High temperature and high pressure thermocouple
Description:
Productoverview:
WRNG-430 series High temperature and high pressure thermocouple The measurement and control of temperature of high temperature and high pressure place suitable for petroleum and chemical industries in the production process.Temperature is an indispensable device for oil refineries, high-pressure polyethylene etc..
Two, Working principle:
WRNG-430 series High temperature and high pressure thermocouple Is the welding of two different material a conductor or semiconductor A and B together to form a closed loop. When two points of attachment conductor A and B 1 and 2 between the temperature difference between the two, will produce electromotive force, thus forming a size of the current in the circuit, this phenomenon is called the thermoelectric effect. Thermocouples use this to work.
3, Thermocouple type:
WRNG-430 series High temperature and high pressure thermocouple Can be divided into standard thermocouple and non standard thermocouple two categories. The so-called standard thermocouple refers to the national standard, the relationship between the thermal potential temperature and allowable error, and indexing table standard thermocouple, which shows its supporting instrument available. Non standard thermocouple in the range of use or magnitude are not standardized thermocouple, in general there is no unified indexing table, mainly used for measuring some special occasions. Standard thermocouple according to IEC international standard production, and designated S, R, B, K, N, E, J, T eight standard thermocouple thermocouple for unified design.
Four, performance characteristics:
1, high precision measurement. Thanks to direct contact with the object, is not affected by the intermediate medium.
2, wide measuring range. The commonly used thermocouple from -50~+1100 C can be continuous measurement, some special thermocouple Zui low detectable -269 C (such as gold iron nickel chromium).
3, simple structure, convenient use. A thermocouple is usually composed of two different metal wires, and the limitation of size and opening, with protective sleeve, it is very easy to use.
Five, Technical parameters:
1: M20x1.5, NPT1/2, electrical outlet;
2: M20x1.5, NPT1/2, connecting dimensions;
3, protection grade: IP65;
4, every burst: D "BT4, D, CT5;
5, nominal pressure: 15-40MPa.
Six, Structural requirements:
Two, high temperature and high pressure thermocouple thermoelectric 1 pole welding must be strong;
Good insulation should be between 2, a power pole each other in case of short circuit;
3, the free end of the thermocouple compensation wire and connected to the convenient and reliable;
4, to protect the casing should be able to guarantee the thermode fully isolated from harmful medium.
Seven, The protection and selection of pipe material:
Texture of material | The use of temperature | Characteristic and Application |
1Cr18Ni9Ti | -200 - 800 | High temperature corrosion resistance, usually the general use of heat resistant steel |
Three hundred and four | -200 - 800 | Low carbon content, with good resistance to intergranular corrosion, usually as a general use of heat resistant steel |
Three hundred and sixteen | -200 - 750 | Low carbon content, has good resistance to intergranular heat-resistant steel used as usual |
316L | -200 - 750 | Ultra low carbon content, with good resistance to intergranular corrosion, usually used as heat resistant steel |
310S | -200 - 1000 | High temperature oxidation resistance, corrosion resistance, heat-resistant steel used as usual |
GH3030 | 0 - 1100 | Nickel based high temperature alloy steel has excellent oxidation resistance, corrosion resistance, heat-resistant steel used as usual |
8, Casing type selection:
The flange can choose 900 (PN15) - 2500LB (PN40) RJ in different forms.
Code | N | M | D | D | D1 | D2 |
A | M20x1.5 (NPT1/2) | NPT1 " | Phi 34 | Phi 9 | Phi 23 | Phi 18 |
B | NPT11/4 " | Phi 45 | Phi 9 | Phi 28 | Phi 23 |
Nine, Flange standard code:
Standard code | Document number |
China national standard | GB9112-9131-88 |
China Ministry of chemical industry standard | HG20592-20635-97(HGJ44-76-91)(HG5001-5028-58) |
China standard of machinery | JB/T74-90-94(JB81-82-59) |
American Standard | ASME/ANSI B16.5-88 |
German standard | DIN 2628-2638-1975 |
Japan standard | JIS2201-1796 |
Ten, Type and specification table:
Model | Graduation | The measuring range of C | Thermal response time | Protection tube material | Specification Lxl |
WRNG-430WRN2G-430 | K | 0-800 | < 180S | 1Cr18Ni9Ti | 380x150430x200480x250530x300580x350630x400680x450 |
WREG-430WRE2G-430 | E | 0-600 |
WRNG-440WRN2G-440 | K | 0-800 |
WREG-440WRE2G-440 | E | 0-600 |
Note: 1, Thermocouple I according to the ordering protocol;
2, the protection tube materials according to ordering protocol
3, the model 430 is waterproof type, type 440 for flameproof type.
Eleven, Design selection and ordering information:
1, model;
2, division no.;
3, precision grade;
4, protection tube material and form;
5, the flange specifications and forms;
6, the length or depth of insertion.
Customer service service commitment:
1, my company sold Zhongwei Thermocouple series The product within twelve months of quality problems, responsible for free maintenance.
2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.