With reliable intelligent design, GS series solar inverter can be available to complicated appliances. Not only used for common appliances such as TV computer, lights, fans.but also suitable for inductive loadings such as refrigerators, airconditioners, motors, pumps compressors and laser printers.
Features:
GS Series AC/Solar charging Off grid Hybrid lnverter.
LED/LCD display,Enhanced functions setting via LCD,Man-machine intelligent design.
Built-in 60A optional MPPT solar charger controller.
LCD shows the solar capacity.
5 stages adjustable AC charging current. AC charging also can be closed.
AC/DC priority modes can be closed.
Generator restart signal(Dry contact).
3 times peak power.Strong loading capacity.
Overload,output short-circuit protection.
Specifications:
| Model | GS8000 | GS10000 | GS12000 |
| Power Rating | 8000W | 10000W | 12000W |
AC Input | Input Voltage Waveform | Sinusoidal(utility or generator) |
Nominal input Voltage | 230VAC |
Low Line Disconnect | 184Vac±4%(Normal) or 135Vac±4%(Wide) for 230Vac |
Low Line Re-connect | 194Vac±4%(Normal) or 145Vac±4%(Wide) for 230Vac |
High Line Disconnect | 263Vac±4%(Normal) or 263Vac±4%(Wide) for 230Vac |
Max AC input Voltage | 230Vac for Max270Vac |
| Frequency | 50Hz:41-54Hz,60Hz:51-64Hz |
| AC Charger | Nominal Charge Current | 20A/35A/50A/70A/90A(5 stages adjustable charging current) |
Over Charge Protection | Bat.VN62.0VDC for 48V battery ; beeps 0.5s every 1s & fault after 60s |
| Solar Charger | Rated Charge Current | 60A | 60A | 60A |
PV Input Voltage range | 55-145VDC for 48V |
Max.PV open circuit array voltage | 48V for 145VDC |
| Charger mode | MPPT |
PV Low Voltage Re-connect | PV>Bat.V=3V |
PV Low Voltage Disconnect | PVWBat.V |
| Efficiency | >97% |
| Charger | Nominal Charger Current | 20A/35A/50A/70A/90A(According to the inverter model), 5 stages adjustable charging current |
Over charge Protection | Bat.V>15.5VDC/31VDC/62VDC,beeps 0.5s every 1s & fault after 60s |
| Efficiency | Efficiency (Battery Mode ) | >87% |
Efficiency (Line Mode) | >98% |
| Battery Voltage | Nominal DC Input Voltage | 48VDC |
Low DC input shut-down | 40VDC±1.2VDC for48VDC |
High DC input Alarm & Fault | 64VDC±1.2VDC for48VDC |
| Transfer Time | AC to DC DC to AC | 20ms(max) 15ms(max) |
| System Parameter | Over-Load Protection | 110%150%, beeps 0.5s every 1 s, and Fault after 20s |
| Output Short Circuit Protection | Current limit(Fault after 10s) |
Surge Rating (10s) | 1:3(VA) |
| Power Saver | Load<25W(Enabled on "P/S auto"Setting of Remote control) |
| Protections | Low battery.over charging,over load,over temp |
| Indicators | LED+LCD Display |
| General Specification | Operating Temperature Range | 0°C to 40°C |
| Storage Temperature | -15°C 〜60°C |
| Operation humidity | 5% to 95%(non-condensing) |
| Audible Noise | 60dB max |
| cooling | Forced air,variable speed fan |
| Dimension(L*W*H) | 627*416*204mm |
| Net Weight(kg) | 52.5kg | 58.5kg | 66.5kg |