Power Control Unit DY-KZ Series Power Control Unit
DY-KZ28-800-1
This product integrates dischargecircuit, charge circuit and shunt circuit to regulated five solar cell arrayswith combined array design. For each array, regulated capacity is 5A. Fordischarge circuit, regulated capacity is 800W at the efficiency of 92%. This canrealize the follow-up charge for energy storage products.
DY-KZ28-2500-1
This product integrates dischargecircuit, charge circuit and shunt circuit to regulated ten solar cell arrayswith combined array design. For each array, regulated capacity is 10A. Fordischarge circuit, regulated capacity is 2,500W at the efficiency of 88%. Thiscan realize the current Limit charge for energy storage products. The currentsubject to this Limit is 0-20A.
DY-KZ28BS-4000-1
This product integrates discharge circuit, charge circuit andshunt circuit. It consists of regulated bus and unregulated bus. The voltage ofregulated bus is 28V. Unregulated bus corresponds to H2-Ni and Li-ionbatteries, and its voltage can be adjusted to needs. Charge and discharge shuntcapacity can be expanded according to needs. The slave computer for powersource is employed to select 1553B bus or CAN bus according to needs.
DY-KZ42-3000-1
The control circuits S3R, BCR, BDR, TM/TC and MEA areclassified in terms of functional module, and arranged mainly in power controlunit. Moreover, it employs high accuracy PI integrated with MEA controltechnology, and frequency limiting modulation for shunt, so as to modulatemultiple solar cell arrays. Meanwhile, it performs charge management andaccurate control of Li-ion battery. Power control unit employs the architectureof modular integration to combine and expand S3R, BDR/BDR, BCR/BDR, TM/TC, MEAand other modules according to general power. The bus interfaces for externalcommunications are optional.
| Item | DY-KZ28-800-1 | DY-KZ28-2500-1 | DY-KZ28BS-4000-1 | DY-KZ42-3000-1 |
| Output Voltage (V) | 28V | 28V | 28TR bus for platform, adjustable according to needs | 42v |
| Input Voltage (V) | 19-27V | 19-27V | 21-28V | 26-38v |
| Output Power (W) | 800W | 2500w | 4000W | 3200w |
| Discharge Regulation Efficiency (%) | 92% | 88% | 91% | 94% |
| Single Shunt Capacity (A) | 5A | 10A | 5A | 7A |
| Shunt Stages (Stage) | 8 | 10 | 10 | 24 |
| Charge Current Limit (A) | 18-24A | 0-20A | - | 0~16A |
| Battery Charge Stop Control | T-V curve control and slave computer ampere-hour meter control | V-T curve control | MH-Ni battery employs hydrogen pressure and ampere-hour meter control while lithium-ion battery utilizes constant current/voltage control | Li-on battery constant voltage and current limiting charge |
| Output Ripple (mV) | ≤350mV | ≤400mV | ≤400mV | ≤500mV |
| Power Dissipation | ≤16W | ≤24W | ≤35W | ≤40W |
| Weight (kg) | 18.3±0.2kg | 31±0.2kg | 21±0.2kg | 30±0.5kg |
| Dimension (L×W×H) (mm) | 385×300×210mm | 520×302×245mm | 431×300×214mm | 484×420×203mm |
| Designed Lifetime(a) | 5a | 8a | 8a | 15a |