Welcome Customer !

Membership

Company Name: Shenzhen gooderly Technology Co., Ltd
Free Member ·1YRS
,
Other

Main Products: 传感器、变送器

Xwboo>Products

OMS20 series double oil water contact switch

Model
Nature of the Manufacturer
Other
Product Category
Oil mixed water switch
Place of Origin
City, Province
Overview
OMS20 series double oil water contact switch
Product Details
Oil water switch product features
This alarm point can be set as the upper limit or lower limit alarm alarm
* each of the alarm point can be adjusted continuously
By the design of cylindrical capacitor, anti electromagnetic interference
Using special chip capacitors, accurate and reliable, small temperature drift
Wide detection range (0%-10%).


Introduction oil mixing switch products
(1) water reacts with oil to form acid, gelatin and oil sludge.
It reduces the lubricity and accelerates the wear of high stress components.
(3) it causes the bond of the control valve or the damage of the other low pressure parts.
(4) corrosion and corrosion of metal. Therefore, we must strengthen the monitoring of oil and water, the user can timely detection and treatment of oil, to ensure the normal operation of the unit and system.

Oil mixing principle of switching
Oil water sensor OMS switch is a cylindrical capacitor, cylindrical capacitor of the formula is: C=2. /.L/. PI epsilon epsilon (ln.R - /R up)
Among them, the other is epsilon = 8854 10 '- as   (vacuum dielectric constant);
R = dielectric constant of the medium between the poles,
The height of the L= cylinder;
The outer diameter of the R1= inner electrode;
R2 = inner diameter of the outer electrode.
For each specific product, in addition to R (dielectric constant between the two media) outside of the parameters have been fixed.

Under normal circumstances, the measured medium for pure oil, that is water content of 0%, then r = epsilon (oil) is a fixed value, when the water containing oil, because the dielectric constant of water is much greater than the oil, then r = epsilon (oil water) will change that is to say, if the column type capacitance sensor in the liquid water content changes, the dielectric constant changes, then the sensor capacitance is changed, the capacitance value with much variation of water content, OMS oil mixing switch circuit part by measuring the capacitance value can be calculated with liquid water. When the oil content reaches the set value, OMS oil output alarm signal contact switch. The advantage of this cylindrical capacitance sensor is to solve the shielding problem of electromagnetic field. The measured results are accurate, accurate, and temperature drift is small, which is not affected by external environment.
OMS double contact oil mixing controller technology parameters
1. power supply voltage: DC24V + 10%, AC/DC110V/220V (85 ~ 264VAC, 120 ~ 370VDC)
2. range: water content is 0 ~ 10%
3. connection output: 1-2 5A/250VDC, 5A / 30VDC
4. analog output: 4-20Ma or 1-5V
5. power consumption: < 1W
6. resolution: 0.1% 7. repeatability: less than 1%

7. repeatability: less than 1%
8. temperature drift: 0.03%/ C
9. operating temperature: 0~100 centigrade
10. electrical wiring: PG9 sealing joint,
11. sensor material: SUS304/316, brass
12. working pressure: < 2Mpa
13. protection grade: IP65