The butterfly valve can be axially retracted in a certain range, and can also overcome the offset caused by the pipe docking with different shafts in a certain angle range. It has automatic compensation for the thermal expansion and cold contraction of the pipeline, which greatly facilitates the installation and disassembly of the valve pipeline. It can be used in petroleum, chemical, electric power, papermaking, food, beverage, pharmaceutical pure pipeline and industrial environmental protection, water treatment, ......
Product overview
SD341XExpansion flange butterfly valve is used in petroleum, metallurgy, chemical industry, electric power, medicine, food, light textile, ship, municipal engineering and water supply and drainage system. It is suitable for the general corrosive, non corrosive gas, liquid, semi fluid, solid powder and other media for closure and regulation control. It can also be used for the transformation of old pipelines, maintenance and replacement of matching valves.
Nominal pressure PN(Mpa) | Test pressureMPa | working pressure MPa | working temperature (℃) |
| seal up | strength |
1.0(10) | 1.1 | 1.5 | 1.0 | -46℃-135℃ |
Working principle and structure description
SD341XThe expansion flange butterfly valve is a flange connection. Its main feature is that the structure length can be expanded and extended, which is conducive to be installed on the long pipe to absorb the heat expansion and cold contraction or balance the vibration influence of the pipeline. Because of the long expansion space, the expansion device is omitted. The valve adopts rubber soft seal with good sealing performance, and has the characteristics of simple structure, light weight, short connection size, large flow rate, small liquid resistance and convenient maintenance.
The main parts of the valve are valve body, expansion pipe, butterfly plate, sealing ring, valve stem and actuator. When using, rotate the hand wheel clockwise to close and counterclockwise to open.
Material of main parts
| Part name | Material Science | Part name | Material Science |
valve body | Cast iron / cast steel | Sealing ring pressing plate | Q235 |
Telescopic tube | Cast iron / cast steel | Stem | 2Cr13, 45 |
Disc | Cast iron / cast steel | seal ring | Oil resistant rubber |
Main shape and connection dimension
SD341X-10、SD941X-10 Main dimensions:
| Specifications | minimum L1 | middle L | Longest L2 | D | D1 | D2 | H1 | H2 | Z-φd |
100 | 174 | 195 | 216 | 215 | 180 | 155 | 110 | 170 | 8-φ18 |
125 | 186 | 209 | 232 | 245 | 210 | 185 | 123 | 185 | 8-φ18 |
150 | 194 | 216 | 239 | 280 | 240 | 210 | 140 | 210 | 8-φ23 |
200 | 214 | 239 | 264 | 335 | 295 | 265 | 170 | 238 | 8-φ23 |
250 | 260 | 276 | 296 | 390 | 350 | 320 | 195 | 270 | 12-φ23 |
300 | 250 | 275 | 300 | 440 | 400 | 368 | 222 | 300 | 12-φ23 |
350 | 270 | 295 | 320 | 500 | 460 | 428 | 252 | 330 | 16-φ23 |
400 | 280 | 307 | 330 | 565 | 515 | 482 | 285 | 368 | 16-φ25 |
450 | 305 | 330 | 355 | 615 | 565 | 532 | 310 | 402 | 20-φ25 |
500 | 315 | 340 | 365 | 670 | 620 | 585 | 337 | 438 | 20-φ25 |
600 | 370 | 395 | 420 | 780 | 725 | 685 | 393 | 490 | 20-φ30 |
700 | 396 | 421 | 446 | 895 | 840 | 800 | 450 | 558 | 24-φ30 |
800 | 426 | 451 | 476 | 1010 | 950 | 905 | 515 | 625 | 24-φ34 |
900 | 456 | 481 | 506 | 1110 | 1050 | 1005 | 560 | 685 | 28-φ34 |
1000 | 466 | 491 | 516 | 1220 | 1160 | 1115 | 610 | 750 | 28-φ34 |
1200 | 510 | 535 | 560 | 1450 | 1380 | 1325 | 725 | 880 | 32-φ41 |
1400 | 540 | 565 | 590 | 1675 | 1590 | 1525 | 840 | 987 | 36-φ48 |
1600 | 585 | 608 | 630 | 1915 | 1820 | 1750 | 960 | 1158 | 40-φ54 |
1800 | 630 | 655 | 680 | 2115 | 2020 | 1950 | 1060 | 1258 | 44-φ54 |
2000 | 680 | 705 | 730 | 2325 | 2230 | 2160 | 1165 | 1365 | 48-φ54 |
Precautions for installation, use and maintenance
- The valve is not allowed to be smashed in the process of transportation, so as to avoid damaging the sealing surface.
