu Zhongwei Measurement and Control Co., Ltd.Free·1YRS

  • E-mail

    zhongweick@163.com

  • Phone

    0517-86918678

  • Address

    No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province

Contact Now

Corrosion proof glass tube rotameter

Model
Nature of the Manufacturer
Other
Product Category
Rotor flowmeter
Place of Origin
City, Province
Overview
Corrosion proof glass tube rotameter
Product Details
Description:

Productoverview:

ZW-LZB/ (F Series) Corrosion proof glass tube rotameter Mainly used in chemical, petroleum, light industry, medicine, chemical fertilizer, chemical, food, dyestuff, environmental protection and scientific research departments, used to measure single-phase non pulsating (liquid or gas) fluid flow. Corrosion proof glass rotameter is mainly used for the detection of corrosive liquid and gas medium flow, such as acid (except hydrofluoric acid), alkali, oxidant, strong oxidizing acid, organic solvents and other corrosive gas or liquid medium flow detection.

Two, work principle:

ZW-LZB/ (F) series of anti-corrosion glass tube rotameter, the main measurement components for a vertical installation of small large tapered glass tube, and the float can move up and down. When the fluid from top to bottom through a conical glass tube, the float between the upper and lower pressure difference, the rise in pressure under the action of the float. Buoyancy and viscous lift and float when the rising force, float by gravity is equal, the float is in balance position. Therefore, the fluid flow and float through the glass rotameter height is between the glass rotameter flow meters there is a certain ratio, the float position height can be used as a measure of flow.

Three, main features:

1, small pressure loss. In the process of using, can be fully utilized, without a lot of effort too much, all the pressure can be fully used, there will be no loss.

2, reliable performance. Glass rotor flowmeter in operation, frequent failure will not ensure good operation. When people are in the process of using, don't worry about running for it. Good performance, high reliability, can be assured use.

3, simple structure, convenient installation and use. The structure of the glass rotameter is simple, the installation is very convenient, can be installed in a short period of time.

4, cheap. Buy glass rotameter is cheap, has a great price advantage.

Four, technical parameters:

1, size: DN2 ~ 100mm;

2, measuring range: water (20 C): 1L/h ~ 100m3/h, gas (101325Pa, 20 C): 16L/h ~ 3000m3/h;

3, the range ratio: 10: 1;

4, precision grade: grade 1.5, grade 2.5, grade 4;

5, nominal pressure: DN4 ~ 10 1.0MPa, 50 0.6MPa, DN15 ~ DN80 ~ 100 0.4MPa;

6, working temperature: less than or equal to 120 DEG c;

7, connection: hose, metal pipe, flange (GB/T9119-2000);

8, material: flange, float, a guide rod, a supporting plate and bolts are made of stainless steel 304 (1Cr18Ni9Ti), type LZB-B.

Wetted materials for the 316, is the model for the LZB-Bo, can be customized.

For stainless steel PTFE is type LZB-BF (or BoF), can be customized.

Five, installation instructions:

How to choose the right flowmeter is instantaneous flow measurement instrument using a simple and convenient reading, a very wide range of uses. In the field of environmental protection equipment in the amount of up to instrument 30000 Taiwan / year. Therefore, choose and use this instrument is very important.

1, variety and selection

According to the rotor flowmeter its use and scope can be divided into: ordinary type, ribbed vascular type, small flow and low profile type, corrosion type, laboratory type, insulation type, alarm type and high pressure type eight series.According to the formulation of national instrument series, regardless of which series, ranging from 1 to 100 mm 12 mm diameter, can measure the flow range: liquid (water) 0.1 ml / min ~ 40 / cubic meters, gas (air) 1 ml / min / m3 ~ 1000.For environmental protection equipment of the glass rotameter is generally not more than 10 mm diameter, the flow measurement of small flow range.

2, correction

The scale of the rotor flow meter, is a production plant with a nearly ideal fluid in the factory under the condition of water and dry air as the medium for the calibration. But in the meter the use of the site, a case can not directly use its scale: one is not measuring medium of water and air, the second is measured and the medium is water and air, but the condition (temperature. Pressure) is different from the scale of state. So, in the use of flow time, to get the correct measurement results, there need to revise the scale value problem. Therefore, to solve the glass rotameter scale correction, is the key to good use of this instrument.

Considering the environmental protection equipment used by mining gas rotameter medium flow in great quantities, so just below the gas medium when measuring the density correction is discussed. Because the gas medium viscosity is very small, so the effects of omitting discussion viscosity. Practice has proved that this does not affect the accuracy of the revised.

Six, selection guide:

1, measurement. Measuring the media type, size, pressure and chemical properties. Such as liquid and gas medium, the corrosive medium should choose corrosion resistant glass rotor flowmeter.

