Q941FSoft seal electric floating ball valve is a flange connection, floating ball through ball valve. The sealing form is soft seal. The sealing surface of valve seat is made of fluoroplastic, nominal pressure is pn16-pn63, nominal size is DN 15-dn200, applicable temperature is - 28-300 ℃, valve body material is carbon steel or stainless steel, q941f soft seal electric floating ball valve is suitable for two position cut-off and adjustment.
Product description
Q941FSoft seal electric floating ball valve is a flange connection, floating ball through ball valve. The sealing form is soft seal. The sealing surface of valve seat is made of fluoroplastic, nominal pressure is pn16-pn63, nominal size is DN 15-dn200, applicable temperature is - 28-300 ℃, valve body material is carbon steel or stainless steel, q941f soft seal electric floating ball valve is suitable for two position cut-off and adjustment. The valve is directly connected with the actuator, which is composed of fine and small electric actuator (or different types of electronic electric actuator or air piston actuator can be configured according to user requirements) and ultra short ball valve. The electric actuator has a built-in servo system, which can be controlled by inputting 4-20mA signal and 220V AC power supply without additional servo amplifier. Compared with ordinary electric ball valve, it has the advantages of compact structure, small volume, light weight, close distance between valve seat and end face flange, less material retention and superior sealing performance.
performance parameter
Q941FPerformance parameters of soft seal electric floating ball valve
| model | PN | working pressure / MPa | Applicable temperature / ℃ | Applicable media |
| | 16 | 1.6 | -28~300 | Water, steam, oil, etc |
| Q941F-25 | 25 | 2.5 |
| Q941F-40 | 40 | 4 |
| Q941F-63 | 63 | 6.3 |
| Q941F-16P | 16 | 1.6 | Corrosive medium such as nitric acid |
| Q941F-25P | 25 | 2.5 |
| Q941F-40P | 40 | 4 |
| Q941F-63P | 63 | 6.3 |
| Q941F-16R | 16 | 1.6 |
| Q941F-25R | 25 | 2.5 |
| Q941F-40R | 40 | 4 |
| Q941F-63R | 63 | 6.3 |
Parts material
Q941FSoft seal electric floating ball valve parts materials
| model | Material Science |
| valve body | Ball, stem | seal ring | Packing, gasket |
| Q941F-16C | WCB | 2Cr13 | teflon | V-shaped polytetrafluoroethylene, flexible graphite ring, polytetrafluoroethylene sheet, flexible graphite winding gasket |
| Q941F-25 |
| Q941F-40 |
| Q941F-63 |
| Q941F-16P | ZG1Cr18Ni9Ti | 1Cr18Ni9Ti |
| Q941F-25P |
| Q941F-40P |
| Q941F-63P |
| Q941F-16R | CF8 (304) | 0Cr18Ni9 (304) |
| Q941F-25R |
| Q941F-40R |
| Q941F-63R |
结构尺寸
Q941F-16 External structure and dimension of V-type soft seal electric floating ball valve(mm)| DN | L | D | D1 | D2 | b | z×φd |
| 15 | 130 | 95 | 65 | 45 | 14 | 4×φ14 |
| 20 | 140 | 105 | 75 | 55 | 14 | 4×φ14 |
| 25 | 150 | 115 | 85 | 65 | 14 | 4×φ14 |
| 32 | 165 | 135 | 100 | 78 | 16 | 4×φ18 |
| 40 | 180 | 145 | 110 | 85 | 16 | 4×φ18 |
| 50 | 200 | 160 | 125 | 100 | 16 | 4×φ18 |
| 65 | 220 | 180 | 145 | 120 | 18 | 4×φ18 |
| 80 | 250 | 195 | 160 | 135 | 20 | 8×φ18 |
| 100 | 280 | 215 | 180 | 155 | 20 | 8×φ18 |