The valve should be stored in a cool and dry place for a long time. The valve plate should be opened at 5 ° to 10 ° state. Both ends should be blocked and covered. If there is a packing box, the valve can be placed overlapped.
The following work should be done before valve installation
Wipe off the dirt attached on the valve;
Check whether the working condition is consistent with the valve working pressure, working temperature and corrosion resistance;
Check whether the parts of the valve are loose or damaged;
The manual opening and closing of the valve shall be flexible and free of jamming;
This kind of valve is allowed to be installed in any position, angle and open air. If there is no special description in the order contract, the electric valve can only be installed vertically and indoors.
The valve can be driven by worm gear, or electrically, pneumatically, hydraulically or electrically, pneumatically and hydraulically. When the valve points to 0 ° or 90 ° it indicates that the opening and closing is completed. It is not allowed to open and close the valve forcibly to avoid damaging the machine parts. The two limit screws on the worm gear box have been adjusted before delivery, and they are generally not allowed to be adjusted during use. If necessary, the limit screws should be locked after adjustment.
After the valve is installed, the user can make the maintenance cycle according to the opening and closing frequency, and fill the actuator with lubricating grease according to the cycle.
In case of abnormal opening and closing of the valve, the cause should be found out and eliminated. It is not allowed to use knocking method to force opening and closing.
The valve should be installed according to the nominal length (middle length), not two limit lengths.
When the valve is installed in the pipeline, the valve seat should be coaxial with the pipe, and appropriate gasket should be clamped between the flange at both ends and the valve body flange.
10. The valve should not be installed at the corner or the end of the pipe. When the valve is installed in the middle of the pipeline, the pipeline at both ends of the valve must be fixed and the limit is firm.
11. When the performance test of the valve needs to be carried out on site, it should be carried out according to the provisions of GB / T13927-92. The sealing test includes valve sealing test and expansion part sealing test. In the sealing test of expansion part, the butterfly plate should be closed, and the expansion pipe should be covered tightly with a blind plate which can be injected with medium and connected with the valve itself Bolts shall be used to limit to a certain position, and the maximum position shall not exceed the limit length.
12. The flange sealing surfaces on both sides of the pipeline must be parallel.
13. When tightening the flange bolts, they should be tightened symmetrically and alternately, and should not be tightened separately according to the times.
Possible faults and troubleshooting
| Possible faults | Cause | resolvent |
| Packing leakage | - Packing not compacted
- Insufficient number of packing rings
- Insufficient number of packing rings
| - Tighten the packing gland nuts evenly and compress the packing
- Add filler
- Replacement of packing
|
| Leakage at the joint of valve body and nozzle | - The connecting bolts and nuts are not tightened or tightened unevenly
- Damage or dirt on sealing surface of nozzle
- Damage or failure of O-ring
| - Tighten evenly and crosswise
- Repair the sealing surface or clean up the dirt
- Replace the O-ring
|
| Leakage of sealing surface | 1.There are impurities on the sealing surface 2.Wear of sealing ring 3.The pressing plate is loose | - Remove debris
- Replace the sealing ring
- Tighten the adjusting screws of Part 8 evenly and properly
|
| Replacement of packing | - The packing pressure is too tight, or the packing gland is skewed
- Transmission parts damaged
- The seal ring is aged and creeps
| - Adjust the nuts on the packing gland
- Replace parts
- Replace the sealing ring
|
statement
用户If there are special requirements, it should be stated at the time of ordering. Our factory can design and produce again according to the user's requirements.