| data |
| General Specifications |
| Sensing distance: 30…400mm |
| Adjustment range: 50…400mm |
| Unusable area: 0…30mm |
| Standard target plate: 100mm×100mm |
| Transducer frequency: About 310 kHz |
| Response delay: About 50ms |
| Indicators/Operating means |
| LED blue Power on |
| LED yellow indication of the switching state Flashing:program function object detected |
| LED red permanently red: Error Red,flashing:program function,object not detected |
| Electrical specifications |
| Operating voltage UB10…30VDC,ripple10%ss |
| No-load supply current: ≤30mA |
Input |
Input type 1 TEACH-IN input Operating distance, A1:-UB…+1V,operating distanceA2:+6… + UB Input impedance:>4.7KΩ TEACH-IN programmable pulse :≥1S |
| Output |
| Output type : 1 switch output E5, NPN NO/NC, programmable |
| Rated operational current 100mA,Short circuit/overload protected |
| Default setting switch point A1:70mm Switch point A2:800mm |
| Repeat accuracy : ±0.1% of full-scale value |
| Voltage drop ≤ 3 V |
| switching frequency ≤ 8Hz |
| Range hysteresis 1% of the set operating distance |
| Temperature influence: ±1.5% of full-scale value |
| Ambient conditions |
| Ambient temperature: -25…70°C(-13 ... 158 °F) |
| Storage temperature: -40…85°C(-40 ... 185 °F) |
| Mechanical specifications |
| Protection grade: IP67 |
| Connection: V1 Connector M12x1,4-PIN |
| Material Housing: brass,nickel-plated |
| Transducer epoxy resin/hollow glass sphere mixture; Polyurethane foam |
| Weight 25g |
| Compliance with standards and di |
standard conformity EN60947-5-2:2007 IEC60947-5-2:2007 |