Q941FElectric flange regulating ball valvePN16~PN40

Model
Nature of the Manufacturer
Manufacturer
Product Category
Ball Valve
Place of Origin
WenZhou City, ZheJiang Province
Overview
It has the advantages of simple connection, compact structure, small size, light weight, small resistance, stable and reliable action. The actuator can be equipped with UNIC, PSQ, HQ, DHL and other types of electronic electric actuator according to user requirements.
Product Details
Product overview

Q941FThe electric flange regulating ball valve PN16 ~ PN40 is suitable for two position adjustment and cut-off. The valve is directly connected to the actuator. The electric actuator has a built-in servo system, and there is no need to install a servo amplifier. The operation can be controlled by inputting 4-20mA signal and 220VAC power supply. It has the advantages of simple connection, compact structure, small size, light weight, small resistance, stable and reliable action. The actuator can be equipped with UNIC, PSQ, HQ, DHL and other types of electronic electric actuator according to user requirements.

technical parameter
Q941FMain technical parameters of electric flange regulating ball valve PN16 ~ PN40
Test pressure (Mpa)Nominal pressure(Mpa)Pressure level(class)JIS(Mpa)
1.62.54.06.410.015030060010K20K
strength test2.43.86.09.615.03.17.815.32.43.8
Sealing test1.82.84.47.011.02.25.611.21.52.8
Air tightness test0.5~0.7
Technical index

Control accuracy: 0.1% - 3.0% (adjustable through U4 parameters)
Feedback signal of accessible electric actuator: potentiometer 500 Ω - 10K Ω
Can receive external control signal (DC): 4-20mA (1-5V, 0-10V, switch value, etc. customized before delivery)
Input impedance: 250 Ω;
By modifying U1 parameter, it can be set as follows: ① dRTA / forward action, rvsa / reverse action mode; ② when input signal is interrupted, "interrupt" mode - open, stop, shut
Optional: ① thyristor output (AC, 600V, 25a); ② relay output (AC, 250V, 10a) 〕 specify when ordering
Output actuator position signal: low drift output 4-20madc corresponding to actuator fully closed to fully open, signal completely isolated from input (photoelectric isolation), output load ≤ 500 Ω
Ambient temperature: 0-70 ℃, humidity: 35-85%
With over temperature protection function: when the temperature in the positioner shell is higher than or equal to 70 ℃, the positioner will stop the opening and closing control of the actuator
The action range of the actuator corresponding to the input signal can be freely calibrated by pressing the key (generally, it is calibrated as the fully closed and fully open position of the electric actuator)

Parts material
Q941FMain parts and components materials of electric flange regulating ball valve PN16 ~ PN40
Part nameMaterial Science
valve bodyWCBZG1Cr18Ni9TiCF8 (304)CF3 (304L)ZG1Cr18Ni12Mo2TiCF8M(316)CF3M (316L)
Ball, stem2Cr131Cr18Ni9Ti0Cr19Ni9 (304)00Cr19Ni11 (304L)1Cr18Ni12Mo2Ti0Cr17Ni12Mo2 (316)00Cr17Ni12Mo2 (316L)
seal ringPolytetrafluoroethylene (PTFE), reinforced polytetrafluoroethylene (PPL), para polyphenylene flexible graphite
 Water, gas, steam, oil, etcCorrosive medium such as nitric acidStrong oxidizing mediumAcetic acid and other corrosive media
Executive Standards

1. Design and manufacture: gb12237-89, api608, API 6D, JPI 7s-48, BS5351, din3357.
2. Flange dimensions: JB / t74-90 (jb74-90), gb9112-9131, hgj44-76, sh3406, ANSI B16.5, JIS b2212-2214, NF e29-211, din2543.
3. Structural length: gb12221-89, ANSI B16.10, JIS B2002, NF e29-305, din3202.
4. Main test: JB / T 9092, API 598.

structure size

 

Q941FMain dimensions of electric flange regulating ball valve PN16 ~ PN40(mm)
Nominal pressureDNLDHL1D1bZ-d1H1
pressure1.6/2.5/4.01.6/2.5/4.0  1.6/2.5/4.01.6/2.5/4.01.6/2.5/4.0 
15130/130/140952751576514/16/164-1448
20140/140/1501052801577514/16/164-1453
25150/150/1651152871578514/16/164-1458
32165/165/18013535420810016/16/184-1868
40180/180/20014531220811016/16/184-1873
50200/200/22016032520812516/20/204-1880
65220/220/25018033525614518/22/224-18/8-18/8-1890
80250/250/28019536525616020/22/228-1898
100280/280/320215/230/230400256180/190/19020/24/248-18/8-23/8-23120
125320/320/360245/270/270420256210/220/22024/28/308-23/8-25/8-25140
150360/360/400280/300/300440256240/250/25024/28/308-23/8-25/8-25167
200400/400/550335/360/375470256295/310/32026/34/3812-23/12-25/12-30210
250630 750405 470545380    
300750 870460 530580380    

 

matters needing attention

1. Be careful in installation and construction, and do not hit the valve.
2. Before installation, the ball valve should be inspected to check the specification and model, and identify whether there is damage, especially for the valve stem. Turn it a few times to see if it is skewed, because Zui is prone to bump the stem during transportation. Also remove the debris in the valve.
3. When lifting the ball valve, the rope should not be tied to the hand wheel or the valve stem to avoid damage to these parts, but should be tied to the valve body.
4. The pipeline connected to the ball valve must be cleaned. Compressed air can be used to blow away iron oxide chips, mud and sand, welding slag and other impurities. These debris, not only easy to scratch the sealing surface of the ball valve, in which large particles of debris (such as welding slag), but also block the small valve, so that its failure.
5. The position of valve handle rotation should be reserved during installation. 6. The ball valve cannot be used as throttling. 7. The ball valve with transmission mechanism shall be installed vertically.