HZYN-1166 Lubricating oil low temperature Brookfield viscometer ASTM D2983 ASTM D11145 Low Temperature Brookfield Viscosity Tester
I.Functional Features
◆Precision mandrel, in line with standard requirements, high test repeatability;
◆Using metal bath cold trap;
◆Standard glass test tube, inner diameter 22~22.5mm, length 120mm;
◆Special rotational viscometer, equipped with seven spindle speeds;
◆Semiconductor refrigeration, can be tested after 2 hours of constant temperature, compared with 18 hours of traditional air constant temperature, the efficiency is increased by nearly 90%;
◆Microcomputer temperature controller, PID adjustment, temperature control range: normal temperature ~-40℃, PT100 temperature sensor, high precision;
◆Large viscosity detection range, 1000~1000000mPa.s
◆LCD screen display, programmable selection of test speed, test time, automatic calculation of results;
◆ Equipped with CADON® analysis software, which can calibrate and analyze the linear accuracy of the viscometer very well;
◆One-key automatic lifting structure, automatic positioning of viscometer;
◆The test tube has a locking function to prevent the test tube from affecting the accuracy due to excessive viscosity.
II.Scope of application
◆Lubricant production enterprises
◆Testing department
III.Relevant Standards
◆GB/T11145 "Determination of Lubricant Low Temperature Viscosity (Brockfeldt Viscometer Method)"
◆ASTM D2983 "Determination of Lubricant Low Temperature Viscosity (Brockfeldt Viscometer Method)"
IV.Technical parameters
Model | HZYN-1166 |
trial standard | ASTM D2983 GB/T11145 |
Cooling method | Semiconductor refrigeration |
Temperature control method | Digital PID Temperature Controller |
Temperature control range | Normal temperature~-40±0.1℃ |
range of rotation | 0 5~60r/min |
Operation method | Touch screen operation |
Lifting method | Automatic lift |
Working power | AC220V 50HZ |
Total power | Host: 800W; Low temperature bath: 1200W |
Instrument size | Host: 400*250*700mm; low temperature bath: 435*540*730mm |
net weight | Host: 32KG; low temperature bath: 45KG |
V.Configuration list
NO | name | Specification | quantity |
1 | host | HZYN-1166 | 1 |
2 | test tube |
| 4 |
3 | Standard oil | 100ml | 2 |
4 | test tube stopper |
| 1 |
5 | Spindle No. 4 |
| 1 |
6 | Insurance | 20A | 4 |
7 | Berkefeldt Viscometer |
| 1 |
8 | Circulating cold bath |
| 1 |
9 | plastic syringe | 50ml | 1 |
10 | cooling water pipe | With thermal jacket | 2 |
11 | M5×20 socket head cap screws |
| 2 |
12 | Allen key |
| 1 |
13 | Insulation ring |
| 2 |
14 | plastic pipette |
| 4 |
15 | Software USB Shield |
| 1 |
16 | Software CD |
| 1 |