| 125 | 320 | 245 | 210 | 185 | 22 | 8×φ18 |
| 150 | 360 | 280 | 240 | 210 | 24 | 8×φ23 |
| 200 | 400 | 335 | 295 | 265 | 26 | 12×φ23 |
Q941F-25 External structure and dimension of V-type soft seal electric floating ball valve(mm)| DN | L | D | D1 | D2 | b | z×φd |
| 15 | 130 | 95 | 65 | 45 | 16 | 4×φ14 |
| 20 | 140 | 105 | 75 | 55 | 16 | 4×φ14 |
| 25 | 150 | 115 | 85 | 65 | 16 | 4×φ14 |
| 32 | 165 | 135 | 100 | 78 | 18 | 4×φ18 |
| 40 | 180 | 145 | 110 | 85 | 18 | 4×φ18 |
| 50 | 200 | 160 | 125 | 100 | 20 | 4×φ18 |
| 65 | 220 | 180 | 145 | 120 | 22 | 8×φ18 |
| 80 | 250 | 195 | 160 | 135 | 22 | 8×φ18 |
| 100 | 280 | 230 | 190 | 160 | 24 | 8×φ23 |
| 125 | 320 | 270 | 220 | 188 | 28 | 8×φ25 |
| 150 | 360 | 300 | 250 | 218 | 30 | 8×φ25 |
| 200 | 400 | 360 | 310 | 278 | 34 | 12×φ25 |
Q941F-40 External structure and dimension of V-type soft seal electric floating ball valve(mm)| DN | L | D | D1 | D2 | b | z×φd |
| 15 | 130 | 95 | 65 | 45 | 16 | 4×φ14 |
| 20 | 140 | 105 | 75 | 55 | 16 | 4×φ14 |
| 25 | 150 | 115 | 85 | 65 | 16 | 4×φ14 |
| 32 | 180 | 135 | 100 | 78 | 18 | 4×φ18 |
| 40 | 200 | 145 | 110 | 85 | 18 | 4×φ18 |
| 50 | 220 | 160 | 125 | 100 | 20 | 4×φ18 |
| 65 | 250 | 180 | 145 | 120 | 22 | 8×φ18 |
| 80 | 280 | 195 | 160 | 135 | 22 | 8×φ18 |
| 100 | 320 | 230 | 190 | 160 | 24 | 8×φ23 |
| 125 | 400 | 270 | 220 | 188 | 28 | 8×φ25 |
| 150 | 400 | 300 | 250 | 218 | 30 | 8×φ25 |
| 200 | 502 | 375 | 320 | 282 | 38 | 12×φ30 |
Q941F-63 External structure and dimension of V-type soft seal electric floating ball valve(mm)| DN | L | D | D1 | D2 | b | z×φd |
| 15 | 140 | 105 | 75 | 55 | 18 | 4×φ14 |
| 20 | 152 | 125 | 90 | 68 | 20 | 4×φ18 |
| 25 | 180 | 135 | 100 | 78 | 22 | 4×φ18 |
| 32 | 200 | 150 | 110 | 82 | 24 | 4×φ23 |
| 40 | 220 | 165 | 125 | 95 | 24 | 4×φ23 |
| 50 | 250 | 175 | 135 | 105 | 26 | 4×φ23 |
| 65 | 280 | 200 | 160 | 130 | 28 | 8×φ23 |
| 80 | 320 | 210 | 170 | 140 | 30 | 8×φ23 |
| 100 | 360 | 250 | 200 | 168 | 32 | 8×φ25 |
| 125 | 381 | 295 | 240 | 202 | 36 | 8×φ34 |
| 150 | 403 | 340 | 280 | 240 | 38 | 12×φ34 |
matters needing attention
1. Be careful in installation and construction, and do not hit the valve.
2. Before installation, the ball valve should be inspected to check the specification and model, and identify whether there is damage, especially for the valve stem. Turn it a few times to see if it is skewed, because Zui is prone to bump the stem during transportation. Also remove the debris in the valve.
3. When lifting the ball valve, the rope should not be tied to the hand wheel or the valve stem to avoid damage to these parts, but should be tied to the valve body.
4. The pipeline connected to the ball valve must be cleaned. Compressed air can be used to blow away iron oxide chips, mud and sand, welding slag and other impurities. These debris, not only easy to scratch the sealing surface of the ball valve, in which large particles of debris (such as welding slag), but also block the small valve, so that its failure.
5. The position of valve handle rotation should be reserved during installation. 6. The ball valve cannot be used as throttling. 7. The ball valve with transmission mechanism shall be installed vertically.