Welcome Customer !

Membership

N-Tech Environmental Protection Science And Technology (Changzhou) Co., Ltd.
Free Member ·1YRS
ChangZhou,JiangSu
Manufacturer

Main Products: Nanofiltration Membrane|Reverse Osmosis Membrane

Xwboo>Products
Product Categories

N-Tech Environmental Protection Science And Technology (Changzhou) Co., Ltd.Free·1YRS

  • E-mail

    entai@n-techcz.com

  • Phone

    0519-85289755

  • Address

    No. 200, Fenglin South Road, Wujin High-tech Industrial Development Zone, Changzhou City

Contact Now

BW series

Model
Nature of the Manufacturer
Manufacturer
Product Category
Place of Origin
ChangZhou City, JiangSu Province
Overview
A classic membrane product suitable for medium salinity (TDS range: 2000mg/L-1 0000mg/L) water quality desalination and medium and low pressure operation, the product is widely used in pure water production, brackish water desalination, groundwater desalination , advanced treatment of reclaimed water reuse and other fields.
Product Details

Product Features

  • High salt rejection and large water flux
  • Unique technical formula, the film surface is white and defect-free
  • Precise control of production to ensure product consistency during mass production
  • Unique post-processing technology for longer service life

 

Applicable scenarios:

A classic membrane product suitable for medium salinity (TDS range: 2000mg/L-1 0000mg/L) water quality desalination and medium and low pressure operation, the product is widely used in pure water production, brackish water desalination, groundwater desalination , advanced treatment of reclaimed water reuse and other fields.

 

ModelAverage water production
(GFD)
(m3/d)
Stable salt rejection
(%)
Effective film area
(ft2)
Water inlet screen thickness
(mil)
BW-804010500 (39.8)99.540031
BW-40402400(9)99.77831
Test conditionTest pressure: 225psiTest solution temperature: 25℃  
Solution concentration: 2000ppmNaClPH value of test solution: 7-8  
15% recovery rate   

Note: Limits of use: Maximum operating pressure is 600psi
The product desalination rate is the stable desalination rate after testing under the standard conditions of 30min; the water production is based on the water production index of NaCl as the test liquid, and the water production fluctuation range is +15%.

 

Notes:

The water yield listed in the table is the average value, and the water yield error of a single membrane element is within ±20%.

The test conditions are not the best conditions for use, please consult our technical staff for details.

The membrane element is equipped with a pressure vessel with a nominal inner diameter of 2.5/4/8 inches.

Before the RO system starts, the system pretreatment and debugging, membrane element filling, instrument calibration and other system tests should be completed.

The water inlet of the membrane element should gradually increase the pressure, and the time to increase the pressure to the normal operating state should not be less than 60 seconds.

The newly installed membrane should be rinsed at low pressure for more than two hours, and the RO pure water should be discharged.

Be careful to avoid back pressure on the product water side, the pressure on the product water side is not greater than 5PSI of the pressure on the water inlet side.

All membrane elements have been rigorously tested before leaving the factory, and are packaged with dry film technology, and the outer packaging is a reinforced cardboard box.

Do not add any chemicals that affect the membrane elements during storage and operation. Consult the latest version of the technical manual, design guide, or consult a technical expert.

If the customer does not operate according to the standard process, he will not bear all the consequences arising therefrom.

Due to technical improvements and product updates, product information may be changed at any time without prior notice. Please pay attention to the latest product information.

The data and information provided by the company in this material are obtained through long-term experiments. We believe that these data and information are accurate and effective. However, due to the user's use methods, conditions of use and applicable laws, it may vary from time to time. It is not responsible for the consequences and losses caused by the use of the data and information of this product and its samples, regardless of whether it is used alone or in conjunction with other products. It is recommended that users conduct their own experiments to determine their safety and whether they are suitable for the user's specific use. Purpose.

 

Important Information

1. Before the membrane element is installed, the system and pipeline should be thoroughly cleaned to ensure that there is no damage to the membrane caused by any mechanical impurities.

2. Before running the system, it should be ensured that the preprocessing and debugging are completed.

3. During the startup, shutdown, cleaning and other processes of the system, the water inlet should be slow, from low pressure to high pressure, from low flow to large flow, to avoid impact damage to the membrane element due to the instantaneous increase of pressure and flow.

4. The membrane element should always be kept wet once water enters.

5. Avoid back pressure on the permeate side at all times.