With reliable intelligent design, Gs series solar inverter can be available to complicated appliances. Not only used for common appliances such as TV computer, lights, fans.but also suitable for inductive loadings such as refrigerators, airconditioners, motors, pumps compressors and laser printers.
Features:
♦ GS Series AC/Solar charging Off grid Hybrid Inverter.
♦ LED/LCD display, Enhanced functions setting via LCD, Man-machine intelligent design.
♦ Built-in 40A/60A/120A optional MPPT solar charger controller.
♦ LCD shows the solar capacity.
♦ Adjustable 5 stagesAC charging current. AC charging also can be closed.
♦ AC/DC priority modes can be set.
♦ Generator restart signal. (Dry contact).
♦ 3 times peak power. Strong loading capacity.
♦ Overload, output short-circuit protection.
♦ Apply to Split Phase system,2 live lines 1 neutral line,voltage is 120/240V ,110v/220v or100v/200v
Specifications:
| Model | Parameters | GS1000 | GS2000 | GS3000 | GS4000 | GS5000 | GS6000 | GS8K | GS10K | GS12K |
| AC Input | Nominal Power | 1KW | 2KW | 3KW | 4KW | 5KW | 6KW | 8KW | 10KW | 12KW |
| Input Voltage Waveform | sinusoidal (utility or generator) |
| Nominal input Voltage | HOT1-HOT2: 240VAC |
| Low Line Disconnect | 180Vac±4%(Normal) or 140Vac±4%(V/4de) |
| Low Line Re-connect | 190Vac±4%(Normal) or 150Vac±4%(Wide) |
| High Line Disconnect | 270Vac±4%(Normal) or 270Vac±4%(Wde) |
| High Line Re-connect | 260Vac±4%(Normal) or 260Vac±4%(/A4de) |
| Max AC input Voltage | Max280V |
| Frequency | 50Hz:41-54Hz, 60Hz:51-64Hz |
| AC Output | Output Voltage Waveform | Sinewave |
| Power Factor | 1.0 |
| Nominal Output Voltage (V) | HOT1-N: 120Vac ±10%rms; HOT2-N: 120Vac ±10%rms; HO1-HOT2: 240Vac ±10%rms |
| output phase difference | HOT1-N and HOT2-N is 180°; HOT1-N and HOT1-HOT2 is 0°; HOT2-N and HOT1-HOT2 is 180° |
| Nominal Output Frequency (Hz) | 50Hz±1Hz,60Hz±1Hz |
| AC Charger | Nominal Charger Current | 20A/35A/50A/70A/90A(According to the inverter model): adjustable 5 stages charging current; |
| Over charge Protection | Bat.VN15.5VDC for 12V battery. Bat.VN31.0VDC for 24V battery、Bat.VN62.0VDC for 48V battery; beeps 0.5s every 1s & fault after 60s |
| Solar charger | Rated Charge Current | alternative 40A/60A/120A |
| FV Input Voltage range | 15VDC-40VDCfor 12VDC, 30VDC-75VDCfor 24V DC, 60-145VDCfor 48V |
| Max.FV open circuit array Voltage | 12V for 40Vdc, 24V for 75Vdc, 48V for 145Vdc |
| Charger mode | MFPT |
| FV Low Voltage Re-connect | FVNBat.V+3V |
| FV Low Voltage Disconnect | FVWBat.V |
| Efficiency | N97% |
| Battery Voltage | Nominal DC input Voltage | 12/24/48VDC | 24/48VDC | 48VDC |
| Low Battery Alarm | 10.5VDC±0.3VDC for 12VDC |
| | 21VDC±0.6VDC for 24VDC |
| | 42VDC±1.2VDC for 48VDC |
| Low DC input shut & down | 10VDC±0.3VDC for 12VDC |
| | 20VDC±0.6VDC for 24VDC |
| | 40VDC±1.2VDC for 48VDC |
| High DC input Alarm & Fault | 16VDC±0.3VDC for 12VDC |
| | 32VDC±0.6VDC for 24VDC |
| | 64VDC±1.2VDC for 48VDC |
| Efficiency | Efficiency(Battery Mode) | N87% |
| Efficiency (Line Mode) | >98% |
| Transfer Time | AC to DC | 20ms(max) |
| DC to AC | 15ms(max) |
| System Parameter | Over-Load Protection | 110% <><150%, 0.5s="" 1s="" beeps="" every="">150%, beeps 0.5s every 1s, and Fault after 20s<150%,>150%,>150%,> |
| Output Short Circuit Protection | YES |
| Surge Rating | 1:3( VA) |
| FV protections | Low battery, over charging, over load, over terrp |
| Indicators | LED+LCD Display |
| General Specifications | Operating Temperature Range | 0°C 〜40°C |
| Storage Temperature | -15°C〜60°C |
| Operation humidity | 5% to 95%(non-condensing) |
| Audible Noise | 60dB max | 80dB max |
| cooling | Forced air,variable speed fan |
| Dimension L*W*H(mm) | 480*336*190nm | 530*400* 190mm | 627*416*204nm |
| Net Weight(kg) | 24kg | 27kg | 30.5kg | 42kg | 46.5kg | 48.5kg | 64kg | 73g | 79kg |