Welcome Customer !

Membership

iangsu Zhongwei Measurement and Control Co., Ltd.
Free Member ·1YRS
Other

Main Products: 流量计

Xwboo>Products
Product Categories

iangsu Zhongwei Measurement and Control Co., Ltd.Free·1YRS

  • E-mail

    zhongweick@163.com

  • Phone

    0517-86918678

  • Address

    No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province

Contact Now

High Temperature Compensation Wire

Model
Nature of the Manufacturer
Other
Product Category
Cable tray series
Place of Origin
City, Province
Overview
High Temperature Compensation Wire
Product Details
Description:

A brief introduction, conductor:
Temperature compensation wireThe effect is to extend the thermode that cold end of thermocouple temperature measurement system and display instrument is connected.High temperature thermocouple compensation wire insulation layer and protective layer according to the environmental requirements of the selected material is not the same, PVC sheath material, fluorine plastic, low smoke and low halogen PVC and alkali free glass wire several imported high-quality fluorocarbon can be high temperature of 260 DEG C, and the continuous extrusion process, make the product has excellent acid resistance, alkali resistance, and flame extension performance, can be used for a long time in oil.
Temperature compensation wireThe use of temperature in - 60 - 260 C, which belongs to the contemporary domestic advanced level.Series of products are mainly used in various types of temperature measuring device, according to the variety of products is divided into SC, KC, KX, EX, JX, TX, NC.
Two, the implementation of standards: GB/T4989/94 equivalent to IEC584.3,
Three, use range:
Temperature compensation wireApplicable to energy, metallurgy, petroleum, chemical and other industrial enterprises and scientific research departments, the temperature control system.For the connection between the cold end temperature measuring instrument and temperature measuring instrument.Heat type imported fluorine plastic insulated and sheathed with excellent heat resistance, waterproof, anti-corrosion, anti acid, chemical resistance, resistance to abrasion, aging and combustion performance.Use temperature of -60 to 260 DEG C, is the international advanced level.
Three, the conditions of use:
(1): highest working temperature: heat with 200 degrees and 260 degrees two;
General: a maximum of 70 degrees and 105 degrees two.
(2) the lowest ambient temperature: fluorine plastic insulated and sheathed cable laying: -60 C -20 C non fixed installation;
PVC insulated and sheathed cable laying: -40 C -15 C non fixed installation.
(3) the minimum bending radius: PVC insulated and sheathed cable non armored cable is not less than 6 times of cable diameter, 10 times of fluoroplastic insulation and sheath for non armored cable is not less than the diameter of the cable, not less than 12 times of cable diameter for armored cable.
Four,Temperature compensation wireThe use of characteristics:

type

The minimum bending radius

The lowest temperature

Maximum temperature

Unarmored

Armoured

Fixed installation

Non fixed installation

General type
There are 105 types of ""
There are 90 types of ""
High temperature type

6 times of the cable diameter
10 times of the cable diameter

12 times of the cable diameter

C = -40

C = -60
 

C = -15

C = -20
 

Less than or equal to 70 DEG C
Less than or equal to 105 DEG C
Less than or equal to 90 DEG C
Less than or equal to 250 DEG C

Five, product code and meaning:

project

Code

Code meaning

project

Code

Code meaning

Model

SC

Thermocouple compensation wire, S index

Heat resistant grade

Seventy

The highest temperature is 70 DEG C

RC

Thermocouple compensation wire, R index

One hundred and five

The highest temperature is 105 DEG C

NC

Thermocouple compensation wire, N index

Two hundred

The highest temperature is 200 DEG C

NX

Thermocouple compensation wire, N index

Two hundred and fifty

The highest temperature is 250 DEG C

KCA
KCB

Thermocouple compensation wire, K index

Insulating materials

V

polyvinyl chloride

KX

Thermocouple compensation wire, K index

Y

polyethylene

EX

Thermocouple compensation wire, E index

B

polypropylene

JX

Thermocouple compensation wire, J index

F4

Teflon

T

Thermocouple compensation wire, T index

F46

Poly perchloro ethylene propylene

Series code

ZR

Flame retardant cable

Jacket material

V

polyvinyl chloride

IA

Intrinsically safe cable

B

glass fibre

The use of classification

G

For general use

F4

Teflon

H

heat resistant

F46

Poly perchloro ethylene propylene

Precision grade

S

Precision

Shielding material

P

Copper wire braid

P1

Tinned copper braid

/

Common grade

P2

Copper tape wrapped

P3

Aluminum / plastic composite film wrapping

Specifications


2 x conductor cross-sectional area mm2

Conductor type


Single conductor can be omitted

R

Stranded conductors

Armored

Twenty-two

Steel tape

Thirty-two

Steel wire armoured

Six, technical indicators:
1 type alloy wire material and insulation color

Compensation wire type

Thermocouple

Mark thermocouple

Compensation lead wire

The insulation layer of color

Positive order

The negative

Positive order

The negative

SC

10- Platinum Rhodium Platinum thermocouple

S

SPC (copper)

SNC (Cu, Ni)

red

green

RC

13- platinum rhodium thermocouple

R

RPC (copper)

RNC (Cu, Ni)

red

green

KCA

Nickel chromium nickel silicon thermocouple

K

KPCA (iron)

KNCA (Cu, Ni)

red

blue

KCB

KPCB (copper)

KNCB (Cu, Ni)

red

blue

KX

KPX (CR)

KNX (Ni SI)

red

black

NC

Ni Cr Si Ni Si thermocouple

N

NPC (iron)

NNC (Cu, Ni)

red

ash

NX

NPX (Ni Cr SI)

NNX (Ni SI)

red

ash

EX

Nickel - copper nickel thermocouple

E

EPX (CR)

ENX (Cu, Ni)

red

Brown

JX

The iron - copper nickel thermocouple

J

JPX (iron)

JNX (Cu, Ni)

red

purple

TX

Copper - copper nickel thermocouple

T

TPX (copper)

TNX (Cu, Ni)

red

white

2, the use of protective layer of color classification

The use of classification

Precision grade and sign

Jacket color

Common grade

Precision

Common grade

Precision

For general use

G

/

S

black

gray

heat resistant

H

/

S

black

yellow

Seven, delivery requirements:
According to both agreements, the length of measurement error is about 0.5%.
Eight, ordering:
In order to indicate the product name, type, number, temperature rating, shielding type, quantity etc..


Similar Product Recommend