Off grid solar power inverter Xtender XTH Hybrid Inverter/Charger
XTH 3000-12 from DC 12V to AC 230V or 120V 3000VA Inverter
XTH 5000-24 from DC24V to AC 230V or 120V 5000VA Inverter
XTH 6000-48 from DC48V to AC 230V or 120V 6000VA Inverter
XTH 8000-48 from DC48V to AC 230V or 120V 6000VA Inverter
Product features
● True sine wave voltage
● Excellent overload capabilities
● Optimal battery protection
● Adjustable integrated battery charger
● Multistage programmable battery charger with PFC
● Automatic load detection
● Parallel connectable
● Best reliability
● Multifunction contact
● Adjustable power sharing
● Standby load detection adjustable over a wide range, starting from a low value
The main function of the design XTH series Off grid solar power inverter as follows:
The Xtender series provides unmatched freedom of use due to its many functions. In a basic application, it offers a total package: the functions of inverter, battery charger, transfer system and assistance to the source These functions can be combined and controlled in a totally automatic way for exceptional ease and optimal management of available energy.
The Xtender is equipped with a command entry and 2 configurable auiliary contacts. This allows automatic control of a genset or loadshedding when the battery voltage is too low. The flexibility obtained makes it possible to implement special functionalities, often necessary for good energy management In standalone systems.
The Xtender series offers an optimal use of all sources that can be found in hybrid systems, whatever their connecting mode (AC or DC bus), up to the nominal power of the Xtender system (single, parallel and/or three phase).
Function Smart-Boost and active filtering
With this function it is possible to interact directly with the A source (Genset or grid) and to implement some basic functions such as:
● Efficient and immediate limitation of the current of the source, Including non linear or inductive/ capacitive loads, protecting efficiently the breakers during connection to shore power or to a camping power meter with limited current (function of power shaving and power assistance) (more information on our website and in the Application note AN001/www.fangpusun.com).
◆ Power shaving of load steps on the generator allowing an optimal sizing of the generator and assuring the best possible efficiency of the fossil fuels (function of filtering and of power assistance).
The function of assistance to the source enables also to implement advanced functions such as the priority use of renewable energy, even when the grid is available (more information on our website and in the Application note AN002Avww.fangpusun.com).
Features and performances
● Outstanding efficiency and overload.
● Perfect management and limitation of AC sources.
● Power shaving of the consumption peaks.
● Automatic allocation of available power.
● Active filtering of load steps on the genset.
● Automatic protection of the sources against overload.
● Battery priority (or to renewable sources).
● Parallel and three-phase setting, up to 9 units (72kVA).
● Powerful multi-stage PFC charger.
● Ultra-short transfer time (from 0 to 15ms max.).
● Automatic and efficient stand-by.
● 2 programmable auxiliary contacts (optional on the XTS).
● Compatible with AC coupling.
● XTS electronically protected against reverse polarity.
● Display, programming and data logging integrated
in the remote control (RCC).
● Interactive with the Battery Status Processor (BSP).
● RS-232 communication for remote supervision.
Electronic protection functions
Deep discharge protection
Battery overvoltage shutdown
Short circuit protection
Overtemperature and overload protection
Reverse polarity protection by internal fuse (except Fangpusun Xtender XTH 3000) Acoustic alarm at deep discharge or overheating
Displays
5 LEDs show operating states
The connection:
The data of the XTH series Xtender Inverter:
Model
XTH 3000-12
XTH 5000-24
XTH 6000-48
XTH 8000-48
Characterisation of the operating performance
Nominal battery voltage
12V
24V
48V
48V
Input voltage range
9.5-17VDC
19-34VDC
38-68VDC
38-68VDC
Continuous power
2500VA
4500VA
5000VA
7000VA
Power 30 min.
3000VA
5000VA
6000VA
8000VA
Power 5 sec.
7.5KVA
12KVA
15KVA
21KVA
Max.efficiency
93%
94%
96%
96%
Own consumption stand by
1.4W
1.8W
2.2W
2.4W
Own consumption ON
14W
18W
22W
30W
Acoustic level without ventilation
40 dB
Acoustic level with ventilation
45 dB
Maximum load
Up to short-circuit
Maximum asymmetric load
Up to Pcont.
Load detection (stand-by)
2 to 25 W
Cos p
0.1-1
Output voltage
Pure sine wave 230Vac (±2%)/120Vac(1)
Output frequency
45Hz-60Hz(1)±0.05%(crystal controlled)
Harmonic distortion
<2%
Overload and short-circuit protection
Automatic disconnection with 3 time restart attempt
Overheat protection
Warning before shut-off- with automatic restart
Battery charger
Charge Characteristic
6 steps: Bulk-Absorption-Floating-Equalization-reduced fl oating-periodic absorptionNumber of steps, thresholds, end current and times completely adjustable with the RCC-02/-03
Temperature compensation
With BTS-01 or BSP 500/1200
Power Factor Correction(PFC) according
EN 61000-3-2
Maximum charging current
160A
100A140A
120A
Input voltage range
150 to 265Vac/50 to 140Vac(1)
Input frequency
45 to 65Hz
Input current max. (transfer relay)/Output current max.
Xihe Electric is one of the leading China Xtender Inverter manufacturers, our factory is able to produce cheap off grid solar power inverter Xtender Inverter with reliable quality. Welcome to wholesale products from us.