Stainless steel electric four way reversing ball valve
Stainless steel electric four way reversing valve for the X type ball valve vertical channel, it features two channels for the X sphere shaped layout, the four channels are distributed on the circumference of the ball diameter on the section, when the ball along the clockwise 90, two channels can make the adjacent 22 interchange.
Note: parameters are for reference only, or are not full. Valve can be used in accordance with the requirements of different pressure, material, caliber. Specific please contact or online advisory contact.
Accessory name | Material |
| GB | ASTM |
Body,bonnet | WCB | A216-WCB |
Sealing Ring | PTFE、Para polystyrene PTFE、Counterpoint polypheny1 | PTFE、Para polystyrene PTFE、Counterpoint polypheny1 |
Ball | 1Cr18Ni9Ti | SS 304 |
Seat、Stem | 2Cr13 | A246-416 |
Dual-head double-screw bolt | 35CrMoA | A193-B7 |
PN(MPa) Nominal diameter | Test pressure |
| Shell | High-pressure liquid sealing | Low-pressure hermetic sealing |
1.6 | 2.4 | 1.76 | 0.6 |
2.5 | 3.75 | 2.75 | |
4.0 | 6.0 | 4.4 | |
CLASS150 | 3.O | 2.2 | |
Applicable Operating Mode
| Applicable medium | Non-corrosion medium such as water, oil products, and gas, etc,and nitric acid corrosion medium. |
| Applicable temperature | -28-350℃ |
Applicable specification | Connecting flange | JB79-59、GB9113、HG20592-97、ANSI B16.5 |
| Test and inspection | GB9/T 9092-99、API 598 |
Other manufacturing standard is according to the standard of our factory. |
Nominal pressure | Main dimension
| Nominal diameter |
15/1/2″ | 20/3/4″ | 25/1″ | 32/11/4″ | 40/11/2″ | 50/2″ | 65/21/2″ | 80/3″ | 100/4″ | 125/5″ | 150/6″ | 200/8″ |
PN1.6MFb | L | 150 | 150 | 180 | 200 | 220 | 240 | 260 | 280 | 320 | 380 | 440 | 550 |
PN2.5MFh | L1 | 75 | 75 | 90 | 100 | 110 | 120 | 130 | 140 | 160 | 190 | 220 | 275 |
PN4.0MFb | H | 90 | 90 | 102 | 115 | 135 | 140 | 155 | 185 | 210 | 275 | 305 | 335 |
CLASS150 | W | 140 | 140 | 155 | 250 | 250 | 350 | 350 | 420 | 700 | 1000 | 1300 | 1800 |
For the rest of the flange dimensions, please refer to the sample. |