RT series high frequency online UPS is specially designed for servers, data-center critical network devices, sensitive electronic equipment, telecom, bank, hospital, bureau, traffic, public security, ATM and so on.
RT series high frequency online UPS is specially designed for servers, data-center critical network devices, sensitive electronic equipment, telecom, bank, hospital, bureau, traffic, public security, ATM and so on.
Features:
*Output voltage, frequency parameter and bypass function can be set via the LCD display.
*LED +LCD display Detailed Real-Time UPS Status and parameters.
*True online double conversion technology with advanced microprocessor control
*Advanced MCU microprocessor control technology, ensure long life reliability.
*Rack mount 19”design to save space
*Excellent Protection against over voltage, over load, over current, over charge and so on.
*Input L and N lines reverse wiring detection, Auto start when AC back.
*DC start function, Input PFC revise function.
*Smart RS232 communication with monitoring software.
*Intelligent slot available for AS-400 Dry contact and SNMP card Remote control.
*Rack mount battery pack to extend backup time.
Specifications:
Model | RT1K-C | RT1KL-C | RT2K-C | RT2KL-C | RT3K-C | RT3KL-C | RT6K-C | RT6KL-C | RT10K-C | RT10KL-C |
Rated Power | VA/W | 1KVA/800W | 1KVA/800W | 2KVA/1600W | 2KVA/1600W | 3KVA/2400W | 3KVA/2400W | 6KVA/4800W | 6KVA/4800W | 10KVA/8KW | 10KVA/8KW |
Input | Phase | Single Phase with Ground |
Nominal Voltage | 200/208/220/230/240VAC |
Voltage Range | 110 ~ 300VAC | 120~ 275VAC |
Frequency Range | 50Hz:46 ~ 54Hz 60Hz:56 ~ 64Hz | 40 ~ 70Hz |
Power Factor | 0.98 | 0.99 |
Connection | IEC320-10A inlet | IEC320-16A inlet | Terminal Block |
Output | Phase | Single Phase |
Voltage | 200/208/220/230/240VAC ± 1% |
Frequency | 50/60Hz adjustable,46~54Hz (Line mode) |
50Hz ± 0.2%Hz ( Battery mode) 60Hz ± 0.2%Hz ( Battery mode) |
Waveform | Pure Sine Wave |
Overload Capability | 105%~150% 45S~25S then turn to bypass output ; 150%~200% 25s~300ms then turn to bypass output; ≥200% 200ms then turn to bypass output. | Load﹤105% work consistant;105%﹤load﹤125% 1min;125%﹤load﹤150% 30sec |
Current Crest Ratio | 3:1 |
Connections | IEC320 -10A * 6 | IEC320 -10A *6 | IEC320 -10A * 8 | IEC320 -10A *8 | IEC320 -10A *8 | IEC320 -10A *8 | Terminal Block |
Bypass | Automatic Transfer | on overload and UPS failure |
Before UPS Power-on | Default “ON”, user adjustable to “YES” | Yes |
Transfer Time | 0 ms; less than 4 ms from inverter to bypass and vice versa | Zero |
LCD+LED display | UPS status, Battery capacity, loading, Fault code |
Audible Alarm | Bypass, On battery mode, Battery low, Overload, Fault |
Communications | Intelligent RS232 serial port: Software support Windows family software, Linux, Sun network operating system, IBM Aix, Compaq True64 SGI IRIX, FreeBSD, HP-UX and MAC |
SNMP(Optional) Remote control UPS through SNMP management and Internet |
USB(Optional) Windows family software and Mac OS |
Network Surge Protection | RJ45 I/O port available for network or Fax/Modem |
Environmental | Operating Temperature | 0 ~ 40°C |
Operating Humidity | 20 ~ 90% non-condensing |
Main Unit | NetWeight(Kg) | 11.00 | 7.50 | 8.50(2U) | 8.90 | 10.00(2U) | 10.50 | 13.80 | 14.30 | 15.10 | 15.80 |
Dimensions (LxWxH) mm | 440*375* 89 (2U) | 440*438* 89 (2U) | 440*438* 89 (2U) | 440*438* 89 (2U) | 440*438* 89 (2U) | 520*440*134(3U) |
Battery Pack | Type | Internal Batteries | External Battery Pack | External Battery Pack |
Nominal DC Voltage | 24VDC | 36VDC | 48VDC | 48VDC | 72VDC | 96VDC | 192VDC |
Battery Numbers & Capacity | 2pcs *12V 9AH | External Battery Pack | 4pcs *12V 9AH | External Battery Pack | 6pcs *12V 9AH | External Battery Pack | 16pcs *12V 7AH | External Battery Pack | 16pcs *12V 7AH | External Battery Pack |
Backup Time (Full load) | 5 min | Depending on the capacity of external battery packs | 9 min (with 1 BP) | Depending on the capacity of external battery packs | 5 min (with 1 BP) | Depending on the capacity of external battery packs | 4 min | Depending on the capacity of external battery packs | 3 min | Depending on the capacity of external battery packs |
|
Recharge Time | 5hrs to 90% | 5hrs to 90% | 5hrs to 90% | 7hrs to 90% | 7hrs to 90% |
Charging Current (Max.) | 1.0A | 5A/7A±1A | 1.0A | 5A/7A±1A | 1.0A | 5A/7A±1A | 1.0A | 4.5A | 1.0A | 4.5A |
Charging Voltage | 27.4VDC±0.2 | 41.4VDC±0.4 | 54.8VDC±0.4 | 54.8VDC±0.4 | 82.2VDC±0.6 | 110VDC±0.4 | 218.40VDC±2 |