Description:
Productoverview:
WSS series Door type double metal thermometer Axial, radial type, universal type header type selection. The thermometer probe rod length can be customized according to customer needs. The scene temperature display, intuitive and convenient safe and reliable, long service life; core pulling type thermometer can not stop short time maintenance or replacement of movement. The axial and radial type, 135 type, universal type, complete varieties, suitable for various on-site installation need.
Two, work principle:
WSS series Door type double metal thermometer Is the principle of expansion work in varying degrees of temperature change when using two different metals. The main components for industrial use is one with two or more metal sheet laminated together to form a multilayer metal sheet. In order to improve the measurement sensitivity, usually made of sheet metals of spiral shape. When the multilayer metal sheet temperature changes, each layer of metal expansion or shrinkage range, so that the spiral rolled up or loosen. Since the end of the spiral coil is fixed and the other end and a pointer can rotate freely. Therefore, when the feeling of double sheet metal to temperature changes, in a pointer to the circular indexing on the gauge indicates the temperature to.
Three, application:
WSS series Door type double metal thermometer It can directly measure the production process in a variety of -80 to +500 DEG C range of liquid, steam and gas temperature. Widely used in petroleum, chemical, machinery, shipbuilding, power, textile, printing and dyeing industry and scientific research departments.
Four, main features:
1, the scene display temperature, convenient, safe and reliable, long life and other characteristics.
2, victims of mercury free, easy reading, strong shock.
3, the protection pipe of 1Gr18Ni9Ti stainless steel and two molybdenum titanium, pressure, strong corrosion resistance.
4, core pulling type thermometer can not stop short time maintenance or replacement of movement.
5, the axial and radial type, 135ordm; type, universal type, complete varieties, suitable for various on-site installation need.
Five, technical parameters:
1, the implementation of standards: JB/T8803-1998 GB3836-83;
2, dial diameter: ;
3, accuracy: (1, 1.5);
4, thermal response time: less than 40S;
5, protection grade: IP65;
6, adjust the angle error: adjustment angle error should not exceed the range of 1%;
7, back to the poor: the return difference should not be greater than the absolute value of the basic error limit;
8, repeatability: repeatability limit should be less than the absolute value of basic error of 1/2.
Six, matters needing attention
1, can not be directly screw head;
2, the length of choice to choose the standard size close to the (integer multiples of 50mm);
3, the protective tube immersionmedium measured in length must be greater than the length of the sensing element, the general recommended immersion length is greater than 100mm, 0-50 DEG C immersion length range is more than 150mm, to ensure the accuracy of measurement.
4, should not be used to measure open container medium temperature.
In 5, storage, installation and transportation, should avoid collision protection tube, do not allow the protection tube bending change, but not the table when using the wrench.
6 regular inspection, under normal conditions of use should be. In general, every six months.
7, not allowed to work in the strong vibration environment, to prevent the influence of double metal life, does not allow the use of electric contact in the control loop vibration occasions, so as not to affect the reliability.
Seven, temperature range:
The measuring range of C | Applicable scope |
Industrial and commercial | Laboratory and small |
-80 ~ +40 | B. | B. |
-40 ~ +80 | B. | B. |
0 ~ 50 | B. | B. |
0 ~ 100 | B. | B. |
0~150 | B. | B. |
0~200 | B. | B. |
0~300 | B. | B. |
0~400 | B. | B. |
0~500 | B. | B. |
Remarks:
One The insertion depth of the thermometer, L Must be greater than Lmin , L Alternative series: One hundred , One hundred and fifty , Two hundred , Two hundred and fifty , Three hundred , Four hundred , Five hundred , Seven hundred and fifty , One thousand , One thousand two hundred and fifty , One thousand and five hundred , Two thousand So, also can be customized according to user needs.
Two And the protective tube diameter Phi 6 , Phi 8 The series of thermometers, the time constant is less than FortySecond, diameter Phi 10 When the time constant is less than Thirty Seconds.
