Mini Current Transformer
Generally used in measuring instruments, as the secondary transformer of the instrument, convert 1 A, 5 A into mA current, For instrument use;
Specifications
Current range:5 - 200 A;
Secondary signal:2 m A- 200 m A;
Withstand voltage rating:2 / 3 KV;
Rated frequency:50 / 60 HZ;
Flame retardant properties:UL 94 - V 0;
Use environment:- 25℃-50℃。
Type A: Dual pins, usually smaller in size and smaller in current range, usually using ultra-fine crystal cores with higher precision;
Type B: Four-pin parallel pins, usually the current is from large to small, usually using ultra-microcrystalline iron core, so the accuracy is higher;
Type C: Front and rear parallel pins, usually the current is from large to small, usually using ultra-microcrystalline iron core, so the accuracy is higher;
Class D: Three-pin, usually use silicon steel wound core, so the accuracy is not as good as the ultra-microcrystalline core, but the load capacity is strong.
Category | Model | Rated input | Recommended turns ratio | load | Accuracy | size |
(Maximum input) | A | B | C | D | Z | P |
A | T | Q | mm | mm | mm | mm | mm | mm |
A | WCT4.5 | 5(20) | 1000 | 10 | 0.2 | 19.2 | 20 | 11 | 4.5 | 12 | |
A | WCT5 | 5(20) | 1000 | 10 | 0.2 | 19 | 18 | 10.5 | 5 | 12 | |
B | WCT5.6 | 5(20) | 1000 | 10 | 0.2 | 19 | 20 | 11 | 5.6 | 6.4 | 15.2 |
B | WCT7 | 5(40) | 2500 | 20 | 0.1 | 23.7 | 24.5 | 11 | 7 | 15/19 | 10 |
B | WCT8.9 | 20(80) | 2500 | 50 | 0.1 | 26.4 | 28.2 | 17 | 8.9 | 15/19 | 16 |
C | WCT7.5 | 10(60) | 2500 | 20 | 0.1 | 23.5 | 24.5 | 11.2 | 7.5 | 18 | 8 |
C | WCT13.2 | 30 (90) | 2500 | 50 | 0.1 | 37.7 | 28.5 | 14 | 13.2 | 24.7/33 | 13 |
D | WCT9.5 | 20 (60) | 1000 | 100 | 1.0 | 23.8 | 23.8 | 11.1 | 9.5 | 15.24 | 7.62 |
D | WCT11.4 | 30(90) | 1000 | 100 | 1.0 | 30.2 | 30.3 | 14.3 | 11.4 | 20.32 | 10.16 |
D | WCT14.6 | S30(150) | 1000 | 100 | 1.0 | 38.1 | 38.1 | 15.9 | 14.6 | 33 | 10.16 |
D | WCT19.05 | 100(150) | 1000 | 100 | 1.0 | 44.5 | 44.5 | 14.3 | 19.05 | 35.56 | 10.16 |
D | WCT23.8 | 8150(200) | 1000 | 100 | 1.0 | 55.6 | 55.6 | 20.6 | 23.8 | 45.72 | 12.7 |

case1:
The typical application circuit is shown as in Fig. 1. The secondary load is basically zero. The precision transformer should be a zero-load transformer. Through the operational amplifier, the user can adjust the value of the feedback resistor R to obtain the required voltage output at the output. The capacitor C and resistor r are used to compensate the phase difference. If the user uses software compensation or does not need to compensate the phase difference, the capacitor C and resistor r can be left unconnected. The operational amplifier in the figure is a general operational amplifier; the accuracy of the feedback resistor R in Figure 1 is related to the accuracy requirements of the output voltage; D 1, D 2 diodes are used for 1 N 4148 protection, and can be left out; C 0 is an anti-interference capacitor The capacitance is determined according to the circuit and operational amplifier technical parameters, otherwise it will cause the output signal to oscillate

Case2:
The typical application circuit is shown as in Fig. 2. And the resistance R can get the output voltage directly. V 0 = R* I 0; R is recommended to use the recommended value, too high will easily saturate. C in Figure 2 can play a role in phase compensation, no phase requirement can be ignore。