The standard structure of GDTS cable is shown in the following table, other structure and fiber count are also available according to customer requirements.
Item | Contents | Value | Remarks |
12 | 24 |
Loose tube | Number | 1 | 2 | |
Outer diameter (mm) | 3.2 | 3.2 | PBT |
Filler | Number | 1 | 0 | Polypropylene |
Fiber count per tube | G.652D | 12 | 12 | |
Power wire | Type | 2.5mm2 | |
Conductor | Copper | Class 1:solid conductors |
Number | 2 | |
Max. DC resistance of single conductor (20℃)(Ω/km) | 7.98 | |
Central strength member | Material | FRP | |
Diameter (mm) | 1.0 | |
PE layer diameter (mm) | 1.6 | |
Water Blocking Material | Material | Water blocking yarn | |
Water blocking tape | |
Armor | Material | PE coated corrugated steel tape |
Outer sheath | Material | MDPE |
Color | Black |
Thickness (mm) | Nominal: 1.8 |
Cable diameter(mm) Approx. | 13.4 |
Cable weight(kg/km) Approx. | 190 |
Main Mechanical and Environmental Performance
Item | Value |
Tensile performance(N) | 1500 |
Crush(N/100mm) | 1000 |
Operation temperature: | -40℃~+60℃ |
Installation temperature | -15℃~+60℃ |
Storage temperature | -40℃~+60℃ |