Air cooled high temperature hot oil pump
Air cooled high temperature oil pump is reasonable in structure, good in performance and reliable in use. The utility model is suitable for conveying high temperature liquid without solid particles. The corrosion resistance and the temperature of the application depend on the material of the main parts in contact with the medium (three categories: 1.HT200; II.ZG230-450; III.1Cr18Ni9Ti, OCr18Ni12-Mo2Ti)
Air cooled high temperature oil pump:
Air cooling type high temperature hot oil pump is suitable for conveying the weak corrosive liquid without solid particles, but also according to the needs of users, the use of different parts of the flow of material, conveying corrosive or other special properties of liquid. Application: temperature is not higher than 350 DEG flow: 1-270 cubic meters / hour
In addition, the air cooled high temperature oil pump is widely used in the machinery industry, food industry, pharmaceutical production, fuel supply system, hot oil heating cycle system. The application of air-cooled heat pump in the industry is more extensive, its main application is the petroleum chemical industry, textile printing and dyeing industry, dyestuff industry, wood processing, plastics and rubber processing industry, food industry, papermaking and printing industries.
Structural characteristics of air cooled high temperature oil pump:
Air cooled high temperature oil pump with soft packing seal, with good thermal adaptability, reliable sealing without leakage. No additional cooling equipment, low operating costs. High performance, high efficiency, small size, low noise, long term stability. Oil pump is axial suction, centrifugal conveying, cantilever supporting structure.
The significance of air cooled high temperature oil pump: taking RY100-65-200A as an example
| RY | 100 | 65 | 200 | A | |
| Hot oil pump | Pump inlet diameter | Pump outlet diameter | Impeller nominal diameter | Indicates that the outer diameter of the impeller cutting a good second (D, E said the variant impeller) | |
Performance parameters of air cooled high temperature oil pump:
| Pump type | flow | lift | speed n | power kw | efficiencyη | Motor (type Y) |
| m3/h | m | r/min | Shaft power | Matched power | % | Base number |
| 15-15-100 | 3 | 10 | 2800 | 0.45 | 0.75 | 20 | 801 |
| 15-15-100A | 2 | 10 | 2800 | 0.36 | 0.55 | 18 | AO2-7122 |
| 15-15-100B | 1 | 10 | 2800 | 0.2 | 0.37 | 15 | AO2-7112 |
| 20-20-100 | 1 | 10 | 2800 | 0.09 | 0.37 | 26 | AO2-7112 |
| 20-20-125 | 1.5 | 22 | 2800 | 0.22 | 0.75 | 30 | 801 |
| 40-25-160 | 10 | 28 | 2900 | 1.72 | 2.2 | 45 | 90L |
| 25-25-160 | 3 | 27 | 2900 | 0.53 | 1.5 | 30 | 90S |
| 32-32-160 | 6 | 28 | 2900 | 0.85 | 1.5 | 50 | 90S |
| 50-32-160 | 12.5 | 30 | 2900 | 1.9 | 3 | 57 | 100L |
| 50-32-200 | 18 | 40 | 2900 | 3.92 | 5.5 | 50 | 132Sl |
| 50-32-200A | 16 | 32 | 2900 | 3.35 | 4 | 42 | 112M |
| 50-32-250 | 12.5 | 80 | 2900 | 6.2 | 11 | 44 | 160Ml |
| 65-50-160 | 20 | 32 | 2900 | 3.17 | 5.5 | 55 | 132S1 |
| 65-40-200 | 30 | 48 | 2900 | 6.3 | 7.5 | 62 | 132S2 |
| 65-40-200A | 25 | 35 | 2900 | 4 | 5.5 | 59 | 132S1 |
| 65-40-250 | 25 | 80 | 2900 | 10.3 | 15 | 53 | 160M2 |
| 65-40-250A | 20 | 51 | 2900 | 5.67 | 7.5 | 49 | 132S2 |
| 65-40-315 | 25 | 125 | 2900 | 18.9 | 30 | 45 | 200L1 |
| 65-40-315A | 22.5 | 100 | 2900 | 15.3 | 22 | 40 | 180M |
| 80-50-200 | 50 | 50 | 2900 | 9.7 | 15 | 70 | 160M2 |
| 80-50-200A | 45 | 40 | 2900 | 7.8 | 11 | 63 | 160M1 |
| 80-50-200B | 40 | 32 | 2900 | 6.37 | 7.5 | 55 | 132S2 |
| 80-50-250 | 50 | 80 | 2900 | 17.1 | 22 | 58 | 180M |
| 80-50-250A | 43 | 60 | 2900 | 12.8 | 15 | 55 | 160M2 |
| 80-50-315 | 50 | 125 | 2900 | 30.4 | 45 | 56 | 225M |
| 80-50-315A | 45 | 100 | 2900 | 23.6 | 30 | 52 | 200L1 |
| 100-65-200 | 100 | 50 | 2900 | 18.4 | 22 | 74 | 180M |
| 100-65-200A | 94 | 44 | 2900 | 16 | 22 | 70 | 180M |
| 100-65-200B | 87 | 38 | 2900 | 13.8 | 15 | 65 | 160M2 |
| 100-65-200C | 80 | 32 | 2900 | 11.8 | 15 | 59 | 160M2 |
| 100-65-250 | 100 | 80 | 2900 | 32.06 | 37 | 68 | 200L2 |
| 100-65-250A | 95 | 72 | 2900 | 29 | 37 | 64 | 200L2 |
| 100-65-250B | 90 | 65 | 2900 | 26.2 | 30 | 61 | 200L1 |
| 100-65-250C | 85 | 50 | 2900 | 20.3 | 30 | 57 | 200L1 |
| 100-65-315 | 100 | 125 | 2900 | 50.06 | 75 | 68 | 280S |
| 100-65-315A | 95 | 113 | 2900 | 45.23 | 55 | 64.63 | 250M |
| 100-65-315B | 90 | 100 | 2900 | 40.5 | 55 | 60.5 | 250M |
| 100-65-315C | 82 | 84 | 2900 | 34.76 | 45 | 54 | 225M |
| 125-100-200 | 200 | 50 | 2900 | 35.4 | 45 | 77 | 225M |
| 125-100-200A | 178 | 40 | 2900 | 26.6 | 37 | 73 | 200L2 |
| 125-100-250 | 200 | 70 | 2900 | 47 | 55 | 80 | 250M |
| 125-100-250A | 190 | 63 | 2900 | 41.6 | 55 | 78 | 250M |
| 125-100-250B | 180 | 57 | 2900 | 37.9 | 45 | 74 | 225M |
| 125-100-250C | 170 | 51 | 2900 | 32.15 | 45 | 72 | 225M |
| 125-100-250D | 150 | 70 | 2900 | 40 | 45 | 70 | 225M |
| 150-150-200 | 350 | 50 | 2900 | 60 | 75 | 80 | 280S |
| 150-150-200A | 313 | 40 | 2900 | 45 | 55 | 76 | 250M |
| 200-150-400 | 350 | 50 | 1450 | 61.8 | 75 | 78 | 280S |
| 200-150-400A | 330 | 45 | 1450 | 52.8 | 75 | 77 | 280S |
| 250-200-400 | 500 | 50 | 1480 | 86.2 | 110 | 79 | 315S |
| 250-200-500 | 500 | 80 | 1480 | 136 | 160 | 76.5 | 315M |
| 250-200-500A | 400 | 50 | 1480 | 75 | 90 | 73 | 280M |