| FUNCTION CHARACTERISTICS |
>High accuracy , excellent reliability. >May replace the RTN of Shenke company sensor directly. >May be applied in the hopper balance and steel-coating balance. |
| |
| configuration: |

| Rated Load/mm | A | B | C | H1 | H2 | H3 | | 1~4.7 | Φ54 | Φ20 | Φ60 | 43 | 7.5 | / | | 10,15,22 | Φ75 | Φ30 | Φ75 | 50 | 6.5 | 7 | | 33 | Φ95 | Φ40 | Φ95 | 65 | 10 | 7 | | 47 | Φ130 | Φ60 | Φ130 | 75 | 14 | 7 | | 68 | Φ130 | Φ60 | Φ130 | 85 | 14 | 7 | | 100 | Φ150 | Φ70 | Φ150 | 90 | 16 | 7 | | 150 | Φ150 | Φ70 | Φ150 | 100 | 16 | 7 | | 220 | Φ225 | Φ100 | Φ225 | 130 | 24 | 10 | | 330 | Φ225 | Φ100 | Φ225 | 145 | 24 | 10 | | 470 | Φ270 | Φ120 | Φ270 | 170 | 28 | 10 |
|
| |
| Techincal Parameter |
| Sensitivity | 2.85mv/v | | Non linearity | 0.1%FS | | Hysteresis | 0.1%FS | | Repeatability | 0.05%FS | | Creep | ±0.1%FS/30min | | Creep recovery | ±0.1%FS/30min | | Zero baiance | 2%FS | | Zero temperature | <0.1%FS/10℃ | | Rated output temperature coefficient | <0.1%FS/10℃ | | Output resistance | 4000Ω | | Insuiation resistance | ≥3000MΩ | | Supply Voitage | 5~15V | | Safe temperature range | -30~+60℃ | | Safe overload | 150%FS | | Denfend grade | IP66 | | Method of connecting wire | input:Red(+)Yellow(-) output:Blue(+)White(-) |
|