Welcome Customer !

Membership

Shangou Valve Co, Ltd.
Free Member ·1YRS
WenZhou,ZheJiang
Manufacturer

Main Products: valve,

Xwboo>Products

Shangou Valve Co, Ltd.Free·1YRS

  • E-mail

    59778276@qq.com

  • Phone

    0577-67975099

  • Address

    No. 430, Zhangbao North Road, Anfeng Industrial Zone, Oubei, Wenzhou, Zhejiang Province

Contact Now

SD941-16Type a electric telescopic butterfly valve

Model
Nature of the Manufacturer
Manufacturer
Product Category
Butterfly Valve
Place of Origin
WenZhou City, ZheJiang Province
Overview
SD941-16The type-1 electric telescopic butterfly valve is applicable to the water supply and drainage and gas pipelines of food, medicine, chemical industry, petroleum, electric power, light textile, papermaking and other water supply and drainage and gas pipelines with the temperature ≤ 80 ℃ and the nominal pressure ≤ 1.6Mpa. It has the function of compensating the thermal expansion and cold contraction of the pipeline.
Product Details
Product overview

SD941-16The type-1 electric telescopic butterfly valve is applicable to the water supply and drainage and gas pipelines of food, medicine, chemical industry, petroleum, electric power, light textile, papermaking and other water supply and drainage and gas pipelines with the temperature ≤ 80 ℃ and the nominal pressure ≤ 1.6Mpa. It has the function of compensating the thermal expansion and cold contraction of the pipeline.

Product features

1. The design is novel, reasonable, unique in structure, light in weight, convenient in operation and quick in opening and closing;
2. The telescopic butterfly valve can not only adjust and cut off the flow, but also compensate for the expansion and cold contraction caused by the temperature difference of the pipeline, but also provide convenience for the installation, replacement and maintenance of the valve.
3. The sealing parts can be adjusted and replaced, and the sealing performance is reliable.

 

Parts material
SD941-16Main parts and components materials of type-A electric telescopic butterfly valve
nameMaterial Science
valve bodyWCB、ZG1Cr18Ni9Ti、ZG1Cr18Ni12Mo2Ti、HT250
Valve plateWCB、ZG1Cr18Ni9Ti、ZG1Cr18Ni12Mo2Ti、HT250
Stem1Cr18Ni9Ti、1Cr18Ni12Mo2Ti、2Cr13
seal ringCR、NBR、EPDM、FPM
fillerNBR、Flexible graphite, V-type rubber
Standards adopted

Design standards: GB / t12238-1989; JB / t8527-1997;
Flange connection size:
GB/T9113.1-2000;GB/T9113.2-2000;
GB/T9115.1-2000;GB/T9115.2-2000;
Structural length: GB / t12221-1989;
Pressure test: GB / t13927-1992; JB / t9092-1999;

Actuator parameters

1. Power supply: the motor is three-phase AC, 380V (special order 660V, 440V or 220 V), 50 Hz (special order 60 Hz); control line voltage is 220 V / 50 Hz (special order 60 Hz); remote control voltage is 24 VDC.
2. Ambient temperature: - 20 - + 60 ℃ (special order - 60 - + 80 ℃);
3. Relative temperature: ≤ 90% (at 25 ℃);
4. Ordinary type and outdoor type are used in places without inflammable / explosive and corrosive medium; explosion-proof products are D Ⅰ and D Ⅱ BT4, D Ⅰ is suitable for non excavation working face of coal mine; D Ⅱ BT4 is used in factory, which is suitable for explosive gas mixture of class Ⅱ A and Ⅱ B T1-T4;
5. Protection grade: IP55 for outdoor type and explosion-proof type (IP67 can be customized);
6. Working system: short time 10 minutes (30 minutes can be customized);

technical parameter

SD941-16Main technical parameters of type a electric telescopic butterfly valve

Nominal diameterDN(mm)50~2000
Nominal pressurePN(MPa)0.61.01.6
Test pressurestrength test0.91.52.4
Sealing test0.661.11.76
Airtight seal test0.60.60.6
Applicable temperature≤80℃
Applicable temperatureAir, water, steam, gas, oil, etc.
Driving formManual, worm gear drive, pneumatic drive, electric drive.
Connection size
SD941-16Connection dimension of external structure of type-1 electric telescopic butterfly valve(mm)
Diameter(DN)LLMAXLMIND1DZ-ΦdHH0ABD0Wt/kg
501501631381251654-1882.54451251258061
651701881521451854-1892.54651251258074
801801921621602008-181004801251258088
1001902251801802208-1811050512512580100
1252002351902102508-18125700325245150120
1502102401952402858-22142.5735325245150125
2002302652152953408-22170805325245150180
25025028523535039512-22197.5890363313200205
30027030225240044512-22222.5950363313200260
35029032127146050516-22252.51020363313250420
40031034328351556516-26282.51105363313250520
45033036030056561520-26307.51287465439300660
50035038032062067020-263351185546431360700
60039042536572578020-3039013305465563601020
70043046539584089524-30447.514355465563601140
800470510430950101524-33507.515455465563601380
9005105604601050111528-33557.518006176173602100
10005506005001160123028-3661523656326323602520
12006306805801380145532-39727.525856326323603100

Note: 1. The sealing test pressure of the above butterfly valves is 1.0MPa for dn50-dn800, 0.6MPa for dn900-dn1000, and 0.25MPa for dn200-dn2000.
2. If the working pressure exceeds 1.0MPa, triple eccentric butterfly valve is recommended.
3. The connection dimensions of the above butterfly valves shall be manufactured according to the standard of 1.0MPa; in case of special needs, it shall be indicated when ordering.

matters needing attention

1. Before installation, check whether the specification, pressure, temperature and corrosion resistance of butterfly valve meet the use requirements. Check whether the parts are damaged or loose.
2. The butterfly valve can be installed on the pipeline at any angle and should be closed; when welding the pipe flange, the valve sealing port should be blocked with a plate to prevent particles and sundries from damaging the sealing surface. After welding, take down the valve, clean the valve sealing surface and pipe cavity, and then install the fixed valve.
3. Please pay attention to the pressure bearing direction when the valve is closed.
4. Before installation, the sealing surface (sealing surface at both ends, sealing surface of butterfly plate and sealing surface of valve seat) shall be thoroughly cleaned to remove dust and dirt.
5. Before installation, the butterfly valve should be air tested, and the opening and closing position should be flexible, and the opening and closing position should be consistent with the position indicated by the pointer.
6. Manual operation, clockwise is off, counter clockwise is on, pointer indication is in place, it is not allowed to open and close the valve with additional force.
7. During the pressure test of the valve, it is not allowed to use single flange for installation and pressure test, but double flange installation and pressure test must be adopted. The test pressure shall comply with GB / T13927-92.
8. The bolts shall be tightened symmetrically and alternately instead of separately.
9. The limit screw has been adjusted before delivery, so it is not allowed to adjust it easily. Please refer to the manual for electric drive device.
10. When the electric butterfly valve leaves the factory, the opening and closing stroke of the control mechanism has been adjusted. In order to prevent the wrong direction when the power supply is connected, the user should first manually open it to the half open position before connecting the power for the first time, and then press the inching switch to check that the direction of the indicator wheel is consistent with the opening direction of the valve.
11. If the valve is found to be open and closed abnormally, the cause shall be found out for repair and elimination, so as to prevent the valve from being damaged due to opening and closing by means of applying force.