800X Differential Pressure Bypass Balance ValveProduct overviewProduct model: 800XNominal diameter: DN40~1600mmNominal pressure: PN1.0~2.5MPaApplicable medium: water, oil, sea water, sewageApplicable temperature: 0~80℃Structure length standard: GB/T12221-2005Standard of connection flange: GB/T9113Pressure and temperature grade: GB/T12224-2005Test inspection standard: GB/T13927-2008
800X Differential Pressure Bypass Balance Valve introduction
800X Differential Pressure Bypass Balance Valve produced and sold by Baigang valve group is used for air conditioning system to supply / return to balance the pressure difference between the valve. Red Valve Differential Pressure Bypass Balance Valves increase system utilization, maintain accurate, constant pressure drops, and minimize system noise and damage caused by excessive pressure drops. Differential pressure bypass valve is superior to other balance valve where there is no actuator, completely by the pressure of the media itself to achieve the balance of system functions, energy saving and installation space, is an intelligent valve.
800X Differential Pressure Bypass Balance Valve structure characteristics
800X Differential Pressure Bypass Balance Valve produced and sold by Baigang valve group is superior to other balance valve where there is no actuator, completely by the pressure of the media itself to achieve the balance of system functions, energy saving and installation space, is an intelligent valve.
800X Differential Pressure Bypass Balance Valve principle
800X Differential Pressure Bypass Balance Valve are valves used to balance the pressure differential between the supply / return water of the air conditioning system. The valve increases system utilization, maintains accurate, direct pressure drops, and minimizes system noise and equipment damage caused by excessive pressure drops. Differential pressure balance valve is superior to other balance valve is that it has no actuator, the pressure of the complete media itself to balance the function of the system to save energy and installation space, is an intelligent valve.
800X Differential Pressure Bypass Balance Valve main technical parameters
Nominal pressure (Mpa) | Shell test pressure (MPa) | Seal test pressure (MPa) | Suitable media | Medium temperature (℃) |
1.0 | 1.5 | 1.1 | Water | 0 to 80 (diaphragm type) 0 to 200 (piston type) |
1.6 | 1.76 | 2.4 |
2.5 | 2.75 | 3.75 |
800X Differential Pressure Bypass Balance Valve connection size
Nominal diameter (mm) | Size (mm) |
L | H1 | H |
20 | 150 | 126 | 520 |
25 | 160 | 126 | 520 |
32 | 180 | 126 | 520 |
40 | 200 | 160 | 610 |
50 | 203 | 160 | 610 |
65 | 216 | 180 | 625 |
80 | 241 | 200 | 642 |
100 | 292 | 270 | 750 |
125 | 330 | 310 | 808 |
150 | 356 | 320 | 864 |
200 | 495 | 370 | 1135 |
250 | 622 | 430 | 1185 |
300 | 698 | 480 | 1325 |
350 | 787 | 525 | 1385 |
400 | 914 | 580 | 1445 |
450 | 978 | 635 | 1445 |