Medical sanitary diaphragm valve
The valve diaphragm imported silicone rubber reinforcing body, through high-speed polishing, finish to Ra0.2um, absolutely sterile, non hole angle, system is widely used in biology, pharmaceutical, electronics and other aseptic demanding.
Note: parameters are for reference only, or are not full. Valve can be used in accordance with the requirements of different pressure, material, diameter, drive, etc.. Specific please contact or online advisory contact.
Body: SUS316L non ferrous alloy
Diaphragm: silicone rubber
Lining layer: electric spark detection
Test and inspection according to GB/T 13927 standard
Nominal pressure: PN (MPa)
Body: PN * 1.5
Seal: PN * 1.1
Nominal diameter DN | Nominal pressure MPa | A mm | B mm | E mm | F mm |
15 | 1.0 | 108 | 34 | 80 | 89/99 |
20 | | 118 | 50.5 | 80 | 91/102 |
25 | | 127 | 50.5 | 80 | 110/123 |
32 | | 146 | 50.5 | 80 | 129/138 |
40 | | 159 | 50.5 | 120 | 139/159 |
50 | | 191 | 64 | 120 | 159/186 |