Description:
Productoverview:
WRN series Thermal sleeve type thermocouple The heat protection casing and thermocouple separation combination, the use of the user can be nested in thermal protection tube welding equipment or pipeline, and then loaded thermocouple can be used, has the advantages of improving the protection of pipe work pressure and service life, and convenient maintenance and replacement in the thermocouple, the factory production of heat set the protective tube and deep blind hole processing technology, the protection of the end of the pipe without welding, thereby improving heat protection tube strength and service life.
Two, work principle:
WRN series Thermal sleeve type thermocouple Two different components of the conductor (called thermocouple wire or thermal electrode) is connected to the two ends of the synthetic circuit, when the junction temperature at the same time, in the loop will produce electromotive force, this phenomenon is called the thermoelectric effect, and this is called thermal electromotive force emf. A thermocouple is used to measure temperature of this principle, which is directly used for measuring the temperature of a medium called the working end (also known as the measuring end), the other end is called the cold end (also known as the end of the cold end compensation); and display instrument or meter display instrument connection, will point out that the thermoelectric potential generated by thermocouple.
Three, application:
WRN series Thermal sleeve type thermocouple Suitable for steam pipe, boiler and other on temperature, pressure and flow requirements of the place.
Fourth, the main features:
1, simple assembly, convenient replacement;
2, a spring type temperature sensing element, good anti vibration performance;
3, a large range of temperature;
4, high mechanical strength, good pressure resistance.
Five, technical parameters:
1, electrical outlet: M20x1.5, NPT1/2;
2, size: M20x1.5, NPT1/2 connection;
3, protection grade: IP65.
Six, thermal sleeve type protective sleeve installation steps are as follows:
1, in the pipeline of the measured medium hole. In order to protect the triangle cone casing firmly installed on the pipe wall, the through holes can drill a diameter of 38mm, and then expanded to 42mm in diameter, 38mm diameter hole reaming will keep 10mm long.
2, the installation of welding casing. Install the casing length, should ensure the protection of the triangle cone sleeve firmly against the hole diameter of 38mm.
3, inserted into the protective sleeve. When the triangular cone protective sleeve with 38mm hole seal, protect casing and casing should be installed between the welding gap enough.
4, the protective sleeve is welded on the installation sleeve.
7, so that ordinary thermal sleeve type thermocouple:
1, the product structure
Two Parameter
name call | type Number | Graduation | Measuring range | Nominal pressure | flow speed | Protection tube material |
Single thermocouple | WRNR-01 | K | 0~600 C | Less than 29.4MPa | Less than 100m/s | 1Cr18Ni9Ti |
WRER-01 | E |
Twin thermocouple | WRNR2-01 | K |
WRER2-01 | E |
Eight, The flue duct, the thermocouple:
1, use commonly used in temperature measurement and flue duct.
2, the product structure
Three Parameter
name call | type Number | Graduation | Measuring range | Nominal pressure | Protection tube material |
Single thermocouple | WRNR-12 | K | 0~800 C | Less than 9.8MPa | 1Cr18Ni9Ti |
WRER-12 | E |
Twin thermocouple | WRNR2-12 | K |
WRER2-12 | E |
A single heat resistance | WZP-12 | Pt100 | -200~500C |
Double heat resistance | WZP2-12 |
Nine, high temperature and high pressure that:
1, use: is suitable for high temperature and high pressure or high pressure.
