Medical Equipment Filter YB11-C1-C2
Features
--Screw-on mounting from front side.
--(R5) types comply with the requirements of IEC/EN60601-1 for safety clearance, leakage current and hipot testing.
--There are a variety of parts and combinations to meet different customer's EMC tests.
--Customized products according to customer's requirements.
Electrical schematic
Rule of Nomination
| YB | 11 | C2 | - | 10A | - | Q | (R | 5 | G) |
|
| | | | |
| | |
| | | | | | | | | C1: Two Fuses |
| circuit
| shell
| - | current
| - | output
| optional
| optional
| optional
| C2: Two Fuses |
Medical equipment
| Model No. | Rated Current @40°C
| Terminal Options
| Bleeder resistor (optional) | Medical equipment 5 | G | Leakage current 250V/50Hz | Electrical Schematic | Rated Voltage (V) | Operating Frequency (Hz) |
|
| | | |
| YB11C2-1A-x(R5) | 1A | Q | S | - | 1 | 5 | - | <> | Fig.1 |
|
|
| YB11C2-2A-x(R5) | 2A | Q | S | - | 1 | 5 | - | Fig.1 |
| YB11C2-3A-x(R5) | 3A | Q | S | - | 1 | 5 | - | Fig.1 |
| YB11C2-4A-x(R5) | 4A | Q | S | - | 1 | 5 | - | Fig.1 |
| YB11C2-6A-x(R5) | 6A | Q | S | - | 1 | 5 | - | Fig.2 |
| YB11C2-8A-x(R6) | 8A | Q | S | - | 1 | 5 | - | Fig.2 |
| YB11C2-10A-x(R5) | 10A | Q | S | - | 1 | 5 | - | Fig.2 |
Mechanical Dimension
Insertion loss table(In 50ohm system according IEC/CISPR 7)
| -------common mode | -------differential mode |