Welcome Customer !

Membership

Zealwe Technology Co,. Ltd.
Free Member ·1YRS
ShangHai,ShangHai
Manufacturer

Main Products: Aging Test Chamber

Xwboo>Products

Zealwe Technology Co,. Ltd.Free·1YRS

  • E-mail

    info@zealwe.cn

  • Phone

    86-21-54322103

  • Address

    No. 1288, Zhongchun Road, Minhang District, Shanghai

Contact Now

EL Tester

Model
Nature of the Manufacturer
Manufacturer
Product Category
PV Module Aging Test
Place of Origin
City, Province
Overview
EL Tester
Product Details

l The test area is 2100mm*1500mm, which suit for all the silicon cell module and thin-film module.

l Include bar-code scan function, the bar-code could display on the image.

l Able to set the voltage and current of the power source.

l The EL picture could be sort out and saved automatically with the name of the number of bar-code.

n a) Broken, cracked, or torn external surfaces.

n b) Bent or misaligned external surfaces, including superstrates, substrates, frames and junction boxes to the extent that the operation of the PV module would be impaired.

n c) Bubbles or delaminations forming a continuous path between electric circuit and the edge of the module.

n d) If the mechanical integrity depends on lamination or other means of adhesion, the sum of the area of all bubbles shall not exceed 1 % of the total module area.

n e) Evidence of any molten or burned encapsulant, back sheet, front sheet, diode or active PV Component.

n f) Loss of mechanical integrity to the extent that the installation and operation of the module would be impaired.

n g) Cracked/broken cells which can remove more than 10 % of the cell’s photovoltaic active area from the electrical circuit of the PV module.

n h) Voids in, or visible corrosion of any of the layers of the active (live) circuitry of the module extending over more than 10 % of any cell.

n i) Broken interconnections, joints or terminals.

n j) Any short-circuited live parts or exposed live electrical parts.

n k) Module markings (label) are no longer attached or the information is unreadable.

l The program automatically controls the current and module would not be loaded with the power, which could avoid voltage surge for the module.

l Temperature of Module could be monitored.

l Include tripod to set EL & Visual inspection camera.


Item

Parameters

EL Camera Resolution with SD card(3 Nikon camera)

16 million pixels for each camera, totally 48 million pixels

Power of the power supply

1500W

Voltage range

0-100V

Voltage accuracy

±0.5%

Voltage resolution

1V

Current range

0-15A

Current accuracy

≤0.5%

Current Resolution

0.1A

Module Temperature range

0-150℃

Module Temperature accuracy

1℃

Module Temperature repeatability

≤0.5℃