Specifications |
PCL Electro- magnetic Flowmeter | Divided type | Integrated type (IP67) | Integrated type with explosion proof | Battery type | Heat (Energy) type |
Basic error | ±0.2% or ±0.5% of indicated value |
Diameter(mm) | DN15-DN2400 | DN15-DN600 | DN25-DN1400 |
Flange | Comply with GB9119 standard, Carbon steel (Stainless steel optional) |
Pressure level | DN15-DN600 1.0, 1.6, 2.5, 4.0MPa DN700-DN2400 0.6, 1.0, 1.6MPa | DN15-DN600 1.0, 1.6, 2.5, 4.0Mpa | DN15-DN600 1.0, 1.6, 2.5, 4.0MPa DN700-DN2400 0.6, 1.0, 1.6MPa |
| For special pressure please consult with the manufacturer. |
Lining material | PTFE, PU, CR, PFA, F46, IR |
Conductivity | ≥5uS/cm (For <5uS/cm please consult with the manufacturer) |
Electrode | 316L, Hastelloy, titanium, tantalum, platinum iridium alloy |
|
|
| Temperature sensor type: PT1000 |
Protection | IP67 (IP68 optional for sensor) | IP65, IP67 | IP65, IP67 | IP68 | IP67, IP68 |
Medium temp. | -25℃-180℃ (Refer to the choice of lining material.) | -25℃-80℃ (Refer to the choice of lining material.) | -25℃-180℃ (Refer to the choice of lining material.) |
Ambient temp. and the influence | -25℃-60℃ <±0.1%/10℃ or <±0.25%/10℃ |
Repetition | ≤±0.1%/, ±0.25% |
Analog output error | ≤±0.02mA |
Measuring range velocity | ≤20m/s |
Electrical connection | M20×1.5 seal, G1/2, NPT1/2 |
Output | Standard output (4-20mA), Pulse, RS485, HART, Profibus-PA
|