Three Protect the stainless steel tube 1Cr18Ni9Ti Manufacturing, at room temperature under high working pressure is Zui 6.4MPa .
Eight, shape and size:
structural style | A | B | C | E | L | D |
Axial type | Sixty-five | Twenty-three | Seventy-three | - | Seventy-five One hundred One hundred and fifty Two hundred Three hundred Four hundred Five hundred Seven hundred and fifty One thousand | Phi 6 Phi 8 Phi 10 |
One hundred and five | Twenty-three | Seventy-three | - |
One hundred and fifty-five | Twenty-three | Seventy-three | - |
Radial type | Sixty-five | Fifty | One hundred and ten | Thirty-four |
One hundred and five | Fifty | One hundred and ten | Thirty-four |
One hundred and five | Fifty | One hundred and ten | Thirty-four |
135 degrees to type | One hundred and five | Twenty-three | Eighty-five | - |
One hundred and fifty-five | Twenty-three | Eighty-five | - |
Universal type | One hundred and five | Twenty-three | One hundred and seventy-eight | One hundred and twenty |
One hundred and fifty-five | Twenty-three | One hundred and seventy-eight | One hundred and twenty |
Nine, the specific model name that said:
One Axial type
Model | Measuring range | Precision grade | Protection tube material | Specifications | Fixed form |
D | L |
WSS-300 | -80 ~ +40 -40 ~ +80 0~50 0~100 0~150 0~200 0~300 | One point five | 1Cr18Ni9Ti Three hundred and four Three hundred and sixteen 316L Hastelloy C-276 | Phi 60 | Seventy-five One hundred One hundred and fifty Two hundred Three hundred Four hundred Five hundred Seven hundred and fifty One thousand | No fixed device |
WSS-400 | Phi 100 |
WSS-500 | Phi 150 |
WSS-301 | Phi 60 | Movable external thread |
WSS-401 | Phi 100 |
WSS-501 | Phi 150 |
WSS-302 | Phi 60 | The movable internal thread |
WSS-402 | Phi 100 |
WSS-502 | Phi 150 |
WSS-303 | Phi 60 | Fixed thread |
WSS-403 | Phi 100 |
WSS-503 | Phi 150 |
WSS-304 | Phi 60 | Fixed flange |
WSS-404 | Phi 100 |
WSS-504 | Phi 150 |
WSS-305 | Phi 60 | Card set screw |
WSS-405 | Phi 100 |
WSS-505 | Phi 150 |
WSS-306 | Phi 60 |
WSS-406 | Phi 100 | Sleeve flange |
WSS-506 | Phi 150 |
Two Radial type
Model | Measuring range | Precision grade | Protection tube material | Specifications | Fixed form |
D | L |
WSS-310 | -80 ~ +40 -40 ~ +80 0~50 0~100 From 0 to 150 0~200 0~300 0~400 0 ~ 500 | One point five | 1Cr18Ni9Ti Three hundred and four Three hundred and sixteen 316L Hastelloy C-276 | Phi 60 | Seventy-five One hundred One hundred and fifty Two hundred Three hundred Four hundred Five hundred Seven hundred and fifty One thousand | No fixed device |
WSS-410 | Phi 100 |
WSS-510 | Phi 150 |
WSS-311 | Phi 60 | Movable external thread |
WSS-411 | Phi 100 |
WSS-511 | Phi 150 |
WSS-312 | Phi 60 | The movable internal thread |
WSS-412 | Phi 100 |
WSS-512 | Phi 150 |
WSS-313 | Phi 60 | Fixed thread |
WSS-413 | Phi 100 |
WSS-513 | Phi 150 |
WSS-314 | Phi 60 | Fixed flange |
WSS-414 | Phi 100 |
WSS-514 | Phi 150 |
WSS-315 | Phi 60 | Card set screw |
WSS-415 | Phi 100 |
WSS-515 | Phi 150 |
