Same features as the big brother XTM in a robust IP54 enclosure.
The XTS, part of the Xtender range, provides a great flexibility of use due to its many functions: bidirectional inverter; battery charger; transfer system, assistance to the source or feed back to the source, (Grid feeding).
These functions can be combined and controlled in a totally automatic way for an optimal management of available energy.
2 auxiliary contacts allow automatic control of a genset, second priority load disconnection or other programmable functions.
Product feature
• Robust IP 54 enclosure
• Electronically protected against reverse polarity
• Outstanding efficiency and overload
• Peak shaving with perfect power assist function
• Embedded basic settings for easy commissioning
• Extended setting, display; and data logging with RCC unit
• Parallel and/or three-phase setting up to 9 units
• Ultra-short transfer time (from 0 to 15ms max.)
• 2 programmable auxiliary contacts
• Web access through plug and play device Xcom-GSM/-LAN
Certificates
Compliant with European Standards (CE) RoHS compliant
SGS
ISO 9001
Made in China
Electronic protection functions
Deep discharge protection
Battery overvoltage shutdown
Short circuit protection
Overtemperature and overload protection
Reverse polarity protection by internal fuse
Acoustic alarm at deep discharge or overheating
Accessories
Remote control and display Fangpusun RCC-02
Remote control and display Fangpusun RCC-03
Battery temperature sensor Fangpusun BTS-01
Integrated cooling unit ECF-01
Communications cable
Fangpusun BSP 500/1200
Operation
Main switch
Adjustable load detection
Options
Type with 115 V/60 Hz
Model with protective lacquered mainboard
TECHNICAL DATA
Model
XTS900-12
XTS1200-24
XTS1400-48
Characterisation of the operating performance
Nominal battery voltage
12V
24V
48V
Input voltage range
9.5-17Vdc
19-34Vdc
38-60Vdc
Continuous power
650**/500 VA
800**/650 VA
900**/750 VA
Power 30 min.
900**/700 «
1200**/1000VA
1400**/1200 VA
Power 5 sec.
2.3 kVA
2.5 kVA
2.8 kVA
Max. efficiency
93%
93%
93%
Own consumption stand by
1.4W
1.5W
1.6W
Own consumption ON
7W
8W
8W
Acoustic level without ventilation
40 dB
Acoustic level with ventilation
45 dB
Maximum load
Up to short-circuit
Maximum asymmetric load
Up to Pcont.
Load detection (stand-by)
2 to 25 W
Cos (p
0.1-1
Output voltage
Pure sine wave 230Vac (?%)/ 120Vac (1)
Output frequency
45Hz - 60Hz (1) ?0.05% (crystal controlled)
Harmonic distortion
<2%
Overload and short-circuit protection
Automatic disconnection with 3 time restart attempt
Overheat protection
Warning before shut-off - with automatic restart
Battery charger
Charge Characteristic
6 steps : Bulk-Absorption-Floating-Equalization-reduced fl oating-periodic absorption Number of steps, threshol
ds, end current and times completely adjustable with the RCC-02/-03
Temperature compensation
With BTS-01 or BSP 500/1200
Power Factor Correction (PFC) according
EN 61000-3-2
Maximum charging current
35A
25A
12A
Input voltage range
150 to 265Vac / 50 to 140Vac (1)
Input frequency
45 to 65Hz
Input current max. (transfer relay) / Output current max.