KF200 Laser Gas Analyzer

Model
KF200
Nature of the Manufacturer
Manufacturer
Product Category
KF200 Laser Analyzer
Place of Origin
City, Province
Overview
KF200 Laser Gas Analyzer
Product Details

The KF200 Series Laser Gas Analyzer is developed aiming at industrial on-line analyzing, and online environmental monitoring. Based on the semiconductor laser absorption spectroscopy (DLAS) technology, it is developed with features of an integrated design and high level of integration.

With various types of the KF200 series laser gas analyzer, including in-situ probing type, by-pass type, multi-channel and disc-mounted type, etc., gases like O2, CO, NH3, CO2, CH4, H2O, HC, HF, etc., can all be analyzed. The concentration analyzing of target gases includes the macro-analysis and micro-analysis.


Technical Principle:


Modulate laser (tunable) wavelength by using the current and temperature to scan the specific absorption peak of the measured gas (no background gas absorption), and then get the second harmonic of the gas absorption. By using the second harmonic information and the broadening of the gas, the concentration of the gas can be calculated.

未标题-1Technical Characteristics:

l The TDLAS technology is adopted for in-situ online gas analyzing;

l Double-proof probe design negates positive pressure purge, with no additional data processing unit, a simple compact structure and high reliability;

l Using high-power lasers, no fibre coupling, suitable for harsh working conditions (such as excessive dust);


Technical Specifications:

Technical Data

linearity error

≤ ±1% F.S.

Span drift

≤ ±1% F.S./6 months

Repeatability

≤ 1%

calibration period

≤ 1 time/6 month

Explosion-proof Grade

Ex d IIC T6

 Protection levels

IP66

Response Time

Warming-up time

≤ 15 min

Response time(T90)

≤ 1 s

Interface Signals

Analogue outputs

2-wire 4–20 mA signal input (Isolated, Max. load 750 Ω)

Relay output

3-wire relay (24 V,1A)

Digital Communication

RS485/RS232/GPRS

Analogue inputs

2-way 4–20 mA input (temperature-pressure compensation)

Laser Safety Standard

GB7247.1-2001 (idt IEC 60825-1:1993)

Operating Conditions

Storage Temperature

-30℃ ~ +60℃

Ambient temperature

-40℃ ~ +80℃

EMC

IEC 6100-4-2, IEC 6100-4-3, IEC 6100-4-4, IEC 6100-4-5,IEC 6100-4-11

Gas jet

0.3 ~ 0.8 MPa industrial nitrogen inlet and purification instrument gases, etc.

Consumption

< 20 W

Power

24 V DC (18-36 V DC), 220 V AC



Gas Detection Limits:


Detection Gas Type

Detection Limit

Detection range

O2

0.01% Vol.

(0-1)%Vol., (0-100)%Vol.

CO2

10 ppm

(0-1000)ppm,(0-100)%Vol.

H2S

20 ppm

(0-2000) ppm, (0-100)%Vol.

HCl

0.1 ppm

(0-50) ppm,(0-100)%Vol.

NH3

0.1 ppm

(0-10) ppm, (0-100)%Vol.

C2H2

0.1ppm

(0-10) ppm, (0-100)%Vol.

CO

10 ppm

(0-1000) ppm, (0-100)%Vol.

H2O

0.3 ppm

(0-50) ppm, (0-100)%Vol.

HF

0.02 ppm

(0-5) ppm, (0-10000) ppm

HCN

0.3 ppm

(0-30) ppm, (0-1)%Vol.

CH4

0.4 ppm

(0-40) ppm, (0-100)%Vol.

C2H4

0.6 ppm

(0-60) ppm, (0-100)%Vol.


Note: 

1) The test conditions include a 1-meter optical path, 1 bar gas pressure, and a 300 K gas temperature.

2) Increasing the optical path will proportionally lower the detection limit.