Welcome Customer !

Membership

Anhui Electric Group Shares Co.,Ltd.
Free Member ·1YRS
ChuZhou,AnHui
Manufacturer

Main Products: Power Cable|Control Cable

Xwboo>Products

Anhui Electric Group Shares Co.,Ltd.Free·1YRS

  • E-mail

    info@ahecable.com

  • Phone

    86(550)7309278

  • Address

    28,Tiancha Road,Economic Zone Tianchang,Anhui,P.R.China

Contact Now

Silicon Rubber (flame retardant) Control Soft Cable

Model
Nature of the Manufacturer
Manufacturer
Product Category
SPECIAL CABLES
Place of Origin
City, Province
Overview
Silicon Rubber (flame retardant) Control Soft Cable
Product Details
 It is widely used for supervising and controlling return circuit of rated voltage 450/750V or lower for production under high temperature in the field of steel & iron, refinery, power plant, coking plant, aviation, metallurgy, machinery, petrochemical industry etc. It has good feature of high temperature resistance, flame resistance, radiation resistance, aging resistance, ozone resistance, water proof, freezing resistance and weather resistance.

Executive standard: enterprise standard

Type, description and main application occasion listed in the following table


Type

Description

Main application occasion

(ZR)-KGG

Control cable with Cu core, silicon rubber insulation and sheath

To be fixedly laid indoor, in cable furrow or pipe

(ZR)-KGGP

Control cable with Cu core, silicon rubber insulation and sheath, braided shielding

Fixedly laid indoor, in cable furrow or pipe with demand on shielding

(ZR)-KGGP2

Control cable with Cu core, silicon rubber insulation and sheath, copper tape shielding

Fixedly laid indoor, in cable furrow or pipe with demand on shielding

(ZR)-KGGR

Control soft cable with Cu core, silicon rubber insulation and sheath

To be laid indoor or in the environment with demand on softness and mobility

(ZR)-KGGRP

Control soft cable with Cu core, silicon rubber insulation and sheath, braiding shielding

To be laid indoor or in the environment with demand on softness and shielding

Cable structure as follows


Type

Rated voltage

Nominal cross section area of conductor

0.5

0.75

1.0

1.5

2.5

4

6

10

Core number

KGG, KGGP, KGGP2

450/750

2~61

2~14

2~10

KGGR, KGGRP

4~61

4~48

2~14

Technical Parameter

    • Insulated resistance of finished cable insulated conductor will be no less than 50M under the condition that cable length is 1km and temperature is 20℃
    • Finished cable shall bear AC voltage test of 3000V under power frequency for 5 minutes without puncture of insulation