Butadiene PVC Compound Soft Cable
It is used for supervising and controlling return circuit of A.C. rated voltage of 450/750V or lower, power connection of various electrical equipments, radio devices, and lighting & protection under low temperature.
Executive standard: enterprise standard and JB1170-75 standard
Working condition
- Long-term working temperature of wire conductor is no more than 180℃ for cable with silicon insulation, 70℃ for that with PVC insulation
- Min. environment temperature of wire is -40℃
- Bending radius allowed by wire is no less than 8 times that of cable O.D OR 6 times for cable with soft structure.
Type and Description
Type | Cable description | Note |
| YVFR | Soft power cable with Cu core, butadiene PVC insulation and sheath | If thin-plated copper wire braided shielding is needed, the letter “P” in the original type of cable shall be changed into the letter “P1”. If thinned copper wire conductor is used, the relevant description shall be made in the order, but it is not necessary to give other description in cable type |
| YVFB | Flat type soft power cable with Cu core, butadiene PVC insulation and sheath |
| YGVFB | Flat type soft power cable with Cu core, silicon rubber insulation and butadiene PVC sheath |
| KVFR | Soft control cable with Cu core, butadiene PVC insulation and sheath |
| KVFRP | Soft control cable with Cu core, butadiene PVC insulation and sheath, copper wire braided shielding |
| KVFB | Flat type soft control cable with Cu core, butadiene PVC insulation and sheath |
| KGVFB | Flat type soft control cable with Cu core, silicon rubber insulation and butadiene PVC sheath |
Main Technical Parameter
- Max. DC resistance of conductor at 20℃ shall meet the requirement of the following table
| Nominal cross section area (mm2) | Conductor structure Pieces/diameter (mm) | Conductor DC resistance at 20℃≤Ω/km |
| Not tinned | tinned |
| 0.5 | 16/0.20 | 39.0 | 40.1 |
| 0.75 | 24/0.20 | 26.0 | 26.7 |
| 1.0 | 32/0.20 | 19.5 | 20.0 |
| 1.5 | 30/0.25 | 13.3 | 13.7 |
| 2.5 | 49/0.26 | 7.98 | 8.21 |
| 4 | 56/0.30 | 4.95 | 5.09 |
| 6 | 84/0.30 | 3.30 | 3.39 |
| 10 | 84/0.40 | 1.91 | 1.95 |
| 16 | 110/0.43 | 1.21 | 1.24 |
| 25 | 170/0.43 | 0.78 | 0.795 |
| 35 | 240/0.43 | 0.554 | 0.565 |
| 50 | 342/0.43 | 0.386 | 0.393 |
| 70 | 482/0.43 | 0.272 | 0.277 |
| 95 | 654/0.43 | 0.206 | 0.210 |
| 120 | 827/0.43 | 0.161 | 0.164 |
| 150 | 1033/0.43 | 0.129 | 0.132 |
| 185 | 1274/0.43 | 0.106 | 0.108 |
- Finished control cable shall bear A.C. test voltage of 3000V under power frequency for 5 min without puncture of insulation
- Finished power cable shall bear A.C. test voltage of 3500V under power frequency for without puncture of insulation