Welcome Customer !

Membership

南京宏沐科技有限公司
Free Member ·1YRS
,
Other

Main Products: 传感器

Xwboo>Products
Product Categories

南京宏沐科技有限公司Free·1YRS

  • E-mail

    hmsensor@163.com

  • Phone

    800-828-9705

  • Address

    Nanjint city jiangning shuangnong street number 568 taixing square 1-1302

Contact Now

HM1151 Capacitor -type Differential Pressure Transducer

Model
Nature of the Manufacturer
Other
Product Category
Differential Pressure
Place of Origin
City, Province
Overview
HM1151 capacitor -type differential pressure transducer adopts advanced technology and equipment that we introduced from the foreign countries, of which key raw material, elements and components are imported and strictly assembling and commissioning has been made for the complete machines. It features advanced design principle, full specifications and variants, and simple installation and operation etc. The intellectual series has been researched and developed lately are a kind of intellectual transducer more suita......
Product Details

Features of Product

Application of Product

Details

☆ High accuracy, good stability
☆ 4- wire system (specially)
☆ Solid elements, tie – in PCB
☆ Compact structure, light weight, solid, and vibration resistant
☆ Externally Continuous adjustment of range and zero point
☆ Positive immigration up to 500% and negative immigration up to 600%
☆ Adjustable damping
☆ Good single – way overloading protection characteristics
☆ Without moveable mechanical components and small maintenance workload
☆ Full series of unified structure and with strong interchangeability of components
☆ Optional material of membrane contacting medium (such corrosion – resistant material as 316L, TAN, HAST – C, MONEL etc)
☆ Designed with explosion – proof structure, may be operated under any weather condition


导线: Lead
电容… Capacitor Pole Board
中心… Central Measuring Membrane
刚性… Rigid Isolator
硅油Silicon Oil
隔离… Isolating Membrane
焊接… Welding Seal

• • • Working Principle• • •

The process pressure is transferred to the central measuring membrane of δ chamber through the isolating membrane on both sides or one side. The central membrane is a tensioned elastic element, which may generate corresponding deformation displacement for the pressure difference on the both side applied on it, of which displacement is direct proportion to the pressure difference. The maximum displacement is approximately 0.1mm. This displacement is converted into a differential capacitance formed on the capacitor pole board and the differential capacitance is converted into 2 – wire 4 ~ 20mA signal output through electronic circuit.


HM1151 Capacitor -type Differential Pressure Transducer

• • • Functional Indicators• • •

Object:

Liquid, gas, or vapor

Range of measurement:

0 ~ 0.125KPa ~ 40MPa

Signal output:

4 ~ 20mA

Power supply of energization

12 ~ 45V DC (24V DC generally)

Load characteristic:

Related to the power supply of energization. The load impedance RL has a relationship to the voltage of the power supply: RL ≤50 (VS – 12) Ω

Indicating gauge:

Pointer type with an indication 0 ~ 99% scale, LCD display (0 ~ 99% linear) and square root indication 0 ~ 10 scale.

Explosion – proof:

a. Explosion – isolating type d II BT4

b. Intrinsically safe type in II CT6

Measuring scale and zero point:

Externally and continuously adjustable

Positive and negative immigration:

The lower and upper limit of the scale shall not exceed the scale limit after positive and negative immigration.

Maximum positive immigration: 500% of the minimum measuring scale

Maximum negative immigration: 600% of the minimum measuring scale

Range of temperature:

The range of operating temperature for the amplifier: -29 ~ +93℃ (: -25 ~ +70℃ for LT type)

The measuring element filled with silicon oil: : -40 ~ +104℃

Flange –type transducer filled with high – temperature silicon oil: : +15 ~ +315℃; that filled with general silicon oil: : -40 ~ +150℃

Static pressure and overloading pressure:

4, 10, 25, 32MPa

Humidity:

Relative humidity (RH) 0 ~ 99%

Volume intake capacity:

< 0.16cm3

Damping (step response):

Continuously adjustable, between 0.2s ~ 1.67s generally when filled with silicon oil.

Starting time:

2s, preheating is unnecessary.

Accuracy:

± 0.25% FS; ± 0.5% FS

Dead zone:

None (≤ 0.1%)

Stability:

Not exceeding the absolute value of the basic tolerance for the maximum scale within six months.

Influence of temperature:

Under the maximum scale: zero position tolerance is ± 0.1% / 55℃, the total tolerance is ± 0.15% / 55℃.

Under the minimum scale: zero position tolerance is ± 0.1% / 55℃, the total tolerance is ± 0.2% / 55℃.

Influence of vibration:

On the any axial direction, the tolerance is ± 0.05% / g of the upper limit of the measuring range when the frequency of vibration is 200Hz.

Influence of power supply:

Less than 0.005% / V of the scale output

Influence of load:

The load has no influence to it if the power supply is stable.

Influence of installing position:

0.24KPa zero point tolerance may be generated, as a maximum, but it may be corrective, without influence to the measuring scale.

Isolating membrane: 316LSST, Hastelloy alloy C, MONEL, or tantalum.

Gas exhaust / liquid discharging valve: 316LSST, Hastelloy alloy C, MONEL

Flange and joint: Electroplated carbon steel, 316LSST, Hastelloy alloy C, or MONEL

O – ring contacting medium: NBR, fluorubber

Oil filled: Silicon oil or inertia oil

Enclosure of electronic parts: Low – copper aluminum alloy

Pressure – leading connecting part:

The connecting screw hole on the pressurized vessel or chamber is 1 / 4 ~ 18NPT, the connecting screw hole on the pressure – leading joint is 1 / 2 ~ 14NPT.

Connecting hole of the signal wire:

G1 / 2

Weight:

Approximately 5.4kg (excluding accessories)

Standard accessories:

The flanged joints, gas exhaust valves and liquid discharging valves and one book of instruction manual have been provided for all the variants in the factory before delivery.

Product selection

Similar Product Recommend