Walk in climatic chamber was widely used for large components, assemblies, and finished products.both Panel Walk-In Chambers and Solid Walk-In Chambers available.
Walk in chambers
Application:
KOMEG Walk In Chamber serves as a test site for large components, assemblies, and finished products. KOMEG manufactures both Panel Walk-In Chambers and Solid Walk-In Chambers and can be configured as a temperature chamber or a temperature humidity chamber.
A Panel Walk-In Chamber is made from lightweight insulated panels for fast and easy installation. Usually for electronics temperature aging, like recharger, PCBA, Battery, LCD, scanners, monitors, LED, biological equipment,etc. Outside banding helps prevent leaking and keeps moisture out of the Walk-In Chamber and workspace temperatures steady.
Solid Walk-In Chambers are custom built to accommodate almost any size. They feature welded walls creating an environmental room for applications requiring controlled temperature and humidity testing exceeding 85°C. Typically, for ease of installation, a Solid Walk-In Chamber works best in new construction buildings, areas with extremely large doors, or rooms where outside walls can be easily removed.
Standard Met and Implemented:
GB/Bb T2423.2-89 high temperature test method
GB2423.1-89 test A: low temperature test method 6
GJB150.4-1986 test at low temperature
IEC60068-2-1 low temperature test method
IEC60068-2-38 temperature cycle
IEC60068-2-78 constant humidity temperature
Main Technical Index |
1. Body |
1.1 Workplace volume | IW 1500 × IH 1500 × ID 1500 mm Inner volume: about 3.375m3 |
1.2 External dimensions | Depend on design |
2. Temperature |
2.1 Temp. range | -70℃ ~ +150℃ |
2.2 Temp. deviation | ≤±2℃ (without load) |
2.3 Temp. fluctuation | ≤±0.5℃ (without load) |
2.4 Temp. uniformity | ≤2℃ |
2.5 Ramping and soaking rate | +20℃ ↓ -70℃ temperature change rate ≥ 1.5℃/min (no load)-70℃ ↑ +100℃ temperature change rate ≥ 2.5℃/min (no load) |
Optional accessories
Cable Port: Two size of cable port is available: Φ50mm, Φ100mm.
Double door
Pass room: Provided to avoid disturbance of atmospheric temperature
and humidity while opening the door.
Floor reinforcement: Can be fixed if heavy specimen placed in the
chamber for test.
Carry-in inclined platform: Provided below the door to facilitate moving
of specimens in and out through the door.
Entire ceiling blow-out duct
The extremely wide air inlet reduces the airflow rate (down to
apprrox.0.5m/s)
Dehumidifier
The rotation regenerating dehumidifier (M-300)ensures precise control of
low humidity (21℃,23%RH)for electrostatic reliability tests.
Temperature and humidity recorder
100mm width recording paper with 6 dots
180mm width recording paper with 12 dots
Status indication lamp
Provide to signal chamber status and warnings when normal running,
a malfunction running or stand by occurs.
Water purifier
Provided to keep the humidifier heater free from scale and ensure the
supply of water to humidifier.
Power socket
Air cooled type condense