Post-treatment ultra-purification system
Ion exchange resin uses H + exchange to remove cations in the water, and OH- exchange to remove ions in the water. The H + and OH- replaced in the resin combine to form H2O. Special polishing resin for ultrapure water, its water resistivity can reach 18.2MΩ.cm.
Ion exchange is a traditional, mature process desalination equipment. Due to different equipment structures and technologies, such equipment can produce desalinated water, pure water, high-purity water, and ultra-pure water. Widely used in various industries such as electronics, machinery, chemical industry, shipping, food and beverage and medicine. According to the user's source water quality and water standards, various types of beds can be combined in various ways to meet the user's water quality standards. The control system can be divided into automatic and manual. The principle of ion exchange is that under certain conditions, functions such as softening, alkali removal, and salt removal can be achieved by relying on the exchange of certain ions of the ion exchanger (resin) itself with the isoelectric ions in the water to be treated.
Ultraviolet sterilization device: dual-wavelength ultraviolet sterilization device imported from the United States, UV effective wavelength: UV-185 / 254nm, life can be up to 9000 hours.
UF ultrafiltration device: cutoff molecular weight 5000DaIton, life can be up to 2-3 years.
Terminal microfiltration device: imported from Germany, the terminal microfiltration pore diameter is 0.2 micron, and the life can be as long as 1-2 years.
4.function introduction
Four-level purification device for source water (removal: particulate matter, iron, manganese, residual chlorine, calcium, magnesium ions, adsorbed organic matter, odor, etc.);
Automatic protection of source water at low water pressure;
220V / 50Hz power supply, voltage fluctuation rate ± 10%.
Working conditions: water temperature 5-40 ℃, (north area needs antifreeze room).
Source water indication
The system automatically flushes in 18 seconds when it is turned on;
The system automatically flushes for 15 seconds if the discharge exceeds the standard;
Automatic flushing of reverse osmosis membrane in 15 seconds;
Consumable replacement alarm;
Water tank full indication;
RO pure water (2-10μs / cm)
UP ultrapure water resistance online monitoring; (≥18.25MΩ.cm)