FilterTrak 660 sc ultra low range turbidity meter

Model
Nature of the Manufacturer
Manufacturer
Product Category
Turbidity Analyzer Product Center
Place of Origin
City, Province
Overview
FilterTrak 660 sc ultra low range turbidity meter
Product Details
typical application:
Filter membrane status monitoring in the membrane treatment process;
Turbidity monitoring of direct drinking water system;
Ultra-low-range turbidity monitoring of factory water from waterworks
 
Instrument characteristics
● The controller of FT660 sc is sc200 or sc1000 universal controller
● The sensitivity is increased to 150 times of the traditional turbidity meter, which can accurately measure the turbidity below 0.1NTU
● Patented built-in bubble removal system
● Use HACH to provide a standard turbidity sample 800mNTU calibration system
● LED laser light source, low power consumption, no stray light, stable light intensity
● Adopt HEPA 10133 method approved by USEPA
 
Measuring principle
The water sample passes through the defoamer. After the entrapped air bubbles are removed, it flows into the measurement chamber of the FilterTrak sensor through the center column. The 35mW laser diode emits a light beam with a wavelength of 660nm and passes through the sample cell. The beam is a highly calibrated monochromatic beam, eliminating stray light. After being scattered by the particles in the sample, the light is received by a monitor at a 90 ° angle to the beam and coupled to the detection system for analysis via an optical fiber. The amount of light detected is proportional to the turbidity of the sample.
Scan the QR code to read on your phone
Technical index
Range0.000-5000mNTU
light source660nm laser light source
Accuracy
0-1000mNTU, ± 3% of reading value or 5mNTU
1000-5000mNTU, ± 2% of reading
Resolution0.001mNTU
Reproducibility
Less than 1% at 24mNTU
± 1% at 500mNTU
± 1% at 800mNTU
Sample flow rate100~750mL/min
Operating temperature0~40℃
Water temperature0~50℃
Analog outputTwo 0/4 ~ 20mA, the output can be arbitrarily set in the range of 0 ~ 5000mNTU
connecting cables2m cable is included; if necessary, you can choose to extend the cable: 7.5m, 15m, 30m, 100m
Alarm OutputThree turbidity alarm points, each alarm point is equipped with SPDT relay, 5A / 230VAC

 