Welcome Customer !

Membership

iangsu Zhongwei Measurement and Control Co., Ltd.
Free Member ·1YRS
Other

Main Products: 流量计

Xwboo>Products
Product Categories

iangsu Zhongwei Measurement and Control Co., Ltd.Free·1YRS

  • E-mail

    zhongweick@163.com

  • Phone

    0517-86918678

  • Address

    No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province

Contact Now

High temperature and high pressure thermocouple

Model
Nature of the Manufacturer
Other
Product Category
Thermocouple
Place of Origin
City, Province
Overview
High temperature and high pressure thermocouple
Product Details
Description:

Productoverview:
WRNG-430 series High temperature and high pressure thermocouple The measurement and control of temperature of high temperature and high pressure place suitable for petroleum and chemical industries in the production process.Temperature is an indispensable device for oil refineries, high-pressure polyethylene etc..
Two, Working principle:
WRNG-430 series High temperature and high pressure thermocouple Is the welding of two different material a conductor or semiconductor A and B together to form a closed loop. When two points of attachment conductor A and B 1 and 2 between the temperature difference between the two, will produce electromotive force, thus forming a size of the current in the circuit, this phenomenon is called the thermoelectric effect. Thermocouples use this to work.
3, Thermocouple type:
WRNG-430 series High temperature and high pressure thermocouple Can be divided into standard thermocouple and non standard thermocouple two categories. The so-called standard thermocouple refers to the national standard, the relationship between the thermal potential temperature and allowable error, and indexing table standard thermocouple, which shows its supporting instrument available. Non standard thermocouple in the range of use or magnitude are not standardized thermocouple, in general there is no unified indexing table, mainly used for measuring some special occasions. Standard thermocouple according to IEC international standard production, and designated S, R, B, K, N, E, J, T eight standard thermocouple thermocouple for unified design.

Four, performance characteristics:

1, high precision measurement. Thanks to direct contact with the object, is not affected by the intermediate medium.

2, wide measuring range. The commonly used thermocouple from -50~+1100 C can be continuous measurement, some special thermocouple Zui low detectable -269 C (such as gold iron nickel chromium).

3, simple structure, convenient use. A thermocouple is usually composed of two different metal wires, and the limitation of size and opening, with protective sleeve, it is very easy to use.

Five, Technical parameters:
1: M20x1.5, NPT1/2, electrical outlet;
2: M20x1.5, NPT1/2, connecting dimensions;
3, protection grade: IP65;
4, every burst: D "BT4, D, CT5;
5, nominal pressure: 15-40MPa.
Six, Structural requirements:
Two, high temperature and high pressure thermocouple thermoelectric 1 pole welding must be strong;
Good insulation should be between 2, a power pole each other in case of short circuit;
3, the free end of the thermocouple compensation wire and connected to the convenient and reliable;
4, to protect the casing should be able to guarantee the thermode fully isolated from harmful medium.
Seven, The protection and selection of pipe material:

Texture of materialThe use of temperatureCharacteristic and Application
1Cr18Ni9Ti-200 - 800High temperature corrosion resistance, usually the general use of heat resistant steel
Three hundred and four-200 - 800Low carbon content, with good resistance to intergranular corrosion, usually as a general use of heat resistant steel
Three hundred and sixteen-200 - 750Low carbon content, has good resistance to intergranular heat-resistant steel used as usual
316L-200 - 750Ultra low carbon content, with good resistance to intergranular corrosion, usually used as heat resistant steel
310S-200 - 1000High temperature oxidation resistance, corrosion resistance, heat-resistant steel used as usual
GH30300 - 1100Nickel based high temperature alloy steel has excellent oxidation resistance, corrosion resistance, heat-resistant steel used as usual

8, Casing type selection:
The flange can choose 900 (PN15) - 2500LB (PN40) RJ in different forms.

CodeNMDDD1D2
AM20x1.5 (NPT1/2)NPT1 "Phi 34Phi 9Phi 23Phi 18
BNPT11/4 "Phi 45Phi 9Phi 28Phi 23

Nine, Flange standard code:

Standard codeDocument number
China national standardGB9112-9131-88
China Ministry of chemical industry standardHG20592-20635-97(HGJ44-76-91)(HG5001-5028-58)
China standard of machineryJB/T74-90-94(JB81-82-59)
American StandardASME/ANSI B16.5-88
German standardDIN 2628-2638-1975
Japan standardJIS2201-1796

Ten, Type and specification table:

ModelGraduationThe measuring range of CThermal response timeProtection tube materialSpecification Lxl
WRNG-430WRN2G-430K0-800< 180S1Cr18Ni9Ti380x150430x200480x250530x300580x350630x400680x450
WREG-430WRE2G-430E0-600
WRNG-440WRN2G-440K0-800
WREG-440WRE2G-440E0-600

Note: 1, Thermocouple I according to the ordering protocol;
2, the protection tube materials according to ordering protocol
3, the model 430 is waterproof type, type 440 for flameproof type.
Eleven, Design selection and ordering information:
1, model;
2, division no.;
3, precision grade;
4, protection tube material and form;
5, the flange specifications and forms;
6, the length or depth of insertion.
Customer service service commitment:
1, my company sold Zhongwei Thermocouple series The product within twelve months of quality problems, responsible for free maintenance.
2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.


Similar Product Recommend