The equipment and piping of the valve is applied to the working temperature are less than 200 E steam boiler and similar medium, as the overpressure protection device. When the equipment and pipeline pressure exceeds the allowable value, the valve automatically opens, then the whole amount of discharge; when the pressure is reduced to the specified value, the valve automatically closed to ensure the safe operation of the equipment.
Note: parameters are for reference only, or are not full. Valve can be used in accordance with the requirements of different pressure, material, diameter, drive, etc.. Specific please contact or online advisory contact.
No Information
Model | Nominal pressure/Mpa | Strength test pressure/Mpa | Setting pressure/Mpa | working temperature/℃ | Applicable medium |
JA22H-2.5 | 0.25 | 0.4 | 0.1 | ≤200 | E boiler and similar non corrosive medium boiler |
JA22W-2.5P | 0.25 | 0.4 | 0.1 | ≤200 | Equipment and piping for corrosive medium |
Nominal diameter DN(mm) | size(mm) | weight(kg) |
| do | ZG | G | S | Φ | Φ2 | L | L1 | H | |
25 | 14 | 1″ | 11/4″ | 41 | 25 | 90 | 50 | 65 | 180 | 3.35 |
32 | 18 | 11/4″ | 11/2″ | 48 | 32 | 105 | 55 | 75 | 205 | 7.3 |
40 | 23 | 11/2″ | 2″ | 56 | 40 | 120 | 60 | 85 | 240 | 9.4 |
50 | 28 | 2″ | 21/2″ | 62 | 50 | 140 | 65 | 95 | 280 | 15 |
65 | 40 | 21/2″ | 3″ | 82 | 60 | 160 | 75 | 110 | 330 | 21 |