| data |
| General Specifications |
| Sensing distance: 50…800mm |
| Adjustment range: 70…800mm |
| Unusable area: 0…50mm |
| Standard target plate: 100mm×100mm |
| Transducer frequency: About 255 kHz |
| Response delay: About 100ms |
| Indicators/Operating means |
| LED green Power on |
| LED yellow indication of the switching state Flashing:program function object detected |
| LED red permanently red: Error Red,flashing:program function,object not detected |
| Electrical specifications |
| Operating voltage 10…30VDC,ripple10%ss |
| No-load supply current: ≤20mA |
Input |
Input type 1 program input Operating distance 1: -UB ... +1 V, operating distance 2: +6 V ... +UB input impedance: > 4,7 kΩ program pulse: ≥ 1 s |
| |
| Output |
| Output type : 1 switch output E5, PNP NO/NC, programmable |
| Rated operational current 200mA,Short circuit/overload protected |
| Default setting switch point A1:70mm Switch point A2:800mm |
| Repeat accuracy : ±0.1% of full-scale value |
| Voltage drop ≤ 3 V |
| switching frequency ≤ 4Hz |
| Range hysteresis 1% of the set operating distance |
| Temperature influence: ±1.5% of full-scale value |
| Ambient conditions |
| Ambient temperature: -25…70°C(-13 ... 158 °F) |
| Storage temperature: -40…85°C(-40 ... 185 °F) |
| Mechanical specifications |
| Protection grade: IP67 |
| Connection: V1 Connector M12x1,4-PIN |
| Material Housing: brass,nickel-plated |
| Transducer epoxy resin/hollow glass sphere mixture; Polyurethane foam |
| Weight 60g |