2, the product structure
Three Parameter
name call | type Number | Graduation | Measuring range | flow speed | Protection tube material |
Single thermocouple | WRNR-13 | K | 0~800 C | Less than 100m/s | 0Cr18Ni12M02Ti |
WRER-13 | E |
Twin thermocouple | WRNR2-13 | K |
WRER2-13 | E |
A single heat resistance | WZP-13 | Pt100 | -200~500 C |
Double heat resistance | WZP2-13 |
The length of product placement L (mm) :
Ten, medium temperature and medium pressure:
1, the product structure
Two Parameter
name call | type Number | Graduation | Measuring range | Nominal pressure | flow speed | Protection tube material |
Single thermocouple | WRNR-14 | K | 0~800 C | Less than 29.4MPa | Less than 100m/s | 1Cr18Ni9Ti |
WRER-14 | E |
Twin thermocouple | WRNR2-14 | K |
WRER2-14 | E |
A single heat resistance | WZP-14 | Pt100 | -200~500C |
Double heat resistance | WZP2-14 |
immersion on length L (mm) : 50100150200250300
11, the low temperature and low pressure:
1, the product structure
Two Parameter
name call | type Number | Graduation | Measuring range | Nominal pressure | flow speed | Protection tube material |
Single thermocouple | WRNR-15 | K | 0~800 C | Less than 2MPa | Less than 9m/s | The protective tube ( III ) M33*2 |
WRER-15 | E |
Twin thermocouple | WRNR2-15 | K |
WRER2-15 | E |
Single thermocouple | WRNR-15A | K | The protective tube ( IV ) ZG1 " ( NPT1 " ) |
WRER-15A | E |
Twin thermocouple | WRNR2-15A | K |
WRER2-15A | E |
A single heat resistance | WZP-15 | Pt100 | -200~500C | M33*2 |
Double heat resistance | WZP2-15 |
A single heat resistance | WZP-15A | ZG1 " ( NPT1 " ) |
Double heat resistance | WZP2-15A |
Protection tube material: 1Cr18Ni9Ti
immersion on length L (mm) : 50100150200250300
Twelve, flange connection description:
1, the product structure
Two Parameter
name call | type Number | Graduation | Measuring range | Nominal pressure | flow speed | Protection tube material |
Single thermocouple | WRN-4318 | K | 0~800 C | 4MPa | Less than 80m/s | 1Cr18Ni9Ti |
WRE-4318 | E | 0~600 C |
Twin thermocouple | WRN2-4318 | K | 0~800 C |
WRE2-4318 | E | 0~600 C |
A single heat resistance | WZP-4318 | Pt100 | -200~500C |
Double heat resistance | WZP2-4318 |
immersion on length L (mm) : 50100150200250300
Thirteen, the conical pipe flange connection:
1, the product structure
Two , parameter
name call | type Number | Graduation | Measuring range | Nominal pressure | flow speed | Protection tube material |
Single thermocouple | WRN-43C | K | 0~800 C | 4MPa | Less than 80m/s | 1Cr18Ni9Ti |
WRE-43C | E | 0~600 C |
Twin thermocouple | WRN2-43C | K | 0~800 C |
WRE2-43C | E | 0~600 C |
A single heat resistance | WZP-43C | Pt100 | -200~500C |
Double heat resistance | WZP2-43C |
immersion on length L (mm) : 50100150200250
Fourteen, selection list:
W | R | Specifications | Content (Zhongwei control) |
|
| R |
| 30- platinum rhodium 6 |
P |
| 10- platinum rhodium |
N |
| Nickel chromium nickel silicon |
E |
| Nickel - chromium (chromium Constantan) |
Thermocouple material | - | One |
| No fixed device |
Two |
| Fixed screw type |
Three |
| Movable flange |
Four |
| Fixed flange |
Five |
| A movable flange square form |
Six |
| Fixed thread taper protection tube |
Fixed form | Two |
| Splash proof |
Three |
| Waterproof type |
Four |
| Flameproof type |
Connection box | Zero | 16mm protection tube |
One | 25mm protection tube (double casing) |
Two | 16mm high aluminum tube (single tube) |
Three | 20mm high aluminum tube |
DesIgn Serial Number | . |
W | R | . | - | . | . | . | . |
Example: thermocouple, type K, class I, fixed thread M27 * 2, protective tube 316L, length 450mm, the insertion depth of 300mm. WRN-220, K I, L * l=450 * 300, grade I, protective tube 316L, thread M27 * 2.
Note: 1, grade I, grade a thermocouple thermal resistance according to the ordering protocol;
2, the protective tube is made of 1Cr18Ni9Ti material, the order according to the agreement;
3, 12 types of connection thread is M60X3, 12A connection thread is NPT2". The protective tube is made of 1Cr18Ni9Ti.
Eight, design selection and ordering information:
Please provide the indexing number, precision grade, fixed form, protection material, length or depth of insertion tube (protective tube length L=l+150, special insertion depth and protection tube material can be ordered according to the agreement).
Customer service service commitment:
1, my company sold Zhongwei thermocouple series product quality problems within twelve months, responsible for free maintenance.
2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.