WSS-316 | Phi 60 |
WSS-416 | Phi 100 | Sleeve flange |
WSS-516 | Phi 150 |
Three , 135 degrees To type
Model | Measuring range | Precision grade | Protection tube material | Specifications | Fixed form |
D | L |
WSS-420 | -80 ~ +40 -40 ~ +80 0 ~ 50 0 ~ 100 0 ~ 150 0 ~ 200 0~300 0~400 0~500 | One point five | 1Cr18Ni9Ti Three hundred and four Three hundred and sixteen 316L Hastelloy C-276 | Phi 100 | Seventy-five One hundred One hundred and fifty Two hundred Three hundred Four hundred Five hundred Seven hundred and fifty One thousand | No fixed device |
WSS-520 | Phi 150 |
WSS-421 | Phi 100 | Movable external thread |
WSS-521 | Phi 150 |
WSS-422 | Phi 100 | The movable internal thread |
WSS-522 | Phi 150 |
WSS-423 | Phi 100 | Fixed thread |
WSS-523 | Phi 150 |
WSS-424 | Phi 100 | Fixed flange |
WSS-524 | Phi 150 |
WSS-425 | Phi 100 | Card set screw |
WSS-525 | Phi 150 |
WSS-426 | Phi 100 | Sleeve flange |
WSS-526 | Phi 150 |
Four Universal type
Model | Measuring range | Precision grade | Protection tube material | Specifications | Fixed form |
D | L |
WSS-480 | -80 ~ +40 -40 ~ +80 0 ~ 50 0 ~ 100 0 ~ 150 0 ~ 200 0 ~ 300 0~400 0~500 | One point five | 1Cr18Ni9Ti Three hundred and four Three hundred and sixteen 316L Hastelloy C-276 | Phi 100 | Seventy-five One hundred One hundred and fifty Two hundred Three hundred Four hundred Five hundred Seven hundred and fifty One thousand | No fixed device |
WSS-580 | Phi 150 |
WSS-481 | Phi 100 | Movable external thread |
WSS-581 | Phi 150 |
WSS-482 | Phi 100 | The movable internal thread |
WSS-582 | Phi 150 |
WSS-483 | Phi 100 | Fixed thread |
WSS-583 | Phi 150 |
WSS-484 | Phi 100 | Fixed flange |
WSS-584 | Phi 150 |
WSS-485 | Phi 100 | Card set screw |
WSS-585 | Phi 150 |
WSS-486 | Phi 100 | Sleeve flange |
WSS-586 | Phi 150 |
Ten, the selection of encoding:
Serial number | WSS |
| (Zhongwei control) |
Dial diameter | -3 |
| Phi 60 |
-4 |
| Phi 100 |
-5 |
| Phi 150 |
Dial form | Zero |
| The axial (straight) |
One |
| Radial (angle) |
Two |
| 135 degrees to (an obtuse type) |
Eight |
| Universal (angle adjustable type) |
Fixed form | Zero |
| No fixed device |
One |
| Movable external thread |
Two |
| The movable internal thread |
Three |
| Fixed thread |
Four |
| Fixed flange |
Five |
| Card set screw |
Six |
| Sleeve flange |
Type of protection | - |
| Ordinary type |
W |
| Type of protection |
F |
| Anti-corrosion type |
The selection of examples:
Universal type, dial diameter 100, the temperature range of 0~400 DEG C, level 1.5, rotatablemale thread M27 * 2 450mm, length WSS-481, 0~400 C, L=450, M27 * 2, 1.5.
Eleven, design and ordering:
Please provide the type, dial diameter, precision grade, fixed form, the range of temperature measurement, protection material, pipe length or depth of insertion.
Customer service service commitment:
1, my company sold Zhongwei Thermometer series The product within twelve months of quality problems, responsible for free maintenance.
2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.