Welcome Customer !

Membership

CHENGDU DATANG COMMUNICATION CABLE CO.,LTD,
Free Member ·1YRS
,
Other

Main Products: 电线电缆

Xwboo>Products

CHENGDU DATANG COMMUNICATION CABLE CO.,LTD,Free·1YRS

  • E-mail

    oversea@datangcable.com

  • Phone

    +86-28-65492890

  • Address

    0, Xixin Road, High-tech District, Chengdu, China. 611731

Contact Now

GYFTC8A

Model
Nature of the Manufacturer
Other
Product Category
Stranded Loose Tube Cable
Place of Origin
City, Province
Overview
Short Description: Single mode fibers(ITU-T G 652 B)6 Fibers in each stranded loose tubeFilling water-blocking compound in cable coreDouble-side plastic coated AL tapeStranded seven galavanised steel wiresTracking resistance PE outer sheath
Product Details

Applications

This product can be used as outdoor transmission lines in core network (for example, long haul and relay lines between local telecommunication centers). It can also be used as outdoor distribution lines or feeder in access network.

Dimensions of optical fiber cable

Number of fibers

Unit

8

16
Strength member Fibre Reinforce Plastic
Number of tube stranding layer

single

Outer diameter

(mm)

19.5/11.3

Outer diameter of stranded wires

(mm)

1.0*7

Number of tube

ea

2

3
Number of Fibers per tube

6

The thickness of cable outer sheath

(mm)

1.7

Cable Weight

(kg/km)

170

Max allowable installing Load

(kN)

4.5

Nominal Delivery Length per Reel

m

2000

Optical characteristic of optical fiber cable

Parameters

Unit

Specifications

Attenuation

1310 nm

dB/km

≤0.35

1550 nm

≤0.22

Attenuation uniformity

1550nm

dB/km

≤0.10

Point Discontinuities

1310 & 1550 nm

dB

≤0.05

Attenuation Vs

Wavelength

1285 ~ 1330 nm

dB/km

≤0.05

1525 ~ 1575 nm

dB/km

≤0.03

Mode Field Diameter

1310 nm

um

9.2 ±0.4

1550 nm

um

10.4 ±0.5

Cable cutoff Wavelength (λcc)

nm

≤1260

Dispersion

1288 ~ 1339 nm

ps/(nm.km)

≤3.5

1550 nm

≤17.5

Zero dispersion

wavelength

nm

1302 ~ 1322

Zero dispersion

slope

ps/(nm2.km)

≤0.091

Polarization Mode

Dispersion (PMD)

1550 nm

ps/km1/2

<0.2

Micro bending60mm, 100 turns

dB

≤0.05 @ 1310mm

≤0.10 @ 1550mm

Parameters

Unit

Specifications

Cladding Diameter

um

125.0 ±0.7

Cladding Non-circularity

%

≤0.8

Core/Cladding Concentricity Error

um

≤0.5

Coating Diameter [Uncolored]

um

245 ±5

Coating Outer Non-Circularity

%

≤6.0

Coating Concentricity Error

um

≤12.5

Fiber Curl

M

≥ 4.0

Parameters

Unit

Specifications

Proof Test Level

Gpa

(Kpsi)

≥ 0.69

(≥ 100)

Coating Strip Force

N

1.3 ~ 8.9

Dynamic Tensile Strength

(Gauge Length: 0.5m)

GPa

Mean value ≥ 4.0

(RH 50%)

Temperature Dependence

(-60℃ ~ +85℃)

dB/km

≤0.05

@1310nm & 1550nm

Temp. -Humidity Cycling

(-10℃ ~ +85℃, 98% RH)

dB/km

≤0.05

@1310nm & 1550nm

Water Immersion @ 23 ±2℃

dB/km

≤0.05

@1310nm & 1550nm

Hot Aging @ 85±2℃

dB/km

≤0.05

@1310nm & 1550nm

Fiber color code

No.

1

2

3

4

5

6

Color

Blue

Orange

Green

Brown

Slate

White

Tube color code

No.

1

2

3

Color

Blue

Orange

Green

Mechanical and environment characteristic test methods

NO

ITEM

TEST METHODSPECIFICATION

1

Tensile strength (IEC 60794-1-E1) - Load: 4500 N- Mandrel dia.: ≤30xcable outer diameter(According to EIA-455-33A)

- Length & Time: 100m & 1 hour

- Loss change (after test) ≤ 0.1 dB- No fiber break- No sheath damage

2

Crush test(IEC 60794-1-E3)- Load: 1000 N- Length: 100 mm- Steel plate: according to EIA-455-41A

- Time: 10 minutes

- Loss change: ≤ 0.1 dB- No fiber break- No sheath damage

3

Impact test

(IEC 60794-1-E4)

- Number of impacts: 20 (Different point)- Impact energy: according to EIA-455-25B- Impact height: 15 cm

- Radius of hammer head: 12.5mm

- Impact rate: 2 sec./cycle

- Loss change ≤ 0.1 dB- No fiber break

- No sheath damage

4

Repeated bending(IEC 60794-1-E6)Bending dia.: 20 x cable outer diameter- Load: comply with EIA-455-104A specification According to cable diameter- Flexing rate: 2 sec./cycle

- No. of cycle: 25

- Loss change: ≤ 0.1 dB-No fiber break

-No sheath damage

5

Twist / Torsion (IEC 60794-1-E7)- Length: 1m- Load: comply with EIA-455-85A specification According to cable diameter- Twist rate: 1min./cycle

- Twist angle: ±180°

- No. of cycle: 10

- Loss change:≤ 0.1 dB

- No fiber break

- No sheath damage

6

Bending test (IEC60794-1-E11) - Mandrel dia.: 20xOD- No. of cycle: 5- Loss change:< 0.1 dB- No fiber break- No sheath damage

7

Compound Flow (IEC60794-1-E14)- Sample length: 30 cm- Temp: 70°C ± 2°C- Time: 24 hours- Weight decrease≤0.005g

8

Temperature Cycling(IEC 60794-1-F1)- Temperature step:+20℃ → -10℃ → +70℃ → +20℃- Number of cycle: 2

- Time per each step: 24 hrs

- Loss change:< 0.1 dB/km- No fiber break- No sheath damage
9Water penetration (IEC60794-1-F5B) - Height of water: 1m- Sample length: 3 m- Time: 1 hour-At the end of 1 hour period,No water shall have leaked fromthe opposite end of the cable

(No drip under inner acket,

Drip between inner

and outer Jacket )

10

Low or HighTemp. Bend Test (EIA/TIA-455-37A)- Temperature: -10°C to + 70°C- Mandrel dia.: 20xOD- Loss change < 0.1 dB

Structure and Mechanical Characteristics of Cable

Number of fibers

Unit

8

16
Strength member Fibre Reinforce Plastic
Number of tube stranding layer

single

Outer diameter

(mm)

19.5/11.3

Outer diameter of stranded wires

(mm)

1.0*7

Number of tube

ea

2

3
Number of Fibers per tube

6

The thickness of cable outer sheath

(mm)

1.7

Cable Weight

(kg/km)

170

Max allowable installing Load

(kN)

4.5

Nominal Delivery Length per Reel

m

2000

Cable Delivery Length

The standard delivery length of a cable is 1000m, 2000m or 3000m with the tolerance 0~+20m. If special requests are made in the contract, the supplied cable length should conform to it.

Characteristics


  • Stranded loose tube cables
  • Similar Product Recommend