2, the performance of flowmeter. The above conditions are identified in general, if the price is no big change, may be preferred needle valve is arranged on the upper part of the large circulation flow meter; hole, direct flow scale; simple structure; small exterior dimensions etc.. Such as small flow range, you can choose to use the ball float type, because of its measurement stability, not easy dust, high precision, good interchangeability.

The price of 3, according to the. Generally speaking, the high price of high precision. According to the measurement instruments such as precision grade, only through the medium of control measure, the operation adjustment, after always stabilize the throughput, so the accuracy is minor.

4, the fluid flows through the cone bottom-up tube, buoyancy A fluid kinetic energy generated on the float lift S and fluid to float up, when the lift and buoyancy of A and S is equal to the gravity float G, float in the balance, stable at a certain height position, scale cone tube on the fluid flow indicator value.

Seven, appearance and installation dimensions:

Table 1,

Path

The size (mm)

A

B

C

D

E

Two

One hundred and ten

One hundred and thirty-two

One hundred and fifty

M8 * 1

31 x 26 (front)

Three

One hundred and ten

One hundred and thirty-two

One hundred and fifty

M8 * 1

31 x 26 (front)

Four

One hundred and seventy

Two hundred and eight

Two hundred and thirty-eight

Phi 11

40 x 34 (front)

Six

One hundred and seventy

Two hundred and eight

Two hundred and thirty-eight

Phi 11

40 x 34 (front)

Ten

One hundred and seventy

Two hundred and eight

Two hundred and thirty-eight

Phi 11

40 x 34 (front)

Table 2:

Diameter (mm)

The size (mm)

A

B

C

D

E

Fifteen

Phi 95

Phi 65

Four hundred and seventy

Phi 15

With the diameter of 14 4-

Twenty-five

Phi 105

Phi 78

Four hundred and seventy

Phi 25

With the diameter of 14 4-

Forty

Phi 145

Phi 110

Five hundred and seventy

Phi 40

With the diameter of 18 4-

Fifty

Phi 160

Phi 125

Five hundred and seventy

Phi 50

With the diameter of 18 4-

Eighty

Phi 185

Phi 150

Six hundred and sixty

Phi 80

With the diameter of 18 4-

One hundred

Phi 205

Phi 170

Six hundred and sixty

Phi 100

With the diameter of 18 4-

Eight, specifications and parameters:

Model

LZB-15F

LZB-25F

LZB-40F

LZB-50F

LZB-80F

LZB-100F

Nominal diameter

Phi 15

Phi 25

Phi 40

Phi 50

Phi 80

Phi 100

Ratio measurement

1:10

1:10

1:10

1:10

1:5 1:10

1:5

Working pressure

Less than or equal to 0.6

Less than or equal to 0.6

Less than or equal to 0.6

Less than or equal to 0.4

Less than or equal to 0.4

Less than or equal to 0.4

Precision grade

Four

Two point five

Two point five

Two point five

Two point five

Two point five

Flow range

Liquid (m3/h)

16-160 (L/h)

40-400 (L/h)

0.16-1.6

0.4-4.0

1-10

5-25

25-250 (L/h)

60-600 (L/h)

0.25-2.5

0.6-6.0

1.6-16

8-40

40-400 (L/h)

100-1000 (L/h)





Gas (NM3/h)

0.25-2.5

1-10

4.0-40

10-100

50-250

120-600

0.4-4.0

1.6-16

6.0-66

16-160

80-400

200-1000

0.6-6.0

2.5-25





Nine, the selection of encoding:

ZW-LZB

-

caliber

function

Description (Zhongwei control)



DN2-100


caliber


No label

Ordinary type

F

Corrosion proof type, PTFE base (for DN2~DN10) or carbon steel flange lining PTFE

B

All stainless steel material: 304 stainless steel

B0

All stainless steel material: 316 stainless steel

F/B (B0)

Type: stainless steel corrosion-resistant stainless steel flange (304 or 316) lined with PTFE (for DN15~DN100)




W

Food grade sanitary cl

ZW-LZB

-

.

.

Glass tube flowmeter

Ten, design and ordering:

1, please provide the pipe size, wall thickness, material requirements and accuracy requirements;

2, please provide a liquid or gas, such as the name, commonly used commonly used temperature, working pressure, common flow, density, viscosity etc.;

3, choose anti-corrosion type, should indicate the measured corrosion and concentration etc.;

4, if there are special to show, please with the Sales Department of the company.

Customer service service commitment:

1, our series of flowmeter series product quality problems within 12 months, responsible for free maintenance.

2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.

3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.

4, the warranty period after the product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.

5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.


Similar Product Recommend