| Function Characteristics |
>Second generation of cs-20, better property. >Wide range, minute extension. >Used for the electronic platform scale,electronic ground scale and various dynamo metric apparatuses. Interchangeable and easy to install and put into use.
|
| |
| configuration: |
| Rated Load | Size mm | | Lb | t | Φ | R | L | H1 | H2 | Φ2 | | 5-10K | 2-5 | 34 | 16 | 64 | 32 | 19 | 106 | | 25-50K | 10-25 | 41 | 22 | 79 | 47 | 24 | 122 | | 100K | 50 | 51 | 22 | 88 | 51 | 29 | 143 |
|
| |
| Techincal Parameter |
| Sensitivity | 2±0.01mv/v 4.0±0.01mv/v | | Nonlinearity | ±0.03%FS | | Hysteresis | ±0.03%FS | | Repeatability | 0.01%FS | | Creep | ±0.02%FS/30min | | Zero balance | 2%FS | | Zero temperature coefficient | ±0.02%FS/10℃ | | Rated output temperature coefficient | ±0.02%FS/10℃ | | Output resistance | 700Ω | | Insulationg resistance | ≥5000MΩ | | Supply Voltage | 5~15V | | Temjperature compensation range | -10~+50℃ | | Safe temperature range | -30~+60℃ | | Safe overload | 130%FS | | Defend grade | IP66 | | Method of connecting wire | input:Red(+)Yellow(-) output:Blue(+)White(-) |
|