Computer Shielding Cable (Cable for DSC System)

Model
Nature of the Manufacturer
Manufacturer
Product Category
POWER CABLES
Place of Origin
City, Province
Overview
Computer Shielding Cable (Cable for DSC System)
Product Details

It is used as connection cable of inspection devices and instruments with high demand on interference resistant performance in computer network and control system.
Executive standard:
Q/AE.J.04.030-2004 or BS5308 standard for reference
Performance for Usage:
1. AC rated voltage U0/U: 300/500V. Long term working temperature of cable conductor is 70℃ & 105℃ for cable with PVC insulation, 70℃ for cable with PE insulation and 90℃ for cable with XLPE insulation.(XLPE insulation includes silane XLPE & irradiation XLPE insulation.)
2. Min. environment temperature is -40℃ for fixed laying and -15℃ for non-fixed laying. Environment temperature shall be no less than 0℃ for installing.
3. Min. bending radius allowed by cable is no less than 6 times that of cable OD for non-armored soft cable or braided shielding cable and 12 times that of cable OD for cable with metallic tape wrapped shielding or steel wire/steel tape armor.
Type, Description and Definition
Example: DJYP3VP3-32
32: Steel wire winding armor PVC outer sheath
P3: Aluminum-plastic compound tape wrapped general shielding 
V: PVC inner sheath
P3: Aluminum-plastic compound tape wrapped individual shielding
Y: PE insulation
DJ: Series number of computer cable
Main Technical Parameter

  1. DC Resistance of Conductor at 20℃

Nominal cross section area (mm2)

Pieces of conductor/diameter of single piece

DC resistance of conductor at 20℃

A

B

C

A, B

R

0.5

1/0.80

7/0.30

16/0.20

≤36.0

≤39.0

0.75

1/0.97

7/0.37

24/0.20

≤24.5

≤26.0

1.0

1/1.13

7/0.43

32/0.20

≤18.1

≤19.5

1.5

1/1.38

7/0.52

30/0.25

≤12.1

≤13.3

2.5

1/1.78

7/0.68

49/0.25

≤7.41

≤7.98

2. Insulation Resistance at 20℃


Performance item

PVC insulation

PE, XLPE insulation

Insulation resistance at 20℃

≥25

≥500

3. Cable shall endure A.C. voltage test of 2000V under power frequency for 1min without puncture of insulation. And testing temperature is environment temperature.