Description:
Products overview:
ZW - XMBA seriesFour is ZW - XMDA road signal input display mode.Drag it is its own research and development, integrated circuit manufacturers custom application-specific integrated circuit production, it not only collected all kinds of monitoring instrument in the automatic control system for most of the functionality, and integrates the CPU, I/D interface RS485 and RS232 communication interface, EPROM and D/A conversion circuit, supplemented by eclecticism, elaborate, repeated debug system, using the instrument has the following features:
1. ZW - XMBA series intelligent four loop display apparatus hardware are greatly reduced, the system structure is relatively simple, the technology is improved significantly, did not fly line, no potentiometer, all the parameters setting, instrument calibration function are all turn a completed by keyboard.
2. ZW - XMBA series intelligent four loop display apparatus can be set four five alarm output, alarm method can reach more than a dozen.Four relay can be arbitrarily allocated to all the way to four road input measurement control;Four road input can achieve unity upper and lower alarm;Can be set to one of the switch to the other three switch monitor have a choice, and to realize intelligent acousto-optic alarm with sound attenuation time.
3. ZW - XMBA series intelligent four loop display apparatus optional add 1 or 2 way or 3 way D/A, the analog output can achieve instant analog output instrument, instrument minimum analog output, instrument maximum average output, instrument simulation output.Also can be set arbitrary number 1 as a starting point for three consecutive road analog output.
4. ZW - XMBA series intelligent four loop display apparatus linear signal input can be defined per the zero value and full of all the way and the decimal digits, also can add prescribing shows small signal removal function.
Second, the technical parameters:
1. The accuracy of measurement: plus or minus 0.5% FS + 1 word
2. Adjust the control accuracy: a type: plus or minus 0.5% FS
3. The simulation precision analog output: plus or minus 0.5% FS, plus or minus 0.2% FS
4. The analog input impedance:
Current signal: 50 or less Ω;A voltage signal: 500 k or Ω;
Thermal resistance exterior resistance: 10 or more Ω;Thermocouple signal: 100 k Ω or higher
5. Analog output impedance:
Current signal: 0 ~ 10 ma acuity 1.5 K Ω;4 ~ 20 ma Ω 150 or higher
Voltage signal: 0 ~ 5 v, 1 ~ 5 v output impedance Ω 1 or less
6. Warning: upper limit and lower limit, lower limit and upper limit and lower limit on poor, poor last time, next time, double difference, OK way and the way of absolute value.7. The relay contacts capacity: AC22V 3 a resistance (load)
After 8. Relay setting parameters remain time: 20 years or more
9. Power supply: AC220V, 50 hz, 6 w or 24 v or less
10. The work environment requirements: temperature: 0 ~ 50 ℃, relative humidity: 85% or less non-corrosive, no vibration.
Three, shows that:
1. 4 screen: PV1 screen first all the way the measured value of the input signal
P2v screen first all the way the measured value of the input signal
PV3 screen first all the way the measured value of the input signal
PV4 screen first all the way the measured value of the input signal
Note: if the instrument is 16 road inspection:
1 ~ 4 road measured values at the same time, according to the indicator H, D, F is not on
Measured value at the same time, according to 5 ~ 8 road lamp lights F, H and D the light not bright
Measured values at the same time, according to 9 ~ 12 road lamp lights D, H, F the light not bright
Measured value at the same time, according to 13 ~ 16 road lamp D, the F lights, H light not on
2. Single + four beams: single: display screen can be arbitrary display of the measured value of the input signal all the way, bring about key to switch.
Column 1: display all input in the form of percentage of measured signals;
Pillar 2: in the form of percentage according to the first two input signal measured;
Column 3: in the form of percentage according to the third road input signal measured;
Column 4: in the form of percentage according to the fourth road input signal measured;
Note: if the instrument is 16 road inspection: when the display shows the measured value of the 1 ~ 16 input signals;
1 ~ 4 percentage of measurement value of four beams at the same time, according to the indicator G, H is not on;
Percentage of measurement value of 5 ~ 8 road four beams at the same time, according to H lamp lights, G the light not bright;
Percentage of measurement value of 5 ~ 12 road four beams at the same time, according to the indicating lamp G lights, H the light not bright;
Percentage of measurement value of 13 ~ 16 road four beams at the same time, according to the indicating lamp G, H the light;
3. The indicator light
A lamp or J1 lamp: for SP1 point lights.
E light or J2 light: for SP2 point lights.
B the light or J3: for SP3 point lights.
C light or J4 light: for SP4 point lights.
Lamp of G, H lamp, lamp of D, the F lamp used to indicate a digital channel.
Four, selection table:
ZW-XMBA | —— | instructions |
Design sequence | 8 | In the intelligent four loop display apparatus (wei measurement and control) |
Display mode | 1 | Four screen |
2 | Single + four beams |
Input mode (the same) | 1 | With a thermocouple (E, K, S, B, J, T, R, N) |
2 | With thermal resistance (Pt100, Cu50, Cu100, BA1, BA2, G) |
3 | With a dc voltage (0 ~ 10 ma, 4 ~ 20 ma) |
4 |
|
5 | With remote transmission pressure resistance and linear resistance value (0 ~ 400 Ω) |
Control the output and the adjustment way | 1 | Measurements show only four road, no control |
2 | Four-way unified set upper limit and lower limit alarm value (public 2 relay only) |
3 | Four-way independent setting upper limit and lower limit alarm value (public 2 relay only) |
4 | Four independent setting the upper or lower limit alarm value (each with 1 alone relay only) |
5 | The first of the first two independent setting upper limit and lower limit alarm value (each alone with 2 relay only) |
6 | The first three way alarm output all the way, the first 2 one way alarm output |
7 | The first four way alarm output all the way |
8 | SP3 for monitoring other stations, and have a sound and light alarm function |
Overall dimensions | H | Horizontal type 160 x 80 | Opening 152 x 76 |
V | Vertical 80 x 160 | Opening 76 x 152 |
Analog output | A | A | A | There is no analog output |
B | B | B | Analog 0 ~ 10 ma |
C | C | C | Analog output 4 ~ 20 ma |
D | D | D | Analog 0 ~ 5 v |
E | E | E | Analog output 1 ~ 5 v |
F | F | F |
|
Timing function | S | Default is no timing function |
With the function of timing |
For the 24 v dc power supply | P | Default is no 24 v dc power supply output |
| With 24 v dc output power (to do two wire transducer power) |
Communication interface | T | The default is not to bring a communication interface |
With RS485 and RS232 communication interface |
Power supply |
| The default is 220 vac |
K | Switching power supply of 85 ~ 260 vac |
W | Switching power supply 18 to 36 VDC or 18 ~ 36 vac |
After-sales service commitment:
1, our company sold by wei measurement and control products quality problems within twelve months, responsible for free maintenance.
2, the warranty period, any quality problems such as the products of our company, my company is responsible for free repair or replacement.
3, the warranty period, such as user improper use, damaged products, my company is responsible for the maintenance, charge damage parts cost.
4, after the warranty period appear quality problem, my company is responsible for the maintenance, charge damage parts cost.
5, such as user need to my company site services, to users in the province I company service personnel to reach the site within 12 hours, fujian association of foreign languages and user reach the site within 48 hours.