3. DETAIL SPECIFICATIONS:
Type:ZLQ22A-SWP11Z-DYG24V-S
Construction category: on-off
Operation method: Push button switch
Configuration: Single-Pole Double -Throw (SPDT)
Terminal form:Solder Terminal
Protection:IP67
Ratings 5A 250VAC
Withstand voltage 1000VAC,1Min
3.1 General
3.1.1 Application This specification is applied to ZLQ19 Power Switch used for electronic equipment.
3.1.2 Operating temperature range -20℃ to +55℃
3.1.3 Test conditions Unless otherwise specified. The atmospheric conditions for making measurements and tests are as follows
Ambient temperature:15~35℃
Relative humidity:45~85%
Air pressure: 86~106kPa (860~1060 mbar)
Should any doubt arise in judgment. tests shall be conducted at the following conditions.
Ambient temperature:20±2℃
Relative humidity:60~70%
Air pressure: 86~106kPa (860~1060 mbar)
3.2Appearance construction and dimensions
3.2.1Appearance Switch shall have good finishing, and no rust crack or plating failures.
3.2.2Construction and dimensions Refer to individual product drawing
3.3. Electrical Characteristics
NO. | Items | Test conditions |
3.3.1 | Contact resistance | The contact resistance should be 50mΩ(Max). |
3.3.2 | Insulation resistance | It is measured with 1000V DC 1minute should be 1000MΩ(Min). |
3.3.3 | Dielectric strength | AC 2000V,1min.(before endurance test) AC 2000V,1min.(after endurance test) |
3.4 Mechanical Characteristics
Item | Description | Test Conditions |
1 | Operating Force | 5N Max
|
2 | Operating Life | The mechanical life all of 50 000 cycles |
3 | Travel | 3.0mm |
3.5Durability
NO. | Item | Test condition | Criteria |
3.5.1 | Endurance (According to UL61058) | 5A 250VAC Switch shall be operated according to following sequence (Test1~Test2) | Voltage | Current | Power factor | Operation rate | Number of operation | Test1 | 250VDC | 5A | 0.75-0.8 | 6-10 cycles/min | 50cycles | Test2 | 250VDC | 5A | 0.75-0.8 | 6-10 cycles/min | 50000cycles |
Voltage proof(Cut-off current:0.5mA) 5A 250VAC Switch shall be operated 50,000 cycles at 15-20 cycles/min. Test voltages shall be applied for 1 min |
Insulation resistance(item 4.2): 50MΩ MIN Voltage proof: Terminal and ground:1000VAC No dielectric breakdown shall occur. Operating characteristic (item 5.1): Operating characteristic variety Within ±20% of specifiedvalue . 6000 cycles temperature rise:45℃MAX; 10,000 cycles temperature rise:55℃ MAX; No abnormalities shall be recognized in appearance and construction |
3.5.2 | Endurance (According to EN61058-1 /IEC61058-1) | 5A 250VAC Switch shall be operated 50,000 cycles at 15~20 cycles/min Voltage proof(Cut-off current:0.5mA) Test voltages shall be applied for 1 min. | Insulation resistance(item 4.2): 50MΩ MIN Voltage proof: Terminal and terminal:750VAC Terminal and ground:1500VACNo dielectric breakdown shall occur. Operating characteristic (item 5.1): Operating characteristic variety Within ±20% of specifiedvalue . Temperature rise:55℃ MAX No abnormalities shall be recognized in appearance and construction |
3.6. SOLDERING
Solder ability and Resistance to sold heat according to IEC 68-2-20
4. DRAWING & DIMENSION: