Model: 600XNominal diameter: DN40 ~ 1600mmNominal: PN1.0 ~ 2.5MPaSuitable medium: water, oil, water, sewageTemperature: 0 ~ 80 ℃Structure length standard: GB / T12221-2005Connection flange Standard: GB / T9113Pressure Temperature Level: GB / T12224-2005Test Standards: GB / T13927-2008
600X electric control valve is a solenoid valve for the pilot valve hydraulic valve. Commonly used in water supply and drainage and industrial systems in the automatic control, accurate and rapid response control, remote control according to the electrical signal to open and close the pipeline system for remote operation.
600X electric control valve and can replace the gate valve and butterfly valve for large electric operating system. Valve closing speed adjustable, closed without pressure fluctuations. The valve is small, light weight, easy maintenance, easy to use, safe and reliable. Solenoid valve optional AC 220V, or DC 24V, according to various occasions, the use of normally open or normally closed can be
600X electric control valve structure features and uses
600X electric control valve consists of main valve, solenoid pilot valve, needle valve, ball valve, microfilter and pressure gauge to form a hydraulic control takeover system. Through the solenoid pilot valve can be opened and closed on the remote control valve. After installing additional devices, you can control the speed of opening and closing. Electrically controlled hydraulic control valve using the pilot valve to open and close the valve to save energy. Can replace other valves large electric devices. Electrically controlled hydraulic control valve products are widely used in high-rise buildings, living areas and other water supply pipe network systems and urban water supply projects.
600X electric control valve works
When the valve from the inlet end of the water, the water flow through the needle valve into the main valve control room, when the solenoid valve is open, the control room of water through the solenoid pilot valve, ball valve out. Ball valve opening is greater than the needle valve opening, the main valve control chamber pressure is very low, the main valve is fully open state.
When the solenoid valve is closed, the main valve control room of the water can not flow out of the control room to boost the diaphragm to close the main valve.
600X electric control valve main technical parameters
Nominal pressure (Mpa) | Shell test pressure (MPa) | Seal test pressure (MPa) | The maximum inlet pressure (MPa) | Export adjustable pressure (MPa) | Suitable media | Medium temperature (℃) |
1.0 | 1.5 | 1.1 | 1.0 | 0.09-0.8 | Water | 0-80 |
1.6 | 2.4 | 1.76 | 1.6 | 0.10-1.2 |
2.5 | 3.75 | 2.75 | 2.5 | 0.15-1.6 |
600X electric control valve main parts materials
Part Name | Parts and materials |
Body valve cover | WCB |
Valve seat disc | Copper alloy |
O-ring seals | Nitrile rubber |
Valve stem | 2Cr13 |
Spring | 50CrVA |
Needle valve | Copper alloy |
Ball valve | Copper alloy |
Solenoid pilot valve | stainless steel |
Micro filter | stainless steel |
Connection Size (PN 1.0-2.5MPa)
Nominal diameter DN | L | H | H1 | A | B |
50 | 250 | 335 | 90 | 170 | 170 |
65 | 280 | 345 | 98 | 180 | 180 |
80 | 310 | 355 | 110 | 190 | 190 |
100 | 350 | 365 | 120 | 200 | 200 |
125 | 400 | 445 | 145 | 215 | 215 |
150 | 450 | 460 | 155 | 230 | 230 |
200 | 550 | 505 | 190 | 255 | 255 |
250 | 650 | 550 | 250 | 295 | 295 |
300 | 800 | 710 | 290 | 325 | 325 |
350 | 900 | 725 | 330 | 380 | 380 |
400 | 1000 | 760 | 360 | 415 | 415 |
450 | 1000 | 810 | 445 | 435 | 435 |
500 | 1100 | 865 | 495 | 460 | 460 |
600 | 1100 | 935 | 550 | 520 | 520 |
700 | 1450 | 1000 | 605 | 570 | 570 |
800 | 1560 | 1100 | 730 | 620 | 620 |
900 | 1800 | 1205 | 800 | 670 | 670 |
1000 | 2000 | 1330 | 910 | 830 | 830 |